6.4 Inspection of toothed racksEach time the toothed racks are inspected they must be cleaned and relubricated.6.5 Chain repairWhen repairing chains, only original parts may be used. The rivet heads must beground off before dismounting. In this way damages caused by driving the boltthrough the intermediate plate or the inner link in the hole section are avoided.Removed bolts and plates must not be reused.6.6 Changing gear oilmAbsolute care must be taken that the oil cannot be spilled into the sewer or onto thesoil. Waste oil must be securely stored until its proper disposal.Draining the oil:– Place an oil pan under thetransmission.– Open oil drain plug (2) on the bottomside of the transmission and allow theoil to drain.Refilling oil:A– Screw in oil drain plug (2) and tighten.– Open oil check and filler plug (1) at thetop side of the transmission.– Fill new transmission oil up to the oilcheck opening.– Screw in oil check and filler plug (1).Because of the proper disposal andpossibly required special tools and skillsthe transmission and hydraulic oilchange as well as changing brake fluidand filters should be performed by thecustomer service.1102.GBF 10