21.08.2015 Views

T E N D E R F O R M

maharashtra animal& fishery sciences university,nagpur

maharashtra animal& fishery sciences university,nagpur

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

13. Inert gas weldingkit14. Power Generator/UPS (5 KV)15. Falling BallViscometerMembrane, muds separation. Overflow for the outlet offiltered water. Valve on the bottom for mud extraction.Dimensions: 800 x 600 x 700 mm.(variable), Make: Anystandard makeFor Students’ Training Dairy Workshop, With TIG Torch3 meter welding cable with holder, 2 met. Earthing cablewith clamp. Inclusive of gas cylinders,Make: Any standard makeCap. 5 KVAMake: Kirloskar, Microtek, Okaya, Chetak, SuKam/ Anystandard makeShould be fitted for precise measurement of the dynamicviscosity of clear liquids such as milk and milk products,fruit juices, Foods etc., Viscosity range 0.5 mPa To 70,000mPa.S; Accuracy : 0.5 - 2.0% depending on choice of ball.Ball Diameter 11.0 mm to 15.81 mm. Full time of ball inmeasurement: 30 to 300 second (Variable) OperatingTemp: -60C to 150 C Includes Calibrated ball sets, Controlthermometer (0 - 100 C) tweezel Tool cleaning brush forsample tube brush for dusting off calibrated ball set ofseals (5) test certificate operation manual. Instrument Case.System should have Circulator for external & internalheating & cooling, Power supply:Make: Brookfield, Hoppler, or any standard make.16. GLC Unit Fully Automatic Microprocessor controlled GC withextensive self-diagnostic facility, Flame out test should bepresent, Auto adjustment of carrier gas flow to compensatefor variations in ambient temperature and pressure,Programmable should be available to avoid sampledegradation or decomposition, Should have up gradationfacility.; OVEN: Temp.Range:5°C above Ambient -500°C, Heating Rate: :50°C - 250°C in 4 minutes, CoolingRate: :400°C - 50°C in 5.0 minutes, Oven Rate: :0.1 -45°Cmin. increment 0.1°C, Column Overhear Spectrometer;capability of installing 2 packed columns Should have dualchance background correction facility.; INJECTORS: Max4 injectors should be mount Temp. Range 50°C to 450°Cin 1°C increment, Built up Trap in split vent, Easyadjustment of split ratio, Septum range facility.;Programmable Split Splitless Capillary Column Injector;Should have Multi technique data handling system. CGLPoriented record keeping and reports, security, softwarevalidation certificate and instrument and sequence logsalongwith audit train software.; The unit shall be capableof being stored continuously in ambient temp.of 0 -50 0 Cand RH of 15-90%.; The unit shall be capable of operatingOneOneOneOne16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!