6 Monitoring function and safety devices6.1 Emergency stop facilityWhen the automatic emergency stop facility is triggered (e. g. when guidance is lostor the electrical steering fails) the truck is decelerated to standstill. Before bringing thetruck into service again the cause for the error (error code in display) must bedetermined and, depending on the cause, qualified maintenance personnel musteliminate the failure.6.2 Drive cut-off with override (o)AIf one of the criteria for drive cut-off is fulfilled the truck is decelerated to standstill.After that the continuation of travel is possible at inching speed by pushing theoverride button continuously.The pushbutton for drive cut-off is located in the control panel.6.3 Lift cut-off with override (o)fAAIf required by the local conditions, an automatic lift cut-off, which is triggered at acertain lifting height, can be built into the truck for safety reasons.Overriding the lift cut-off requires special attention of the driver, in order to recogniseobstacles when the mast is extended.– By continuously pushing button “Override lift cut-off” the lift cut-off is disabled.– The indicator “Lift cut-off OFF” illuminates.When lowering below the lift cut-off height the lift cut-off is enabled again.The pushbutton for lift cut-off is located in the control panel.1102.GBE 36