31.07.2015 Views

Sauter - Pneumatic controller RLP100 - TROX

Sauter - Pneumatic controller RLP100 - TROX

Sauter - Pneumatic controller RLP100 - TROX

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>TROX</strong> GmbHHeinrich-Trox-Platz47504 Neukirchen-Vluyn,GermanyTel. +49(0)2845 202 0Fax +49(0)2845 202 265www.trox.deE-mail: trox@trox.deRoom temperature <strong>controller</strong>(PN 21, DW)Operating pressuresupply1.3 bar1 6RLP 100 F0031 6RLP 100 F003Parallel <strong>controller</strong>Operating mode E, MConstant flow volume controlOperating pressuresupply1.3 barRoom temperature<strong>controller</strong>, DWOperating mode E, MFlow volume <strong>controller</strong><strong>Sauter</strong> RLP 100 F003Product informationRoom temperature <strong>controller</strong>The RLP 100 F003 flow volume <strong>controller</strong> should be connectedto exhausting room temperature <strong>controller</strong>s accordingto the hose system diagrams shown opposite. Theflow volume <strong>controller</strong>s exhaust through the input for thecompressed air command signal. In this way, the <strong>controller</strong>can be connected using only one hose ducting The roomtemperature <strong>controller</strong> must be dimensioned for theexhaust flow quantity of the flow volume <strong>controller</strong> (use acut-off relay if necessary,by the customer).Parallel controlSeveral flow volume <strong>controller</strong>s (supply and exhaust air)are mastered in parallel by one room temperature <strong>controller</strong>.If the flow volume control units are all of the same sizeand the min and max adjusting knobs are set to the samevalues, all the units will deliver the same flow volume.If the units have different sizes then they deliver equal-percentage.If several <strong>controller</strong>s are connected to one room temperature<strong>controller</strong>, the sum of the exhaust quantities of all flowvolume <strong>controller</strong>s has to be made allowance for. If thisquantity exceeds the maximum return air capacity of theroom temperature <strong>controller</strong>, a cut-off relay must be used(by the customer).Constant flow volume controlThe RLP 100 F003 flow volume <strong>controller</strong> can also be usedas a constant flow volume <strong>controller</strong>1 6RLP 100 F003Operating mode F10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!