Veritas Storage Foundation and High Availability Solutions Release Notes
Veritas Storage Foundation⢠and High ... - SORT - Symantec Veritas Storage Foundation⢠and High ... - SORT - Symantec
166Upgrading to 6.0.3Upgrading to 6.0.33 Check the readiness of the nodes where you plan to upgrade. From thedirectory that contains the extracted and untarred 6.0.3 rolling patch binaries,change to the directory that contains the installmr script. Start thepre-upgrade check:# ./installmr -precheck node1 node2 ... nodeNSee “About the installmr and the uninstallmr scripts” on page 12.4 Resolve any issues that the precheck finds.5 Start the upgrade:# ./installmr node1 node2 ... nodeNSee “About the installmr and the uninstallmr scripts” on page 12.6 After the upgrade, review the log files for any issues.Performing a full upgrade to 6.0.3 on an SFHA clusterThe following procedure describes performing a full upgrade on an SFHA andVCS cluster.To perform a full upgrade to 6.0.3 on an SFHA cluster1 Make sure you have downloaded the latest software required for the upgrade.See “Downloading required software to upgrade to 6.0.3 ” on page 163.2 Log in as superuser.3 Verify that /opt/VRTS/bin and /opt/VRTSvcs/bin is in your PATH so thatyou can execute all product commands.4 If you install VCS on Solaris 10 systems that run non-global zones, make surethat all non-global zones are booted and in the running state on each nodebefore you upgrade the SFHA stack in the global zone.5 On any node in the cluster, make the VCS configuration read only:# haconf -dump -makero6 Stop VCS.To stop applications, unmount VxFS file systems and stop VxVM volumesmanaged by VCS.# hastop -all
Upgrading to 6.0.3Upgrading to 6.0.31677 Stop all the applications that are using VxFS files systems and VxVM volumeswhich are not managed by VCS.Use application’s native commands to stop applications.8 On each node, enter the following command to check if any StorageCheckpoints are mounted:# df -F vxfsIf any Storage Checkpoints are mounted, on each node in the cluster, unmountall Storage Checkpoints.# umount /checkpoint_name9 On each node, enter the following command to check if any VxFS file systemsare mounted.Unmount the VxFS file systems that are not managed by VCS.# df -F vxfsIf any VxFS file systems are present, on each node in the cluster, stop IOs onthe file systems, unmount all of the VxFS file systems:# umount /filesystem10 If you have created any Veritas Volume Replicator (VVR) replicated volumegroups (RVGs) on your system, perform the following steps:■■Stop all applications that are involved in replication. For example, if adata volume contains a file system, unmount it.Use the vxrvg stop command to stop each RVG individually:# vxrvg -g diskgroup stop rvg_name■On the Primary node, use the vxrlink status command to verify that allRLINKs are up-to-date:# vxrlink -g diskgroup status rlink_nameCaution: To avoid data corruption, do not proceed until all RLINKs areup-to-date.
- Page 115 and 116: About Veritas Storage Foundation an
- Page 117 and 118: About Veritas Storage Foundation an
- Page 119 and 120: About Veritas Storage Foundation an
- Page 121 and 122: About Veritas Storage Foundation an
- Page 123 and 124: About Veritas Storage Foundation an
- Page 125 and 126: About Veritas Storage Foundation an
- Page 127 and 128: About Veritas Storage Foundation an
- Page 129 and 130: About Veritas Storage Foundation an
- Page 131 and 132: About Veritas Storage Foundation an
- Page 133 and 134: About Veritas Storage Foundation an
- Page 135 and 136: About Veritas Storage Foundation an
- Page 137 and 138: About Veritas Storage Foundation an
- Page 139 and 140: About Veritas Storage Foundation an
- Page 141 and 142: About Veritas Storage Foundation an
- Page 143 and 144: About Veritas Storage Foundation an
- Page 145 and 146: About Veritas Storage Foundation an
- Page 147 and 148: About Veritas Storage Foundation an
- Page 149 and 150: Chapter2Installing the products for
- Page 151 and 152: Installing the products for the fir
- Page 153 and 154: Installing the products for the fir
- Page 155 and 156: Chapter3Installing the productsusin
- Page 157 and 158: Installing the products using JumpS
- Page 159 and 160: Installing the products using JumpS
- Page 161 and 162: Installing the products using JumpS
- Page 163 and 164: Chapter4Upgrading to 6.0.3This chap
- Page 165: Upgrading to 6.0.3Upgrading to 6.0.
- Page 169 and 170: Upgrading to 6.0.3Upgrading to 6.0.
- Page 171 and 172: Upgrading to 6.0.3Upgrading to 6.0.
- Page 173 and 174: Upgrading to 6.0.3Upgrading to 6.0.
- Page 175 and 176: Upgrading to 6.0.3Upgrading to 6.0.
- Page 177 and 178: Upgrading to 6.0.3Upgrading to 6.0.
- Page 179 and 180: Upgrading to 6.0.3Upgrading to 6.0.
- Page 181 and 182: Upgrading to 6.0.3Upgrading to 6.0.
- Page 183 and 184: Upgrading to 6.0.3Upgrading to 6.0.
- Page 185 and 186: Upgrading to 6.0.3Upgrading to 6.0.
- Page 187 and 188: Upgrading to 6.0.3Upgrading to 6.0.
- Page 189 and 190: Upgrading to 6.0.3Upgrading to 6.0.
- Page 191 and 192: Upgrading to 6.0.3Upgrading to 6.0.
- Page 193 and 194: Upgrading to 6.0.3Verifying softwar
- Page 195 and 196: Chapter5Uninstalling version 6.0.3T
- Page 197 and 198: Uninstalling version 6.0.3Rolling b
- Page 199 and 200: Uninstalling version 6.0.3Rolling b
- Page 201 and 202: Uninstalling version 6.0.3Rolling b
- Page 203 and 204: Uninstalling version 6.0.3Rolling b
- Page 205 and 206: Uninstalling version 6.0.3Rolling b
- Page 207 and 208: Uninstalling version 6.0.3Rolling b
- Page 209 and 210: Uninstalling version 6.0.3Rolling b
- Page 211 and 212: Uninstalling version 6.0.3Rolling b
- Page 213 and 214: Uninstalling version 6.0.3Rolling b
- Page 215 and 216: Uninstalling version 6.0.3Rolling b
166Upgrading to 6.0.3Upgrading to 6.0.33 Check the readiness of the nodes where you plan to upgrade. From thedirectory that contains the extracted <strong>and</strong> untarred 6.0.3 rolling patch binaries,change to the directory that contains the installmr script. Start thepre-upgrade check:# ./installmr -precheck node1 node2 ... nodeNSee “About the installmr <strong>and</strong> the uninstallmr scripts” on page 12.4 Resolve any issues that the precheck finds.5 Start the upgrade:# ./installmr node1 node2 ... nodeNSee “About the installmr <strong>and</strong> the uninstallmr scripts” on page 12.6 After the upgrade, review the log files for any issues.Performing a full upgrade to 6.0.3 on an SFHA clusterThe following procedure describes performing a full upgrade on an SFHA <strong>and</strong>VCS cluster.To perform a full upgrade to 6.0.3 on an SFHA cluster1 Make sure you have downloaded the latest software required for the upgrade.See “Downloading required software to upgrade to 6.0.3 ” on page 163.2 Log in as superuser.3 Verify that /opt/VRTS/bin <strong>and</strong> /opt/VRTSvcs/bin is in your PATH so thatyou can execute all product comm<strong>and</strong>s.4 If you install VCS on Solaris 10 systems that run non-global zones, make surethat all non-global zones are booted <strong>and</strong> in the running state on each nodebefore you upgrade the SFHA stack in the global zone.5 On any node in the cluster, make the VCS configuration read only:# haconf -dump -makero6 Stop VCS.To stop applications, unmount VxFS file systems <strong>and</strong> stop VxVM volumesmanaged by VCS.# hastop -all