31.07.2015 Views

Grease separator

Grease separator

Grease separator

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DescriptionKESSEL Version „G“ <strong>separator</strong>s are designed according to EN 1825-1.These <strong>separator</strong>s distinguish themselves through their ease of installationand nearly maintenance free characteristics.According to DIN V 4040-2, the complete contents of the <strong>separator</strong>should be emptied, the unit cleaned and refilled with clean cold waterevery fourteen days or at a minimum of every month. To empty thecontents of the <strong>separator</strong> the cover needs to be removed. The <strong>separator</strong>is then completely emptied and cleaned by the disposal truck.not possible, heated drainage piping should be used between the fixturesand the <strong>separator</strong>. It is important to note that the inlet level of the<strong>separator</strong> must always be located below the frost level. This can beaccomplished by the use of the vertically adjustable upper section andby the use of an extension section when necessary. The <strong>separator</strong>manhole covers for load classes B (12.5 ton) and D (40.0 ton) are odortight and secured with bolts according to EN 124.The underground <strong>separator</strong> should be located as close as possible tothe fixtures (drains) to which it is connected. In the case where locatingthe <strong>separator</strong> in close proximity to the fixtures which it drains isInstallation hintsThe underground <strong>separator</strong> must be placed on a firm and level base ofcompacted sand or gravel which will be able to support the predeterminedloads.The <strong>separator</strong> should then be placed in the prepared hole and filled withwater to the outlet level.The hole should be then filled and thoroughly compacted at equal increments(approx 0.5 meters) with sand or gravel. For <strong>separator</strong>s needingto withstand heavy tractor trailer loads (up to 40.0 ton), please consultKESSEL for installation instructions.Connect the inlet and outlets of the <strong>separator</strong> to the drainage piping.Separators for underground installation below the groundwater level areavailable from KESSEL upon request.NoticeThe KESSEL Version ”G” underground <strong>separator</strong> should be installedonly in areas where:• the release of strong and aggressive odors will not pose a problem• accessing the <strong>separator</strong> with the disposal hose of the disposal truckwill not cause problems or inconveniences.Page 29

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!