17.08.2015 Views

Veritas Storage Foundation and High Availability Solutions Release Notes

Veritas Storage Foundation™ and High ... - SORT - Symantec

Veritas Storage Foundation™ and High ... - SORT - Symantec

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

About <strong>Veritas</strong> <strong>Storage</strong> <strong>Foundation</strong> <strong>and</strong> <strong>High</strong> <strong>Availability</strong> <strong>Solutions</strong>Known issues125Resolution: During the transition time interval between online <strong>and</strong> offline, do notissue a probe for the Sybase resource, otherwise the node may reboot.Unexpected node reboot when invalid attribute is given (2567507)Problem: A node may reboot unexpectedly if the Home, Version, or Serverattributes are modified to invalid values while the Sybase resources are online inVCS.Resolution: Avoid setting invalid values for the Home, Version, or Server attributeswhile the Sybase resources are online in VCS, to avoid panic of the node.AutoFailOver = 0 attribute absent in the sample files at/etc/VRTSagents/ha/conf/Sybase (2615341)Problem: AutoFailOver = 0 attribute is not present in the sample files at/etc/VRTSagents/ha/conf/Sybase.Resolution: If you copy the main.cf file from the /etc/VRTSagents/ha/conf/Sybaselocation, add the AutoFailOver = 0 attribute to the binmnt <strong>and</strong> sybasece servicegroups.Symantec VirtualStore known issuesThis section describes the Symantec VirtualStore known issues in 6.0.3.Symantec VirtualStore issuesThe svsiscsiadm create lun comm<strong>and</strong> fails if you create a LUN greater thanthe available space on the file system (2567517)The svsiscsiadm create lun comm<strong>and</strong> fails if you create a LUN of a size greaterthan the total amount of space available on the file system. The underlyingiscsitadm comm<strong>and</strong> fails with the following error message:iscsitadm: Error Requested size is too large for systemThe report of this error is logged in the /var/VRTSvcs/log/engine_A.log file.If you then try to create a LUN on the same target, the LUN creation call failsagain with the following error message:iscsitadm: Error Failed to create a symbolic link to the backing storeThe report of this error is logged in the /var/VRTSvcs/log/engine_A.log file.This makes the target unusable.Workaround

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!