21.08.2015 Views

CENTRAL INSTITUTE OF TECHNOLOGY ... - CIT, Kokrajhar...

CENTRAL INSTITUTE OF TECHNOLOGY ... - CIT, Kokrajhar...

CENTRAL INSTITUTE OF TECHNOLOGY ... - CIT, Kokrajhar...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SECTION-5: SCHEDULE <strong>OF</strong> REQUIREMENTS,SPECIFICATIONS & ALLIED TECHNICAL DETAILS1. Vendors should visit the actual site i.e. the Guest House for installation of Guest House and fittings tomeasure every room in each floor of the Guest House for quoting the dimensions (Length, Breadthand Height) of the Guest House items as shown in the layout of the Guest House in Figure-1 andFigure-2.2. All modular Guest House shall be customized to meet the design and dimension requirements oflocations specified in the Guest House. The modular Guest House shall be made of particle board/ plyboard preferably of exterior grade or conforming to IS3087 and pre laminated particle boardconforming to IS 12823 of approved shade. The shape of the entire unit will be for the optimumutilization of the available space as shown in the layout diagram provided with the Figure-1 andFigure-2.3. All hardware shall be Hettich/Haffle or equivalent makes. The exact design of the unit will beprovided by the Institute; hence you are requested to submit item designs also.4. All table structure should have the facility of electrical connection, such as electrical race way forcabling, junctions with switch and sockets in modular form etc.5. The workstations should have key board tray of PVC or metal along with metal CPU trolley forconvenience of use. The entire work should considered as turnkey basis including all the above in allrespect.6. Screws shall match the finish of the article to be fixed and to be round or flat headed or counter sunkas required.7. Aluminum CRC Steel and stainless steel shall be of BIS grade and suitable for its particularapplication. The surface of all M.S/CRCA Components shall undergo 7stages pre–treatment as perISO standard.8. Double Bed for VIP Suite:Modular Double bed of appropriate master bed size. Bed Structure will consist of 25mm thickexterior grade MDF finishing with both side high pressure 1.5mm or 1mm thick laminate by hot pressmachine at 180* C . All visible panels including Head board, Foot board shall be 36mm thick exteriorgrade MDF finishing with 1.5mm or 1mm thick both side high pressure laminate. Must ensure designor post formed add on which is made by CNC machine to be fixed with proper hardware on HeadBoard and Foot Board. Bed sides panels are made of 25mm Thick exterior grade MDF finishing withhigh pressure laminate All the exposed edges are edge banded with 2.0mm thick PVC edge bandingby machine at 180*c with hot melt glue. The bed should rest on four heavy duty SS legs with rubbergaskets of height 62mm or PVC buffer for efficient cleaning. All hardware to be Hettich/Hafele or23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!