21.08.2015 Views

T E N D E R F O R M

maharashtra animal& fishery sciences university,nagpur

maharashtra animal& fishery sciences university,nagpur

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

continuously in ambient temperature of 10 -40 0 C and RHof 15-90%.Shall meet general Requirements of Safety forElectromagnetic Compatibility; System should haveMultichannel & Multifunction control with accuracy andease of operation; Method / Programme: can be developed,stored, recalled and run with simple keyboard operationFacility for the storage of at least 9 method files. Eventcontrols, Auto diagnostics and with valid interface for DataCommunication should be provided. Automatic GasSampling Valve, Column Oven with built in overheatprotection:Make: Perkin Elmer, Shimathzu, Thermo, Varian, Waters,Dionex, Agiland, Duoflow or any standard make.17. Polarimeter (i) Optical Rotation measurements (ii) Specific Rotation(iii) Concentration, Range : +/- 89 DegArc Resolution : 0.001 Deg Arc, Accuracy : 0.002 Deg Arcupto 1 Deg, Prism : Glan-Thomson PrismPreferred Wavelengths : Selectable from instrumentkeypad; Changeover of one Wavelength to another; LightSource : Tungsten-Halogen lamp; Sample Chamber : 100-200 mm sample tubes; Automatic Calibration via touchscreen; Display : LCD screenDetector : suitable as per requirementoutput. Should be capable of measuring samples upto 4.0OD. Make: Perkin Elemer, Shimatzu, Oxford, Antonpar,any Standard make.18. Heat StabilityApparatus19. Solid phaseextraction unitSize of chamber: 18"x14"x8"; Temp. Range:- 50 to 250deg.; Fitted with electronic temp. Controller cum indicatorwith digital display with ± 2 Deg Centigrade accuracy,Inner chamber made of SS White enamal paint Chamberhas provided 24 Heat Stability tubes to determine stabilitytest of milk grease.The chamber is filled with paraffin oil.Complete with 24 tube stirrer diffuser shelves to work on230 Volts A/C 50Hz. Complete with shaker oscillationdevice with 5 RPM. Make:- Labotech, Akash Deep Plt.Any standard makeSPE Vacuum Manifolds, 12-Port and 24-Port Models,Vacuum Bleed Valve, Stand-Alone Manifold Cover,Complete unit with all accessories20. Ultra Sonicator Equipment comprising of generator, ultrasonic converter,horn, tips/ probes, power cables; Output frequency 20 KHz(lower or higher); Electronic control of the ultrasonicgenerator; Continuous processor or on/off pulsingTemperature monitoring to prevent overheating of thespecimen; Programmable timer; Volume of 5 to 900 ml;OneOneOneOne17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!