31.07.2015 Views

Sauter - Pneumatic controller RLP100 - TROX

Sauter - Pneumatic controller RLP100 - TROX

Sauter - Pneumatic controller RLP100 - TROX

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TROX</strong> GmbHHeinrich-Trox-Platz47504 Neukirchen-Vluyn,GermanyTel. +49(0)2845 202 0Fax +49(0)2845 202 265www.trox.deE-mail: trox@trox.deRoom pressure <strong>controller</strong><strong>Sauter</strong> RLP 100 F901/915Product informationRLP 100 F901/F915612Areas of applicationThe <strong>Sauter</strong> pneumatic room pressure <strong>controller</strong>RLP 100 F901/F915 is designed for positive or negativepressure control of leak-proof spaces. The room pressurecontrol takes place in cascade with a <strong>Sauter</strong> RLP 100F003 flow volume <strong>controller</strong> that controls the flow volumecontrol unit in the supply or exhaust air. The control for aroom comprises a total of 3 <strong>controller</strong>s.1 Flow volume <strong>controller</strong>RLP 100 F0032 T n adjusting knob (50%)*3 Direction of control action adjuster A/B4 x p adjusting knob, (100%)*5 ∆ p adjusting knob6 Hose connections* Factory settingType Pressure range Mode adjusterRLP 100 F901 -20 bis +20 Pa A BRLP 100 F915 -50 bis +50 Pa Exhaust air supply airCharacteristic curve of the actual value signalPaRoom pressure0.2 0.6 1.0 barActual value signal P MF915 -50 Pa 0 Pa +50 PaF901 -25 Pa 0 Pa +50 Pa345Room pressure <strong>controller</strong>The problem of controlling very leak-proof rooms cannotbe satisfactorily solved using the supply/exhaust airsequence control as measurement and control tolerancesas well as the unknown leakage degree of the room canlead to undesirably high room pressures or to room pressureswith the wrong sign in front of the number. With theroom pressure <strong>controller</strong>, the differential pressure betweenthe room pressure and that of a reference room ismeasured and controlled. The flow volume set value ofthe sequence <strong>controller</strong> is influenced within a limited rangealso by the room pressure <strong>controller</strong> in addition to themaster <strong>controller</strong>Function descriptionRoom pressure <strong>controller</strong>The measurement of the room pressure 1) is made usingthe static differential pressure principle. One measuringpoint for static pressure is installed in the room to be controlledand one in the reference room. If several roomsare connected together in a pressure cascade, the use ofa neutral reference pressure is recommended, e.g. a corridorthat is free from influence of wind and other pressurefluctuations. These pressures (room pressure differences)are measured using a diaphragm pressure transmitter.The actual value of the room pressure can be tapped offas a pneumatic signal P M . The room pressure set value isadjusted or supplied by an external command signal. The<strong>controller</strong> compares the required room pressure with thecurrent actual value. This volume variation then effects achange on the flow volume <strong>controller</strong>.Function of the cascade controlThe flow volume set value is supplied by the room temperature<strong>controller</strong> and limited to min and max . The setvalue is further offset within certain limits through thesecond command signal input (for room pressure<strong>controller</strong>).The damper actuator is controlled corresponding to thevolume variation. The flow volume <strong>controller</strong>s are usedtogether with Trox actuators. The adaptation of the <strong>controller</strong>to the damper actuator direction of control action(NZ/NO) is made in the factory.1) The room pressure difference is simplified in this documentto room pressure13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!