54<br />

Network agents<br />

NIC agent<br />

Table 3-2<br />

NIC agent optional attributes (continued)<br />

Optional Attributes<br />

PingHostList<br />

Description<br />

A list of hosts that are always reachable from the NIC. If the<br />

UseConnectionStatus attribute is set to 0, make sure the<br />

attribute PingHostList is not empty.<br />

Type and Dimension: string-vector<br />

PingTimeoutMseconds<br />

The timeout interval, in milliseconds, for a ping. Default is<br />

1000 milliseconds.<br />

Type and Dimension: integer-scalar<br />

UseConnectionStatus<br />

Defines whether the NIC maintains its connection status.<br />

The value True indicates the NIC maintains its status. The<br />

value False indicates it does not. If this attribute is set to<br />

False, you must specify a value for the attribute<br />

PingHostList. Default is True.<br />

VCS provides a utility, "NICTest," which determines whether<br />

a NIC maintains its connection status. You can use the<br />

NICTest utility to determine whether or not this attribute<br />

is required. See the description of the NICTest utility in the<br />

<strong>Veritas</strong> <strong>Cluster</strong> <strong>Server</strong> Administrator's <strong>Guide</strong> for instructions.<br />

Type and Dimension: boolean-scalar<br />

Sample configuration<br />

In the following example, the NIC agent is configured to monitor the adapter with<br />

MAC address 00-B0-D0-31-7D-FA. The UseConnectionStatus attribute is set to<br />

False. The agent sends a ping to the hosts listed in the PingHostList attribute to<br />

determine the status of the NIC resource. If the percentage of erroneous packets<br />

transmitted exceeds 30 percent for three consecutive monitoring intervals, the<br />

NIC resource is marked FAULTED.<br />

NIC NIC_RL20001 (<br />

)<br />

MACAddress = "00-B0-D0-31-7D-FA"<br />

PingTimeOutMseconds = 500<br />

MaxTxErrorPercentage = 30<br />

MaxTxErrInterval = 3<br />

UseConnectionStatus = False<br />

PingHostList = { "172.16.1.19", "172.16.1.21" }