2. Installation2.1 Installation in a concrete slab / floor.North American Product Numbers - 65043,65044 and 65046 / European ProductNumbers 73100.10 S or X, 73125.10 S or X,73150.10 S or X.The body of the Staufix ® SWA should beinstalled level as shown in Illustration 2.Grease and install the included rubbergasket between the Staufix ® SWA body andthe access chamber as shown in Illustration3. As seen in Illustration 4, the cover of theStaufix ® SWA is completely adjustable. Thiscover can be raised or lowered to meet floorheights, tilted laterally to meet grades in thefloor and rotated to match floor patterns.2.2 Deep installation in a concrete slab /floor.For deep installation depths use theextension section (North American Option -4 / European Product Number 83070, adds7 inches / 180mm). If installing an extensionsection make sure to grease its rubbergasket. If more than one extension sectionis needed, be sure that the valve is notinstalled so deep that access to the valve forinspection, maintenance or use is hindered.Illus. 3Illus. 4Illus. 5Illus. 2Everything for drainage 4

2. Installation2.3 Installations subject to groundwaterThere are certain circumstances where theupward force of groundwater can penetratethrough slab installed fixtures and causemoisture problems. The KESSEL Staufix ®SWA provides protection against the upwardforce of groundwater by including thewater barrier (North American Option -5 /European Product Number 83019 (rubberbarrier) and Product Number 83018(flange)) during installation. This barrier issimply placed between the body of theStaufix ® SWA and the flange which is thenbolted tight by the included bolts as shownin Illus. 6.2.4 Installation in an exposed /suspended pipeNorth American Product Numbers 65053,65054 and 65056 / European ProductNumbers 73100.10, 73125.10 and73150.10.The Staufix ® SWA valve designed to beinstalled in an exposed / suspended pipecomes ready to be installed in a properlysloped drainage pipe. This valve is equippedwith a see-thru, easily removable protectivecover.2.5 UpgradabilityAll of the KESSEL Staufix ® SWAs areupgradable to either the KESSEL Staufix ®FKA electronic backwater valve with opticalprobe, motorized flap and control unit or thePumpfix ® F electronic backwater valve withoptical probe, intregrated sewage pump andcontrol unit. In preparation for a futureupgrading, when installing a Staufix ® SWA aDN 50 or 1.5 inch DWV Sched 40 PVC pipeshould be run under the floor from the backwatervalve to a nearby power source so thatfuture electrical connections can easily bemade. An example of this preparation can beseen in Illus. 1 and Illus. 5.ATTENTION:Make sure that no cables or otherobjects impair the movement of the manualclosure lever or interfere with the operation,inspection or maintenance of the valve.Illus. 6Illus. 7FlangeFlangeRubber barrierRubber barrier5Everything for drainage

2. Installation2.3 Installations subject to groundwaterThere are certain circumstances where theupward force of groundwater can penetratethrough slab installed fixtures and causemoisture problems. The <strong>KESSEL</strong> Staufix ®<strong>SWA</strong> provides protection against the upwardforce of groundwater by including thewater barrier (North American Option -5 /European Product Number 83019 (rubberbarrier) and Product Number 83018(flange)) during installation. This barrier issimply placed between the body of theStaufix ® <strong>SWA</strong> and the flange which is thenbolted tight by the included bolts as shownin Illus. 6.2.4 Installation in an exposed /suspended pipeNorth American Product Numbers 65053,65054 and 65056 / European ProductNumbers 73100.10, 73125.10 and73150.10.The Staufix ® <strong>SWA</strong> valve designed to beinstalled in an exposed / suspended pipecomes ready to be installed in a properlysloped drainage pipe. This valve is equippedwith a see-thru, easily removable protectivecover.2.5 UpgradabilityAll of the <strong>KESSEL</strong> Staufix ® <strong>SWA</strong>s areupgradable to either the <strong>KESSEL</strong> Staufix ®FKA electronic backwater valve with opticalprobe, motorized flap and control unit or thePumpfix ® F electronic backwater valve withoptical probe, intregrated sewage pump andcontrol unit. In preparation for a futureupgrading, when installing a Staufix ® <strong>SWA</strong> aDN 50 or 1.5 inch DWV Sched 40 PVC pipeshould be run under the floor from the backwatervalve to a nearby power source so thatfuture electrical connections can easily bemade. An example of this preparation can beseen in Illus. 1 and Illus. 5.ATTENTION:Make sure that no cables or otherobjects impair the movement of the manualclosure lever or interfere with the operation,inspection or maintenance of the valve.Illus. 6Illus. 7FlangeFlangeRubber barrierRubber barrier5Everything for drainage

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!