31.07.2015 Views

EFXac 100/125 - Jungheinrich

EFXac 100/125 - Jungheinrich

EFXac 100/125 - Jungheinrich

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

a) Check wheel nuts for tight seat for the first time after ca. <strong>100</strong> operating hours,retighten, if required.b) Check hydraulic connections for leaks for the first time after ca. <strong>100</strong> operating hours,retighten, if required.c) 1st change after 500 operating hours.d) Change hydraulic hoses after six years of operation.Maintenance intervalsStandard = t W1M3Electr. system 7.1 Check the leakage of static charges t7.2 Performance check t7.3 Check cables for secure connection and damage t7.4 Check cable guides for function and damage t7.5 Check the warning facilities and safety switches forproper functiont7.6 Check sensors for secure attachment, damages,cleanliness, and functiont7.7 Check function of instruments and indicators t7.8 Check contactors and relays, replace wearing parts ifnecessaryt7.9 Check fuses for correct amperage tElectric 8.1 Check the motor for secure attachmentmotors:tBattery: 9.1 Check acid density, acid level, and cell voltage t9.2 Check terminals for secure attachment and applygreaset9.3 Clean battery plug connections, check for tight seat t9.4 Check battery cables for damage and replace, ifnecessarytM6M12AThe maintenance intervals refer to normal service conditions. In case of aggravatedconditions, the intervals must be reduced as required.1102.GBF 5