POWERGUIDE4400SPECIFICATIONSMeasured Parameters(4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg,256 samples/cycle, 16 b<strong>it</strong> ADC(4) inputs w<strong>it</strong>h CTs 1-6000 Arms, CT-dependent, AC/DC,256 samples/cycle, 0.1% rdg + CTs, 16 b<strong>it</strong> ADCFrequency range, 10 mHz resolution, 45-65 HzPhase Lock Loop - Standard PQ modeMon<strong>it</strong>oring/ComplianceIEEE 1159IEC 61000-4-30 Class AEN50160 Qual<strong>it</strong>y of SupplyCurrent Inrush/ EnergizationVoltage Fault RecordingLong Term Mon<strong>it</strong>oring w/min/max/avgContinuous Data LoggingPower Qual<strong>it</strong>y TriggersCycle-by-cycle analysis256 samples/cycle; 1/2 cycle RMS stepsL-L, L-N, N-G RMS Variations: Sags/swells/interruptionsRMS Recordings V & I (32 pre-fault, 10K post-fault cycles)Waveshape Recordings (32 pre-fault, 10K post-fault cycles)Low and Medium Frequency Transients - V & IHarmonics Summary ParametersCross trigger V & I channelsRMS Event Characterization (IEEE or IEC)Distortion/Power/EnergyW, VA, VAR, TPF, DPF, Demand, Energy, etc.Harmonics / Interharmonics per IEC 61000-4-7THD/Harmonic Spectrum (V,I,W) to 63rdTID/Interharm. Spectrum (V,I) to 63rdFlicker per IEC 61000-4-15 (Pst,Plt,Sliding Plt)Crest Factor, K Factor, Transformer Derating Factor,Telephone Interference FactorAvailable LanguagesEnglish, French, Italian, German, Spanish, SwedishGeneral SpecificationsSize (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3cm)Weight: 3.8 pounds (1.8 kg)Operating Temperature: 0º to 50º C (32º to 122º F)Storage Temperature: -20º to 55º C (4º to 131º F)Humid<strong>it</strong>y: 10 to 90% non-condensingSystem Time Clock: Crystal controlled, 1 second resolutionCharger /Battery Eliminator: 90-264 VAC 47-63 HzDisplay: LCD color touch screenMemory options (must have one): 32M-128M removablecompact flashcardOptional AccessoriesCurrent Probes: An extensive selection, including:Model TR-2510A 0-10 A; up to 0.47" conductorsModel TR-2500A 10-500 A; up to 1/8" diameteror 2.5"x 0.2"conductorsModel TR-2520A 300-3000 A; up to 2.56" diameter or1.97" x 5.3" (bus bar)Model TR-2019B 1-300 A; up to 2.0" conductors(requires 116002-G1 adapter)Flexible probes: ranging in current from 30-6000 A,24", 36", 48"Hall Effect Probes for AC/DC applications, 150 A or 1500 ACT Cable Adapter (CA4300LEM)Voltage Cable Accessory Pack (VCP4300)Soft Carrying Case (SCC-4300)Field Replaceable Battery Pack (BP-PX5)External Battery Charger (XBC-PX5)Reusable Shipping Container (RSC-4300)Weatherproof Container (NEMA4300)Lockable Portable Case (LPC-4300)Portable Field Printer (PFP4300)Communications Interface:RS232 FiberOptic Adapter (COMM-RS232)USB FiberOptic Adapter (COMM-OUA)LAN-FiberOptic Adapter (COMM-OEA)DRAN-VIEW software: Runs under Windows 98, ME, NTand XPNodeLink ® w<strong>it</strong>h <strong>download</strong>, setups and meterCD-ROM Training ProgramPOWERGUIDE4400Power Qual<strong>it</strong>y Analyzerdranetz-bmi.com1.800.372.6832 sales@dranetz-bmi.comtel 732.287.3680 • fax 732.248.1834 • 1000 New Durham Road • Edison, New Jersey 08818 USAPowerGuide, NodeLink and DRAN-VIEW are trademarks of <strong>Dranetz</strong>-BMI. ©2003 <strong>Dranetz</strong>-BMI. All rights reserved.Printed in the Un<strong>it</strong>ed States. Specifications are subject to change w<strong>it</strong>hout notice.www.dranetz-bmi.com“Out of the Box and Ready To Go,”3-phase, 8-channelPower Mon<strong>it</strong>oring Instrument


Equipped w<strong>it</strong>h 8 independent channels, the 3-phase PowerGuide ® 4400 is the only advanced power mon<strong>it</strong>oring instrument to incorporate a colortouch screen into <strong>it</strong>s lightweight design. Automated setups provide instant detection of circu<strong>it</strong>s and configurations, ensuring that the instrumentis ready to successfully collect data. Users can select the length and mode of data collection, including troubleshooting, data logging, powerqual<strong>it</strong>y surveys, energy and load balancing. The PowerGuide collects data at 256 samples/cycle/channel, offers remote communications usingRS-232, ethernet or USB options, and meets IEEE 1159, IEC 61000-4-30 and EN50160 standards.POWERGUIDE 4400DataTroubleshootingThe PowerGuide 4400’s unique annunciator “report card” provides instantpower qual<strong>it</strong>y answers in the field. A wide range of power mon<strong>it</strong>oring datais collected, analyzed and tabulated in color-coded categories to quicklyidentify areas of concern, whichare identified in red. Drill downfor more detailed information bysimply touching the intu<strong>it</strong>ivegraphical screen to troubleshootproblems, locate the source andpinpoint the root cause of powerqual<strong>it</strong>y disturbances.Fault RecordingThe PowerGuide 4400’s simple fault recording mode provides instantaneousdetection of electrical malfunctions and identification of faults w<strong>it</strong>hin afacil<strong>it</strong>y’s power infrastructure. The PowerGuide will characterize themagn<strong>it</strong>ude and duration of afault and help direct the usertoward <strong>it</strong>s source. Informationincluding voltage and currentfrequency stabil<strong>it</strong>y, power flowand harmonics underlie thePowerGuide’s diagnosticcapabil<strong>it</strong>ies.can be viewed in real time usingscope mode, meter mode, eventmode, harmonics spectrum or phasordiagrams. W<strong>it</strong>h the touch of yourfinger or a stylus, you can view dataand zoom-in on captured disturbancesfor more detail and automated eventcharacterization. All measuringmodes are self-contained in theinstrument, eliminating the need forTaskCards. Capture data on amemory card for analysis, trending,visualization and reporting usingindustry-leading DRAN-VIEW ® software.DRAN-VIEW makes <strong>it</strong> simple to trendevents, correlate data, analyze worstcasescenarios, simultaneously viewdata from multiple s<strong>it</strong>es, generatecustom reports, and understandcomplex issues such as transients,harmonics and interharmonics.Visualization and reporting options using DRAN-VIEWPhasorScopeSetupInrushThe startup of motors, transformer energization, breaker trips, and theactivation of backup generators and other applications w<strong>it</strong>h inrush cond<strong>it</strong>ionsrequire extended cycle-by-cycle recording to ensure proper operation andto determine their impact onother devices. The PowerGuide4400 goes beyond other powermon<strong>it</strong>oring instruments byproviding current-based RMStriggers and peak thresholdcrossings to optimize theperformance and longev<strong>it</strong>y ofthat essential equipment.Compliance Mon<strong>it</strong>oringThe PowerGuide 4400 has been designed to meet the most advanced powerqual<strong>it</strong>y standards, including IEEE 1159, IEC 61000-4-30 Class A andEN50160. A statistical output is produced to quickly verify compliance w<strong>it</strong>hinternational qual<strong>it</strong>y-of-supplystandards and benchmarkpower qual<strong>it</strong>y. In an instant, thePowerGuide provides a snapshotof over 13 key parameters,including unbalance, voltagevariations and harmonics.Energy SurveysThe cost of energy is oftentimes a facil<strong>it</strong>y’s largest operating expense.Reducing energy consumption during peak times, shifting loads, purchasingenergy efficient equipment, or changing energy suppliers can shave 10-40%annually off that cost. ThePowerGuide 4400 is an invaluabletool for performing energysurveys, including mon<strong>it</strong>oringenergy consumption, usagepatterns, peak demands and theactivation of large loads toreduce electric<strong>it</strong>y costs. Plus,the PowerGuide makes <strong>it</strong> easy totrack and allocate energy costsby process or department.Equipment Performance TestingDetermining the availabil<strong>it</strong>y and compatibil<strong>it</strong>y of facil<strong>it</strong>y power prior to theinstallation of new equipment is simplified using the PowerGuide 4400.The instrument incorporates advanced features such as RMS triggers,low/medium frequency transients,and cross triggeringbetween channels to demonstratethat power m<strong>it</strong>igation devicessuch as UPSs are operatingproperly. Real time readingsobserved during maintenanceand startup processes enableusers to see results and tweakthat equipment during thetesting process.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!