POWERGUIDE4400SPECIFICATIONSMeasured Parameters(4) differential inputs, 1-600 Vrms, AC/DC, 0.1% rdg,256 samples/cycle, 16 b<strong>it</strong> ADC(4) inputs w<strong>it</strong>h CTs 1-6000 Arms, CT-dependent, AC/DC,256 samples/cycle, 0.1% rdg + CTs, 16 b<strong>it</strong> ADCFrequency range, 10 mHz resolution, 45-65 HzPhase Lock Loop - Standard PQ modeMon<strong>it</strong>oring/ComplianceIEEE 1159IEC 61000-4-30 Class AEN50160 Qual<strong>it</strong>y of SupplyCurrent Inrush/ EnergizationVoltage Fault RecordingLong Term Mon<strong>it</strong>oring w/min/max/avgContinuous Data LoggingPower Qual<strong>it</strong>y TriggersCycle-by-cycle analysis256 samples/cycle; 1/2 cycle RMS stepsL-L, L-N, N-G RMS Variations: Sags/swells/interruptionsRMS Recordings V & I (32 pre-fault, 10K post-fault cycles)Waveshape Recordings (32 pre-fault, 10K post-fault cycles)Low and Medium Frequency Transients - V & IHarmonics Summary ParametersCross trigger V & I channelsRMS Event Characterization (IEEE or IEC)Distortion/Power/EnergyW, VA, VAR, TPF, DPF, Demand, Energy, etc.Harmonics / Interharmonics per IEC 61000-4-7THD/Harmonic Spectrum (V,I,W) to 63rdTID/Interharm. Spectrum (V,I) to 63rdFlicker per IEC 61000-4-15 (Pst,Plt,Sliding Plt)Crest Factor, K Factor, Transformer Derating Factor,Telephone Interference FactorAvailable LanguagesEnglish, French, Italian, German, Spanish, SwedishGeneral SpecificationsSize (HxWxD): 12" x 2.5" x 8" (30cm x 6.4cm x 20.3cm)Weight: 3.8 pounds (1.8 kg)Operating Temperature: 0º to 50º C (32º to 122º F)Storage Temperature: -20º to 55º C (4º to 131º F)Humid<strong>it</strong>y: 10 to 90% non-condensingSystem Time Clock: Crystal controlled, 1 second resolutionCharger /Battery Eliminator: 90-264 VAC 47-63 HzDisplay: LCD color touch screenMemory options (must have one): 32M-128M removablecompact flashcardOptional AccessoriesCurrent Probes: An extensive selection, including:Model TR-2510A 0-10 A; up to 0.47" conductorsModel TR-2500A 10-500 A; up to 1/8" diameteror 2.5"x 0.2"conductorsModel TR-2520A 300-3000 A; up to 2.56" diameter or1.97" x 5.3" (bus bar)Model TR-2019B 1-300 A; up to 2.0" conductors(requires 116002-G1 adapter)Flexible probes: ranging in current from 30-6000 A,24", 36", 48"Hall Effect Probes for AC/DC applications, 150 A or 1500 ACT Cable Adapter (CA4300LEM)Voltage Cable Accessory Pack (VCP4300)Soft Carrying Case (SCC-4300)Field Replaceable Battery Pack (BP-PX5)External Battery Charger (XBC-PX5)Reusable Shipping Container (RSC-4300)Weatherproof Container (NEMA4300)Lockable Portable Case (LPC-4300)Portable Field Printer (PFP4300)Communications Interface:RS232 FiberOptic Adapter (COMM-RS232)USB FiberOptic Adapter (COMM-OUA)LAN-FiberOptic Adapter (COMM-OEA)DRAN-VIEW software: Runs under Windows 98, ME, NTand XPNodeLink ® w<strong>it</strong>h <strong>download</strong>, setups and meterCD-ROM Training ProgramPOWERGUIDE4400Power Qual<strong>it</strong>y Analyzerdranetz-bmi.com1.800.372.6832 sales@dranetz-bmi.comtel 732.287.3680 • fax 732.248.1834 • 1000 New Durham Road • Edison, New Jersey 08818 USAPowerGuide, NodeLink and DRAN-VIEW are trademarks of <strong>Dranetz</strong>-BMI. ©2003 <strong>Dranetz</strong>-BMI. All rights reserved.Printed in the Un<strong>it</strong>ed States. Specifications are subject to change w<strong>it</strong>hout notice.www.dranetz-bmi.com“Out of the Box and Ready To Go,”3-phase, 8-channelPower Mon<strong>it</strong>oring Instrument
Equipped w<strong>it</strong>h 8 independent channels, the 3-phase PowerGuide ® 4400 is the only advanced power mon<strong>it</strong>oring instrument to incorporate a colortouch screen into <strong>it</strong>s lightweight design. Automated setups provide instant detection of circu<strong>it</strong>s and configurations, ensuring that the instrumentis ready to successfully collect data. Users can select the length and mode of data collection, including troubleshooting, data logging, powerqual<strong>it</strong>y surveys, energy and load balancing. The PowerGuide collects data at 256 samples/cycle/channel, offers remote communications usingRS-232, ethernet or USB options, and meets IEEE 1159, IEC 61000-4-30 and EN50160 standards.POWERGUIDE 4400DataTroubleshootingThe PowerGuide 4400’s unique annunciator “report card” provides instantpower qual<strong>it</strong>y answers in the field. A wide range of power mon<strong>it</strong>oring datais collected, analyzed and tabulated in color-coded categories to quicklyidentify areas of concern, whichare identified in red. Drill downfor more detailed information bysimply touching the intu<strong>it</strong>ivegraphical screen to troubleshootproblems, locate the source andpinpoint the root cause of powerqual<strong>it</strong>y disturbances.Fault RecordingThe PowerGuide 4400’s simple fault recording mode provides instantaneousdetection of electrical malfunctions and identification of faults w<strong>it</strong>hin afacil<strong>it</strong>y’s power infrastructure. The PowerGuide will characterize themagn<strong>it</strong>ude and duration of afault and help direct the usertoward <strong>it</strong>s source. Informationincluding voltage and currentfrequency stabil<strong>it</strong>y, power flowand harmonics underlie thePowerGuide’s diagnosticcapabil<strong>it</strong>ies.can be viewed in real time usingscope mode, meter mode, eventmode, harmonics spectrum or phasordiagrams. W<strong>it</strong>h the touch of yourfinger or a stylus, you can view dataand zoom-in on captured disturbancesfor more detail and automated eventcharacterization. All measuringmodes are self-contained in theinstrument, eliminating the need forTaskCards. Capture data on amemory card for analysis, trending,visualization and reporting usingindustry-leading DRAN-VIEW ® software.DRAN-VIEW makes <strong>it</strong> simple to trendevents, correlate data, analyze worstcasescenarios, simultaneously viewdata from multiple s<strong>it</strong>es, generatecustom reports, and understandcomplex issues such as transients,harmonics and interharmonics.Visualization and reporting options using DRAN-VIEWPhasorScopeSetupInrushThe startup of motors, transformer energization, breaker trips, and theactivation of backup generators and other applications w<strong>it</strong>h inrush cond<strong>it</strong>ionsrequire extended cycle-by-cycle recording to ensure proper operation andto determine their impact onother devices. The PowerGuide4400 goes beyond other powermon<strong>it</strong>oring instruments byproviding current-based RMStriggers and peak thresholdcrossings to optimize theperformance and longev<strong>it</strong>y ofthat essential equipment.Compliance Mon<strong>it</strong>oringThe PowerGuide 4400 has been designed to meet the most advanced powerqual<strong>it</strong>y standards, including IEEE 1159, IEC 61000-4-30 Class A andEN50160. A statistical output is produced to quickly verify compliance w<strong>it</strong>hinternational qual<strong>it</strong>y-of-supplystandards and benchmarkpower qual<strong>it</strong>y. In an instant, thePowerGuide provides a snapshotof over 13 key parameters,including unbalance, voltagevariations and harmonics.Energy SurveysThe cost of energy is oftentimes a facil<strong>it</strong>y’s largest operating expense.Reducing energy consumption during peak times, shifting loads, purchasingenergy efficient equipment, or changing energy suppliers can shave 10-40%annually off that cost. ThePowerGuide 4400 is an invaluabletool for performing energysurveys, including mon<strong>it</strong>oringenergy consumption, usagepatterns, peak demands and theactivation of large loads toreduce electric<strong>it</strong>y costs. Plus,the PowerGuide makes <strong>it</strong> easy totrack and allocate energy costsby process or department.Equipment Performance TestingDetermining the availabil<strong>it</strong>y and compatibil<strong>it</strong>y of facil<strong>it</strong>y power prior to theinstallation of new equipment is simplified using the PowerGuide 4400.The instrument incorporates advanced features such as RMS triggers,low/medium frequency transients,and cross triggeringbetween channels to demonstratethat power m<strong>it</strong>igation devicessuch as UPSs are operatingproperly. Real time readingsobserved during maintenanceand startup processes enableusers to see results and tweakthat equipment during thetesting process.