FileShare agents<br />

CompositeFileShare agent<br />

91<br />

Table 4-4<br />

CompositeFileShare agent optional attributes (continued)<br />

Optional Attributes<br />

ShareComment<br />

Description<br />

A string that describes the share. Use this attribute to add<br />

comments to the compositefileshare resource.<br />

If this attribute is blank, the agent uses the default VCS<br />

comment.<br />

Type and Dimension: string-scalar<br />

Sample configuration<br />

CompositeCFS CFS-RES (<br />

Critical = 1<br />

LanmanResName = CFS_SG-Lanman<br />

MountResName = CFS_SG-MountV<br />

UserPermissions = { Everyone = READ_ONLY }<br />

ShareSubdirectories = 1<br />

PathAndShareName = { "\\share2" = share2,<br />

"\\share3" = share3 }<br />

AccessBasedEnumeration = 1<br />

)<br />

IP CFS_SG-IP (<br />

Address = "10.212.100.184"<br />

SubNetMask = "255.255.254.0"<br />

MACAddress @SYSTEM1 = "00-02-B3-AD-CE-E4"<br />

MACAddress @SYSTEM2 = "00-02-B3-AD-CB-D0"<br />

)<br />

Lanman CFS_SG-Lanman (<br />

VirtualName = VNAME<br />

IPResName = CFS_SG-IP<br />

)<br />

MountV CFS_SG-MountV (<br />

MountPath = "J:"<br />

VolumeName = PS-SPOOL<br />

VMDGResName = CFS_SG-VMDg<br />

)<br />

NIC CFS_SG-NIC (<br />

MACAddress @SYSTEM1 = "00-02-B3-AD-CE-E4"