Storage agents<br />
MountV agent<br />
37<br />
str VolumeName<br />
str VMDGResName<br />
str ForceUnmount = READ_ONLY<br />
boolean ListApplications = 1<br />
boolean AutoFSClean = 1<br />
str MountResName<br />
boolean PurgeStaleMountPoints = 1<br />
boolean CheckFSAccess = 0<br />
boolean ForFireDrill = 0<br />
boolean BlockMountPointAccess = 0<br />
)<br />
Attribute definitions<br />
This section summarizes the required and optional attributes of the MountV<br />
agent.<br />
Table 2-7<br />
MountV agent required attributes<br />
Required Attributes<br />
MountPath<br />
Description<br />
The drive letter or path to an empty NTFS folder that will be assigned to the volume<br />
being mounted.<br />
When configuring a directory to host the mount, verify the following conditions:<br />
■<br />
■<br />
■<br />
■<br />
The configured path exists.<br />
The directory is empty.<br />
The volume on which the directory resides is NTFS-formatted.<br />
The directory is not a system directory.<br />
The attribute can be specified as X, X:, X:\, X:\Directory, or X:\Directory\.<br />
These options are valid only if editing the attribute from <strong>Cluster</strong> Manager (Java Console).<br />
If editing the configuration file main.cf directly, you must specify two slashes (\\)<br />
instead of one; for example, X:\\Directory\\.<br />
Note: This attribute can take localized values.<br />
Type and Dimension: string-scalar<br />
VolumeName<br />
The name of the volume to be mounted. For example, the name could be Raid1, Stripe2,<br />
Volume01, etc. Use the VMGetDrive utility to retrieve the volume name. See the<br />
description of the VMGetDrive utility in the <strong>Veritas</strong> <strong>Cluster</strong> <strong>Server</strong> Administrator's<br />
<strong>Guide</strong> for instructions.<br />
Type and Dimension: string-scalar