31.07.2015 Views

KESSEL Grease separator “M” NG 2, 4, 7 and 10 For installation in ...

KESSEL Grease separator “M” NG 2, 4, 7 and 10 For installation in ...

KESSEL Grease separator “M” NG 2, 4, 7 and 10 For installation in ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5. Disposal for grease <strong>separator</strong> acc. to. DIN 40405.1 <strong>For</strong> <strong>separator</strong>s with manually automated disposalSeparators <strong>NG</strong> 2, <strong>NG</strong> 4, <strong>NG</strong> 7 <strong>and</strong> <strong>NG</strong> <strong>10</strong> acc. to DIN 4040Program Function Valve sett<strong>in</strong>gPump runn<strong>in</strong>g time <strong>in</strong> secondsstep<strong>NG</strong> 2 <strong>NG</strong> 4 <strong>NG</strong> 7 <strong>NG</strong> <strong>10</strong>1 partial “Leeren” / empty 40 60 80 120empty2 mix “Mischen” / mix 120 180 200 3603 empty “Leeren” / empty 120 180 300 3604 fill “Mischen” / mix <strong>10</strong>0 <strong>10</strong>0 140 2005 mix “Mischen” / mix 120 120 160 2406 empty “Leeren” / empty 30 30 60 607 fill “Spülen” / r<strong>in</strong>se <strong>10</strong>0 <strong>10</strong>0 140 2008 r<strong>in</strong>se “Spülen” / r<strong>in</strong>se 60 90 <strong>10</strong>0 1809 empty “Leeren” / empty 30 30 60 60<strong>10</strong> fill “Spülen” / r<strong>in</strong>se 60 <strong>10</strong>0 140 20011 r<strong>in</strong>se “Spülen” / r<strong>in</strong>se 60 90 <strong>10</strong>0 18012 empty “Leeren” / empty 30 30 60 6013 fill “Leeren” / empty 300 420 500 <strong>10</strong>00Pump Valve warm Valve cold waterH<strong>in</strong>twateron off off Let the pump run until waterlevel has dropped by approx.30 cmon off offon off off until the pump runs dryoff on off approx. 25 cm fill<strong>in</strong>g levelon off offon off off until the pump runs dryoff on off approx. 25 cm fill<strong>in</strong>g levelon off offon off off until the pump runs dryoff on off approx. 25 cm fill<strong>in</strong>g levelon off offon on off until the pump runs dryoff off on upntil <strong>separator</strong> overflow levelTime sett<strong>in</strong>gs can also be customized depend<strong>in</strong>g on pump<strong>in</strong>g height, temperature or waterpressures. Flow rate through a DN 25 solenoid valve is 23 m3/hour.9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!