We keep the world in motion.<br />

Compressor Drives (Oil & Gas)<br />

<strong>Selected</strong> applications including the field of Oil & Gas<br />

November 2009


Air/Water Cooled Motors<br />

<strong>ELIN</strong> Type: HKM<br />

Cooling Method: IC81W (TEAWC)<br />

November 2009


Project:<br />

Location:<br />

Year:<br />

Page 3<br />

Friotherm / „Skoyen04“<br />

Norway<br />

2005<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-180 E04<br />

7,000 kW<br />

11,000 V<br />

Air/Water<br />

1<br />

Compressor Axima<br />

Uniturbo 50<br />

Highest efficiency<br />

η=97.55 %<br />

Low noise emission<br />

Reduced vibration level<br />

- Shaft vibration<br />

measurement<br />

- Bearing housing<br />

measurement<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 4<br />

Friotherm / „Turku“<br />

Skandinavia<br />

2007<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-171 E04<br />

6,500 kW<br />

10,000 V<br />

Air/Water<br />

1<br />

Friotherm Uniturbo<br />

High efficiency<br />

97.6 %<br />

Low starting current<br />

Ia/In = 4.8<br />

Pressure of cooling<br />

water 16 bar<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 5<br />

Siemens AG / „Bayer Uerdingen“<br />

Krefeld, Deutschland<br />

2008<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-171E04<br />

5,550 kW<br />

10 kV (5 kV)<br />

Air/Water<br />

1<br />

Turbo compressor<br />

STC-GC<br />

Adjustable input<br />

voltage range<br />

10 kV or 5 kV<br />

In special designed<br />

main terminal box<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 6<br />

Air Products (USA) / „Reidsville Liquifier“<br />

Reidsville North Carolina, USA<br />

2008<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-156 D04<br />

3,500 kW<br />

4,000 V<br />

Water<br />

1<br />

Compressor Cameron<br />

TAE2000<br />

Second shaft end for<br />

oil pump IM1002<br />

Customer specific<br />

cable connection<br />

Highest efficiency<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 7<br />

Air Products (UK) / „Dragon“<br />

Milford Haven, United Kingdom<br />

2007<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-171 E02<br />

4,500 kW<br />

11,000 V<br />

Air/Water<br />

3<br />

LNG Compressor<br />

TA-20000M5R3/30<br />

Low starting current<br />

5.6xFLC at 100 % Vr<br />

max. 3 % voltage drop<br />

via Autotransformer<br />

Special main terminal<br />

box with:<br />

- Diff. Protec. CT<br />

- Measuring CT<br />

- Surge Capacitors<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 8<br />

Air Products (USA) / „Reidsville Recycle“<br />

Reidsville North Carolina, USA<br />

2008<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-171 E04<br />

6,600 kW<br />

4,000 V<br />

Air/Water<br />

2<br />

Turbo compressor<br />

Cameron MSG11<br />

Highest efficiency<br />

Second shaft end for<br />

oil pump<br />

Customer specific<br />

cable connection<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 9<br />

O2 Werk LINDE Gas / „VOEST Alpine“<br />

Linz, Austria<br />

1997 & 2000<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-163 E04<br />

4,600 kW<br />

6,000 V<br />

Air/Water<br />

2<br />

Compressor VK32-6<br />

Low starting current<br />

5xFLC<br />

Highest efficiency<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 10<br />

LINDE / „Hassi Messaoud“<br />

Algeria<br />

2001<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-156 D02<br />

2,500 kW<br />

6,000 V<br />

Air/Water<br />

1<br />

Turbo compressor<br />

IP65<br />

Operation in desert<br />

60° C water<br />

temperature<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 11<br />

Siemens / „Infraleuna“<br />

Germany<br />

1997<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-156 D02<br />

1,850 kW<br />

6,000 V<br />

Air/Water<br />

3<br />

Turbo compressor<br />

CVK16-3<br />

Low starting current<br />

Highest efficiency<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 12<br />

MAN / „Dillingen“<br />

Germany<br />

2004<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-110 D04<br />

13,000 kW<br />

6,000 V<br />

Air/Water<br />

1<br />

Turbo compressor<br />

Low starting current<br />

4.3 times FLC at rated<br />

voltage (Vr)<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 13<br />

AIR PRODUCTS / „Steel Mill Gent“<br />

Belgium<br />

2004<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-110 D04<br />

13,600 kW<br />

6,000 V<br />

Air/Water<br />

1<br />

Air separation<br />

Low starting current<br />

3.8xFLC at 100 % Vr<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 14<br />

Solvay / „Banksmeadow“<br />

Australia<br />

1996<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-156 D02<br />

1,550 kW<br />

10,500 V<br />

Air/Water<br />

1<br />

Turbo compressor<br />

Low starting current<br />

(3.9-times at 100 Vr)<br />

Highest efficiency<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 15<br />

VAI / „Feinsint“<br />

Austria<br />

1993<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-156 D02<br />

1,900 kW<br />

6,000 V<br />

Air/Water<br />

2 p<br />

Process air compressor<br />

2-pole motor with lowest<br />

noise level 76 dB<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 16<br />

Axima / „Katri Vala“<br />

Finland<br />

2005<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-171 E04<br />

6,500 kW<br />

10,000 V<br />

Air/Water<br />

5<br />

Turbo compressor<br />

Low noise emission<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 17<br />

Voith / „Condea Augusta“<br />

Sicilia, Italy<br />

2000<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-171 D04<br />

5,500 kW<br />

6,000 V<br />

Water<br />

1piece<br />

Compressor<br />

EEx p T3<br />

Low starting current<br />

(4.4-times at 100 % of<br />

the nominal voltage)<br />

We keep the world in motion.


Air/Water Cooled Motors<br />

<strong>ELIN</strong> Type: HRM (Slip ring motors)<br />

Cooling Method: IC81W (TEAWC)<br />

November 2009


Project:<br />

Location:<br />

Year:<br />

Page 19<br />

PGW Turbo / „POSCO“<br />

Korea<br />

2006<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HRM-090D04<br />

10,000 kW<br />

6,600 V<br />

Air/Water<br />

3<br />

Turbo compressor<br />

Slip ring motor with fluid<br />

starter<br />

Auxiliaries in Ex Type<br />

Automatic short cut<br />

device<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 20<br />

AirLiquide / „Donawitz“<br />

Austria<br />

2006<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HRM-080 Z04<br />

5,500 kW<br />

6,000 V<br />

Air/Water<br />

1<br />

Turbo compressor<br />

Slip ring motor with fluid<br />

starter<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 21<br />

Biochemie Kundl / „Compressor 9“<br />

Austria<br />

1998<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HRM-056 D04<br />

2,250 kW<br />

6,000 V<br />

Air/Water<br />

1 piece<br />

Turbo compressor<br />

Maximum efficiency<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 22<br />

Jungbunzlauer / „Colborne“<br />

Canada<br />

2001<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HRM-063 C04<br />

2,000 kW<br />

13,800 V<br />

Air/Water<br />

3<br />

Turbo compressor<br />

CVK40-2<br />

CSA-design<br />

13.8 kV Slip ring<br />

motor<br />

We keep the world in motion.


Water Jacked Cooled Motors<br />

<strong>ELIN</strong> Type: HCZ (water jacked cooled)<br />

Cooling Method: IC7A0W7 (TEWC)<br />

November 2009


Project:<br />

Location:<br />

Year:<br />

Page 24<br />

„Purification Plant Hetlingen“<br />

Switzerland<br />

2000<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

MCZ-540 E02<br />

630 kW<br />

690 V<br />

water jacked cooled<br />

4<br />

Turbo compressor<br />

Highest efficiency<br />

Low noise emission<br />

Lowest friction losses<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 25<br />

AXIMA / „Refrigeration AG“<br />

Climespace Tokyo<br />

2005<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HCZ-545 L02<br />

1,250 kW<br />

5,500 V<br />

water jacket cooled<br />

8<br />

Turbo compressor<br />

Smoothness of running<br />

Grade B<br />

Balancing quality G1.6<br />

Low noise emission 77<br />

dB<br />

We keep the world in motion.


Air/Air Cooled Motors<br />

<strong>ELIN</strong> Type: HKL<br />

Cooling Methode: IC611 (TEAAC)<br />

November 2009


Project:<br />

Location:<br />

Year:<br />

Page 27<br />

VAI / „Russland“<br />

Russia<br />

2004<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKL-115 D04<br />

2,000 kW<br />

6,000 V<br />

Air cooled<br />

4<br />

Blower for steel plant<br />

High load moment of<br />

inertia J= 1300 kg/m²<br />

Environment<br />

temperature<br />

from -30 up to 40 °C<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 28<br />

Burckhardt Compressions / „Isle of Grain“<br />

Isle of Grain, Great Britain<br />

2006<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKL-171 D16<br />

1,300 kW<br />

6,600 V<br />

Air cooled (IC611)<br />

2<br />

BCA reciprocating<br />

compressor<br />

EEx nA in accordance<br />

with ATEX<br />

Degree of protection<br />

IP56<br />

Low noise emission 80<br />

dB(A)<br />

We keep the world in motion.


Air/Air Cooled Motors<br />

<strong>ELIN</strong> Type: HKG<br />

Cooling Methode: IC411 (TEFC)<br />

November 2009


Project:<br />

Location:<br />

Year:<br />

Page 30<br />

Siemens /„Purification Plant Linz Asten“<br />

Austria<br />

2000<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKG-545 C04<br />

630 kW<br />

6,300 V<br />

Air<br />

2<br />

Turbo compressor<br />

KA22SV<br />

Compressor for<br />

biological clarification<br />

We keep the world in motion.


Air/Air Cooled Motors<br />

<strong>ELIN</strong> Type: HKR<br />

Cooling Method: IC511 (TEPV)<br />

November 2009


Project:<br />

Location:<br />

Year:<br />

Page 32<br />

MAN / „Rasfuel“<br />

Qatar<br />

2005<br />

Courtesy of MAN Turbo<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights<br />

HKR-110 Z02<br />

3,075 kW<br />

6,600 V<br />

Air<br />

3<br />

Turbo compressor<br />

EExp II A T3<br />

Low noise level at<br />

2-pole Motor 83 dB(A)<br />

Starting current<br />

4.4-times FLC<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 33<br />

Siemens / „Repsol Ensenada“<br />

Mexico<br />

2006<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKR-110 B04<br />

3,000 kW<br />

6,600 V<br />

Air<br />

1<br />

Siemens Compressor<br />

STC- GV 32-2<br />

Low noise emission<br />

EEx nA protection<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 34<br />

MAN Turbo / BP /„NEREWAS“<br />

Netherlands<br />

2007<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKR-110 B02<br />

3,300 kW<br />

10,000 V<br />

Air/Air (IC511)<br />

1<br />

MAN Screw<br />

compressor<br />

EExp IIC T3 Zone 2<br />

Low noise level max<br />

83 dB at load<br />

Special requirements<br />

for accessories and<br />

material<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 35<br />

MAN Turbo / „LAVRIFUEL“<br />

Greek<br />

2005<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKR-180 B02<br />

1,275 kW<br />

6,000 V<br />

Air/Air (IC511)<br />

1<br />

MAN Compressor<br />

EExn IIB T3 Zone 2<br />

Low noise level max<br />

82.5 dB at load<br />

EExd Main Terminal<br />

Box<br />

We keep the world in motion.


Explosion-Proof Motors<br />

Protection Methode: Exn, Exe, Exp<br />

November 2009


Project:<br />

Location:<br />

Year:<br />

Page 37<br />

Kobleco / „Borealis Schwechat PP5“<br />

Schwechat (Austria)<br />

2005<br />

Courtesy of ConPackSys<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-163 D02<br />

3,550 kW<br />

10,000 V<br />

Air/Water<br />

1<br />

Compressor Kobleco<br />

M-C-4401X<br />

Highest application<br />

efficiency<br />

Low starting current<br />

4.5xFLC<br />

Low noise emission<br />

80 dB + 3 dB Tolerance<br />

Ex-Protection:<br />

Ex II 2G Ex-pe IIB T3<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 38<br />

Atlas Copco / „Borealis PP“<br />

Schwechat, Austria<br />

2004<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-156 D02<br />

1,800 kW<br />

10,000 V<br />

Air/Water<br />

1<br />

Turbo compressor<br />

Pressurized design<br />

EExp in accordance<br />

with ATEX<br />

Low starting current<br />

4.5xFLC<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 39<br />

Siemens / „Repsol Ensenada“<br />

Mexico<br />

2006<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKR-110 B04<br />

3,000 kW<br />

6,600 V<br />

Air<br />

1<br />

Siemens Compressor<br />

STC- GV 32-2<br />

Low noise emission<br />

EEx nA protection<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 40<br />

MAN / „Rasfuel“<br />

Qatar<br />

2005<br />

Courtesy of MAN Turbo<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights<br />

HKR-110 Z02<br />

3,075 kW<br />

6,600 V<br />

Air<br />

3<br />

Turbo compressor<br />

EExp II A T3<br />

Low noise level at<br />

2-pole Motor 83 dB(A)<br />

Starting current<br />

4.4-times FLC<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 41<br />

Burckhardt / „Borealis PP“<br />

Schwechat, Austria<br />

2004<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-190 C16<br />

1,990 kW<br />

10,000 V<br />

Air/Water<br />

1<br />

Turbo compressor<br />

Pressurized design<br />

EEx p in accordance<br />

with ATEX<br />

Low starting current<br />

4.5xFLC<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 42<br />

Kobelco Japan / „Borealis PP“ / Neste Oil<br />

Schwechat, Austria<br />

2008<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKE-550 L02<br />

930 kW<br />

6,000 V<br />

Air (IC411)<br />

1<br />

Turbo compressor<br />

EExe IIB T3 Zone 1<br />

Highest efficiency<br />

η=97.67 %<br />

Run out max 12.5µm<br />

Shaft vibration max<br />

50µm<br />

Noise level at load<br />

max. 80 dB<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 43<br />

Converteam – RWE DEA / „VOELGAS“<br />

Kreepen, Germany<br />

2007<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKM-171 D04<br />

5,000 kW<br />

3,300 V (Inverter)<br />

Air/Water<br />

3<br />

MAN Turbo<br />

compressor<br />

EExp IIB/C T3 Zone 2<br />

Operation on inverter<br />

High level of<br />

accessories<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 44<br />

MAN Turbo / BP /„NEREWAS“<br />

Netherlands<br />

2007<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKR-B110 B02<br />

3,300 kW<br />

10,000 V<br />

Air/Air (IC511)<br />

1<br />

MAN Screw<br />

compressor<br />

EExp IIC T3 Zone 2<br />

Low noise level max<br />

83 dB at load<br />

Special requirements<br />

for accessories and<br />

material<br />

We keep the world in motion.


Project:<br />

Location:<br />

Year:<br />

Page 45<br />

MAN Turbo / „LAVRIFUEL“<br />

Greek<br />

2005<br />

• Type:<br />

• Power:<br />

• Voltage:<br />

• Cooling:<br />

• Quantity:<br />

• Application:<br />

• Highlights:<br />

HKR-180 B02<br />

1,275 kW<br />

6,000 V<br />

Air/Air (IC511)<br />

1<br />

MAN Compressor<br />

EExn IIB T3 Zone 2<br />

Low noise level max<br />

82.5 dB at load<br />

EExd Main Terminal<br />

Box<br />

We keep the world in motion.