Selected Applications Including - ELIN Motoren GmbH
Selected Applications Including - ELIN Motoren GmbH
Selected Applications Including - ELIN Motoren GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
We keep the world in motion.<br />
Compressor Drives (Oil & Gas)<br />
<strong>Selected</strong> applications including the field of Oil & Gas<br />
November 2009
Air/Water Cooled Motors<br />
<strong>ELIN</strong> Type: HKM<br />
Cooling Method: IC81W (TEAWC)<br />
November 2009
Project:<br />
Location:<br />
Year:<br />
Page 3<br />
Friotherm / „Skoyen04“<br />
Norway<br />
2005<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-180 E04<br />
7,000 kW<br />
11,000 V<br />
Air/Water<br />
1<br />
Compressor Axima<br />
Uniturbo 50<br />
Highest efficiency<br />
η=97.55 %<br />
Low noise emission<br />
Reduced vibration level<br />
- Shaft vibration<br />
measurement<br />
- Bearing housing<br />
measurement<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 4<br />
Friotherm / „Turku“<br />
Skandinavia<br />
2007<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-171 E04<br />
6,500 kW<br />
10,000 V<br />
Air/Water<br />
1<br />
Friotherm Uniturbo<br />
High efficiency<br />
97.6 %<br />
Low starting current<br />
Ia/In = 4.8<br />
Pressure of cooling<br />
water 16 bar<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 5<br />
Siemens AG / „Bayer Uerdingen“<br />
Krefeld, Deutschland<br />
2008<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-171E04<br />
5,550 kW<br />
10 kV (5 kV)<br />
Air/Water<br />
1<br />
Turbo compressor<br />
STC-GC<br />
Adjustable input<br />
voltage range<br />
10 kV or 5 kV<br />
In special designed<br />
main terminal box<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 6<br />
Air Products (USA) / „Reidsville Liquifier“<br />
Reidsville North Carolina, USA<br />
2008<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-156 D04<br />
3,500 kW<br />
4,000 V<br />
Water<br />
1<br />
Compressor Cameron<br />
TAE2000<br />
Second shaft end for<br />
oil pump IM1002<br />
Customer specific<br />
cable connection<br />
Highest efficiency<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 7<br />
Air Products (UK) / „Dragon“<br />
Milford Haven, United Kingdom<br />
2007<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-171 E02<br />
4,500 kW<br />
11,000 V<br />
Air/Water<br />
3<br />
LNG Compressor<br />
TA-20000M5R3/30<br />
Low starting current<br />
5.6xFLC at 100 % Vr<br />
max. 3 % voltage drop<br />
via Autotransformer<br />
Special main terminal<br />
box with:<br />
- Diff. Protec. CT<br />
- Measuring CT<br />
- Surge Capacitors<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 8<br />
Air Products (USA) / „Reidsville Recycle“<br />
Reidsville North Carolina, USA<br />
2008<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-171 E04<br />
6,600 kW<br />
4,000 V<br />
Air/Water<br />
2<br />
Turbo compressor<br />
Cameron MSG11<br />
Highest efficiency<br />
Second shaft end for<br />
oil pump<br />
Customer specific<br />
cable connection<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 9<br />
O2 Werk LINDE Gas / „VOEST Alpine“<br />
Linz, Austria<br />
1997 & 2000<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-163 E04<br />
4,600 kW<br />
6,000 V<br />
Air/Water<br />
2<br />
Compressor VK32-6<br />
Low starting current<br />
5xFLC<br />
Highest efficiency<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 10<br />
LINDE / „Hassi Messaoud“<br />
Algeria<br />
2001<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-156 D02<br />
2,500 kW<br />
6,000 V<br />
Air/Water<br />
1<br />
Turbo compressor<br />
IP65<br />
Operation in desert<br />
60° C water<br />
temperature<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 11<br />
Siemens / „Infraleuna“<br />
Germany<br />
1997<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-156 D02<br />
1,850 kW<br />
6,000 V<br />
Air/Water<br />
3<br />
Turbo compressor<br />
CVK16-3<br />
Low starting current<br />
Highest efficiency<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 12<br />
MAN / „Dillingen“<br />
Germany<br />
2004<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-110 D04<br />
13,000 kW<br />
6,000 V<br />
Air/Water<br />
1<br />
Turbo compressor<br />
Low starting current<br />
4.3 times FLC at rated<br />
voltage (Vr)<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 13<br />
AIR PRODUCTS / „Steel Mill Gent“<br />
Belgium<br />
2004<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-110 D04<br />
13,600 kW<br />
6,000 V<br />
Air/Water<br />
1<br />
Air separation<br />
Low starting current<br />
3.8xFLC at 100 % Vr<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 14<br />
Solvay / „Banksmeadow“<br />
Australia<br />
1996<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-156 D02<br />
1,550 kW<br />
10,500 V<br />
Air/Water<br />
1<br />
Turbo compressor<br />
Low starting current<br />
(3.9-times at 100 Vr)<br />
Highest efficiency<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 15<br />
VAI / „Feinsint“<br />
Austria<br />
1993<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-156 D02<br />
1,900 kW<br />
6,000 V<br />
Air/Water<br />
2 p<br />
Process air compressor<br />
2-pole motor with lowest<br />
noise level 76 dB<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 16<br />
Axima / „Katri Vala“<br />
Finland<br />
2005<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-171 E04<br />
6,500 kW<br />
10,000 V<br />
Air/Water<br />
5<br />
Turbo compressor<br />
Low noise emission<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 17<br />
Voith / „Condea Augusta“<br />
Sicilia, Italy<br />
2000<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-171 D04<br />
5,500 kW<br />
6,000 V<br />
Water<br />
1piece<br />
Compressor<br />
EEx p T3<br />
Low starting current<br />
(4.4-times at 100 % of<br />
the nominal voltage)<br />
We keep the world in motion.
Air/Water Cooled Motors<br />
<strong>ELIN</strong> Type: HRM (Slip ring motors)<br />
Cooling Method: IC81W (TEAWC)<br />
November 2009
Project:<br />
Location:<br />
Year:<br />
Page 19<br />
PGW Turbo / „POSCO“<br />
Korea<br />
2006<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HRM-090D04<br />
10,000 kW<br />
6,600 V<br />
Air/Water<br />
3<br />
Turbo compressor<br />
Slip ring motor with fluid<br />
starter<br />
Auxiliaries in Ex Type<br />
Automatic short cut<br />
device<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 20<br />
AirLiquide / „Donawitz“<br />
Austria<br />
2006<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HRM-080 Z04<br />
5,500 kW<br />
6,000 V<br />
Air/Water<br />
1<br />
Turbo compressor<br />
Slip ring motor with fluid<br />
starter<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 21<br />
Biochemie Kundl / „Compressor 9“<br />
Austria<br />
1998<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HRM-056 D04<br />
2,250 kW<br />
6,000 V<br />
Air/Water<br />
1 piece<br />
Turbo compressor<br />
Maximum efficiency<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 22<br />
Jungbunzlauer / „Colborne“<br />
Canada<br />
2001<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HRM-063 C04<br />
2,000 kW<br />
13,800 V<br />
Air/Water<br />
3<br />
Turbo compressor<br />
CVK40-2<br />
CSA-design<br />
13.8 kV Slip ring<br />
motor<br />
We keep the world in motion.
Water Jacked Cooled Motors<br />
<strong>ELIN</strong> Type: HCZ (water jacked cooled)<br />
Cooling Method: IC7A0W7 (TEWC)<br />
November 2009
Project:<br />
Location:<br />
Year:<br />
Page 24<br />
„Purification Plant Hetlingen“<br />
Switzerland<br />
2000<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
MCZ-540 E02<br />
630 kW<br />
690 V<br />
water jacked cooled<br />
4<br />
Turbo compressor<br />
Highest efficiency<br />
Low noise emission<br />
Lowest friction losses<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 25<br />
AXIMA / „Refrigeration AG“<br />
Climespace Tokyo<br />
2005<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HCZ-545 L02<br />
1,250 kW<br />
5,500 V<br />
water jacket cooled<br />
8<br />
Turbo compressor<br />
Smoothness of running<br />
Grade B<br />
Balancing quality G1.6<br />
Low noise emission 77<br />
dB<br />
We keep the world in motion.
Air/Air Cooled Motors<br />
<strong>ELIN</strong> Type: HKL<br />
Cooling Methode: IC611 (TEAAC)<br />
November 2009
Project:<br />
Location:<br />
Year:<br />
Page 27<br />
VAI / „Russland“<br />
Russia<br />
2004<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKL-115 D04<br />
2,000 kW<br />
6,000 V<br />
Air cooled<br />
4<br />
Blower for steel plant<br />
High load moment of<br />
inertia J= 1300 kg/m²<br />
Environment<br />
temperature<br />
from -30 up to 40 °C<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 28<br />
Burckhardt Compressions / „Isle of Grain“<br />
Isle of Grain, Great Britain<br />
2006<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKL-171 D16<br />
1,300 kW<br />
6,600 V<br />
Air cooled (IC611)<br />
2<br />
BCA reciprocating<br />
compressor<br />
EEx nA in accordance<br />
with ATEX<br />
Degree of protection<br />
IP56<br />
Low noise emission 80<br />
dB(A)<br />
We keep the world in motion.
Air/Air Cooled Motors<br />
<strong>ELIN</strong> Type: HKG<br />
Cooling Methode: IC411 (TEFC)<br />
November 2009
Project:<br />
Location:<br />
Year:<br />
Page 30<br />
Siemens /„Purification Plant Linz Asten“<br />
Austria<br />
2000<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKG-545 C04<br />
630 kW<br />
6,300 V<br />
Air<br />
2<br />
Turbo compressor<br />
KA22SV<br />
Compressor for<br />
biological clarification<br />
We keep the world in motion.
Air/Air Cooled Motors<br />
<strong>ELIN</strong> Type: HKR<br />
Cooling Method: IC511 (TEPV)<br />
November 2009
Project:<br />
Location:<br />
Year:<br />
Page 32<br />
MAN / „Rasfuel“<br />
Qatar<br />
2005<br />
Courtesy of MAN Turbo<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights<br />
HKR-110 Z02<br />
3,075 kW<br />
6,600 V<br />
Air<br />
3<br />
Turbo compressor<br />
EExp II A T3<br />
Low noise level at<br />
2-pole Motor 83 dB(A)<br />
Starting current<br />
4.4-times FLC<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 33<br />
Siemens / „Repsol Ensenada“<br />
Mexico<br />
2006<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKR-110 B04<br />
3,000 kW<br />
6,600 V<br />
Air<br />
1<br />
Siemens Compressor<br />
STC- GV 32-2<br />
Low noise emission<br />
EEx nA protection<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 34<br />
MAN Turbo / BP /„NEREWAS“<br />
Netherlands<br />
2007<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKR-110 B02<br />
3,300 kW<br />
10,000 V<br />
Air/Air (IC511)<br />
1<br />
MAN Screw<br />
compressor<br />
EExp IIC T3 Zone 2<br />
Low noise level max<br />
83 dB at load<br />
Special requirements<br />
for accessories and<br />
material<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 35<br />
MAN Turbo / „LAVRIFUEL“<br />
Greek<br />
2005<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKR-180 B02<br />
1,275 kW<br />
6,000 V<br />
Air/Air (IC511)<br />
1<br />
MAN Compressor<br />
EExn IIB T3 Zone 2<br />
Low noise level max<br />
82.5 dB at load<br />
EExd Main Terminal<br />
Box<br />
We keep the world in motion.
Explosion-Proof Motors<br />
Protection Methode: Exn, Exe, Exp<br />
November 2009
Project:<br />
Location:<br />
Year:<br />
Page 37<br />
Kobleco / „Borealis Schwechat PP5“<br />
Schwechat (Austria)<br />
2005<br />
Courtesy of ConPackSys<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-163 D02<br />
3,550 kW<br />
10,000 V<br />
Air/Water<br />
1<br />
Compressor Kobleco<br />
M-C-4401X<br />
Highest application<br />
efficiency<br />
Low starting current<br />
4.5xFLC<br />
Low noise emission<br />
80 dB + 3 dB Tolerance<br />
Ex-Protection:<br />
Ex II 2G Ex-pe IIB T3<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 38<br />
Atlas Copco / „Borealis PP“<br />
Schwechat, Austria<br />
2004<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-156 D02<br />
1,800 kW<br />
10,000 V<br />
Air/Water<br />
1<br />
Turbo compressor<br />
Pressurized design<br />
EExp in accordance<br />
with ATEX<br />
Low starting current<br />
4.5xFLC<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 39<br />
Siemens / „Repsol Ensenada“<br />
Mexico<br />
2006<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKR-110 B04<br />
3,000 kW<br />
6,600 V<br />
Air<br />
1<br />
Siemens Compressor<br />
STC- GV 32-2<br />
Low noise emission<br />
EEx nA protection<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 40<br />
MAN / „Rasfuel“<br />
Qatar<br />
2005<br />
Courtesy of MAN Turbo<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights<br />
HKR-110 Z02<br />
3,075 kW<br />
6,600 V<br />
Air<br />
3<br />
Turbo compressor<br />
EExp II A T3<br />
Low noise level at<br />
2-pole Motor 83 dB(A)<br />
Starting current<br />
4.4-times FLC<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 41<br />
Burckhardt / „Borealis PP“<br />
Schwechat, Austria<br />
2004<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-190 C16<br />
1,990 kW<br />
10,000 V<br />
Air/Water<br />
1<br />
Turbo compressor<br />
Pressurized design<br />
EEx p in accordance<br />
with ATEX<br />
Low starting current<br />
4.5xFLC<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 42<br />
Kobelco Japan / „Borealis PP“ / Neste Oil<br />
Schwechat, Austria<br />
2008<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKE-550 L02<br />
930 kW<br />
6,000 V<br />
Air (IC411)<br />
1<br />
Turbo compressor<br />
EExe IIB T3 Zone 1<br />
Highest efficiency<br />
η=97.67 %<br />
Run out max 12.5µm<br />
Shaft vibration max<br />
50µm<br />
Noise level at load<br />
max. 80 dB<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 43<br />
Converteam – RWE DEA / „VOELGAS“<br />
Kreepen, Germany<br />
2007<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKM-171 D04<br />
5,000 kW<br />
3,300 V (Inverter)<br />
Air/Water<br />
3<br />
MAN Turbo<br />
compressor<br />
EExp IIB/C T3 Zone 2<br />
Operation on inverter<br />
High level of<br />
accessories<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 44<br />
MAN Turbo / BP /„NEREWAS“<br />
Netherlands<br />
2007<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKR-B110 B02<br />
3,300 kW<br />
10,000 V<br />
Air/Air (IC511)<br />
1<br />
MAN Screw<br />
compressor<br />
EExp IIC T3 Zone 2<br />
Low noise level max<br />
83 dB at load<br />
Special requirements<br />
for accessories and<br />
material<br />
We keep the world in motion.
Project:<br />
Location:<br />
Year:<br />
Page 45<br />
MAN Turbo / „LAVRIFUEL“<br />
Greek<br />
2005<br />
• Type:<br />
• Power:<br />
• Voltage:<br />
• Cooling:<br />
• Quantity:<br />
• Application:<br />
• Highlights:<br />
HKR-180 B02<br />
1,275 kW<br />
6,000 V<br />
Air/Air (IC511)<br />
1<br />
MAN Compressor<br />
EExn IIB T3 Zone 2<br />
Low noise level max<br />
82.5 dB at load<br />
EExd Main Terminal<br />
Box<br />
We keep the world in motion.