31.07.2015 Views

ETSI EN 300 440-1 V1.3.1 ETSI EN 300 440-2 V1.1.2 Measurement

ETSI EN 300 440-1 V1.3.1 ETSI EN 300 440-2 V1.1.2 Measurement

ETSI EN 300 440-1 V1.3.1 ETSI EN 300 440-2 V1.1.2 Measurement

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X<strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong><strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2 <strong>V1.1.2</strong><strong>Measurement</strong> and Test ReportForDongGuan City FLYSKY Remote Model Co., Ltd.No.41 Road West, BanHu Village, HuangJiang Town, DongGuan City,GuangDong Porvince, ChinaReport Concerns:Original ReportEquipment Type:9ch radio control systemModel:Report No.:Test/Witness Engineer:FS-TH9XSTR07108045E-1Lahm PengTest Date: 2007-10-17 to 2007-10-24Prepared By:Shenzhen SEM.Test Compliance Service Co., Ltd.Room 609-610, Baotong Building, Baomin 1 st Road, BaoanDistrict, Shenzhen, Guangdong, P.R.C. (518133)Approved & Authorized By:Jandy So / PSQ ManagerNote: This test report is limited to the above client company and the product model only. It maynot be duplicated without prior permitted by SEM.Test Compliance Service Co., Ltd.REPORT NO.: STR07108045E-1 PAGE 1 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XTABLE OF CONT<strong>EN</strong>TS1 G<strong>EN</strong>ERAL INFORMATION ..................................................................................................................................... 31.1 PRODUCT DESCRIPTION FOR EQUIPM<strong>EN</strong>T UNDER TEST (EUT) .........................................................................31.2 TEST STANDARDS ..............................................................................................................................................31.3 RELATED SUBMITTAL(S)/GRANT(S)...................................................................................................................41.4 TEST METHODOLOGY........................................................................................................................................41.5 TEST FACILITY...................................................................................................................................................41.6 EUT EXERCISE SOFTWARE................................................................................................................................41.7 BASIC TEST SETUP BLOCK DIAGRAM................................................................................................................51.8 ACCESSORIES EQUIPM<strong>EN</strong>T LIST AND DETAILS...................................................................................................51.9 EUT CABLE LIST AND DETAILS.........................................................................................................................52 SUMMARY OF TEST RESULTS.............................................................................................................................. 63. EQUIVAL<strong>EN</strong>T ISOTROPICALLY RADIATED POWER ..................................................................................................... 73.1 MEASUREM<strong>EN</strong>T UNCERTAINTY..........................................................................................................................73.2 STANDARD APPLICABLE ....................................................................................................................................73.3 TEST EQUIPM<strong>EN</strong>T LIST AND DETAILS.................................................................................................................73.4 TEST PROCEDURE ..............................................................................................................................................73.5 <strong>EN</strong>VIRONM<strong>EN</strong>TAL CONDITIONS..........................................................................................................................93.6 SUMMARY OF TEST RESULTS.............................................................................................................................9S.G. READING.................................................................................................................................................................... 94. PERMITTED RANGE OF OPERATING FREQU<strong>EN</strong>CIES.................................................................................................. 104.1 APPLICABLE STANDARD ..................................................................................................................................104.2 TEST EQUIPM<strong>EN</strong>T LIST AND DETAILS...............................................................................................................104.3 TEST PROCEDURE ............................................................................................................................................104.4 TEST RESULTS/PLOTS ......................................................................................................................................115. SPURIOUS EMISSIONS................................................................................................................................................. 125.1 MEASUREM<strong>EN</strong>T UNCERTAINTY........................................................................................................................125.2 LIMIT OF SPURIOUS EMISSIONS .......................................................................................................................125.3 TEST EQUIPM<strong>EN</strong>T LIST AND DETAILS...............................................................................................................125.4 TEST PROCEDURE ............................................................................................................................................125.5 <strong>EN</strong>VIRONM<strong>EN</strong>TAL CONDITIONS........................................................................................................................135.6 SUMMARY OF TEST RESULTS/PLOTS................................................................................................................136. DUTY CYCLE .............................................................................................................................................................. 166.1 APPLICABLE STANDARD ..................................................................................................................................166.2 TEST EQUIPM<strong>EN</strong>T LIST AND DETAILS...............................................................................................................166.3 TEST PROCEDURE ............................................................................................................................................166.4 <strong>EN</strong>VIRONM<strong>EN</strong>TAL CONDITIONS........................................................................................................................166.5 SUMMARY OF TEST RESULTS/PLOTS................................................................................................................167. RECEIVER SPURIOUS EMISSIONS............................................................................................................................... 187.1 MEASUREM<strong>EN</strong>T UNCERTAINTY........................................................................................................................187.2 LIMIT OF SPURIOUS EMISSIONS .......................................................................................................................187.3 TEST EQUIPM<strong>EN</strong>T LIST AND DETAILS...............................................................................................................187.4 TEST PROCEDURE ............................................................................................................................................185.5 <strong>EN</strong>VIRONM<strong>EN</strong>TAL CONDITIONS........................................................................................................................185.6 TEST RESULTS/DATA........................................................................................................................................18EXHIBIT 1- PRODUCT LABELING......................................................................................................................... 20PROPOSED CE LABEL FORMAT..............................................................................................................................20PROPOSED LABEL LOCATION ON EUT...................................................................................................................20EXHIBIT 2 - EUT PHOTOGRAPHS.......................................................................................................................... 21EXHIBIT 3 - TEST SETUP PHOTOGRAPHS.......................................................................................................... 27EXHIBIT 4 –SCHEMATICS............................................................................................................................................ 29EXHIBIT 5 –USERS MANUAL.................................................................................................................................. 29REPORT NO.: STR07108045E-1 PAGE 2 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X1 G<strong>EN</strong>ERAL INFORMATION1.1 Product Description for Equipment Under Test (EUT)Client InformationApplicant:Address of applicant:DongGuan City FLYSKY Remote Model Co., Ltd.No.41 Road West, BanHu Village, HuangJiang Town,DongGuan City, GuangDong Province, ChinaManufacturer:Address of applicant:DongGuan City FLYSKY Remote Model Co., Ltd.No.41 Road West, BanHu Village, HuangJiang Town,DongGuan City, GuangDong Province, ChinaGeneral Description of E.U.TItemsDescriptionEUT Description:9ch radio control systemTrade Name:FLYSKYModel No.:FS-TH9XRated Voltage:DC 12V BatteryOutput Power:1mWFrequency Range:2402MHzNo. of Channel:9 Channel with different encode for identificationAntenna Type:Unique coupling antennaSize:21.0x19.0x6.0 cmFor more information refer to the circuit diagram form and the user’s manual.The test data is gathered from a production sample, provided by the manufacturer.1.2 Test StandardsThe following report is prepared on behalf of the DongGuan City FLYSKY Remote Model Co., Ltd. inaccordance with <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2 <strong>V1.1.2</strong>, Electromagnetic compatibility and Radio spectrum Matters(ERM);Short range devices; Radio equipment to be used in the 1 GHz to 40 GHz frequency range; Part 2:Harmonized <strong>EN</strong> under article 3.2 of the R&TTE Directive.The objective of the manufacturer is to determine compliance with <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2 <strong>V1.1.2</strong>, Electromagneticcompatibility and Radio spectrum Matters (ERM); Short range devices; Radio equipment to be used in the 1 GHzto 40 GHz frequency range; Part 2: Harmonized <strong>EN</strong> under article 3.2 of the R&TTE Directive.Maintenance of compliance is the responsibility of the manufacturer. Any modification of the product maybewhich result in lowering the immunity should be checked to ensure compliance has been maintainedREPORT NO.: STR07108045E-1 PAGE 3 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X1.3 Related Submittal(s)/Grant(s)No Related Submittal(s).1.4 Test MethodologyAll measurements contained in this report were conducted with <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong>, Electromagneticcompatibility and Radio spectrum Matters (ERM); Short Range Devices (SRD); Radio equipment to be used inthe 1 GHz to 40 GHz frequency range; Part 1: Technical characteristics and test methods.The equipment under test (EUT) was configured to measure its highest possible emission level. The test modeswere adapted accordingly in reference to the Operating Instructions.1.5 Test FacilityThe Laboratory has been registered and fully described in a report filed with the (FCC) Federal CommunicationsCommission. The acceptance letter from the FCC is maintained in files which the Registration No.: 759397.<strong>Measurement</strong> required was performed at laboratory of Solid Industrial Co., Ltd. at 333 Bulong Highway BujiLonggang, Shenzhen, Guangdong, China.1.6 EUT Exercise SoftwareThe EUT exercise program used during the testing was designed to exercise the system components. The testsoftware is started while the whole system is on.REPORT NO.: STR07108045E-1 PAGE 4 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X1.7 Basic Test Setup Block DiagramAntennaTower1m-4m3mEUTTurntableTable1.5mTo EMI ReceiverGround Plane1.8 Accessories Equipment List and DetailsManufacturer Description Model Serial Number/ / / /1.9 EUT Cable List and DetailsCable Description Length (M) Shielded/UnshieldedWith Core/WithoutCore/ / / /REPORT NO.: STR07108045E-1 PAGE 5 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X2 SUMMARY OF TEST RESULTS<strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2 <strong>V1.1.2</strong> Description of Test Result§4.1.1 Equivalent Isotropically Radiated Power Compliant§4.1.2 Permitted Range of Operating Frequencies Compliant§4.1.3 Spurious Emissions Compliant§4.1.4 Duty Cycle Compliant§4.2.4 Receiver Spurious Emissions CompliantREPORT NO.: STR07108045E-1 PAGE 6 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X3. Equivalent Isotropically Radiated Power3.1 <strong>Measurement</strong> UncertaintyBase on NIS 81, The Treatment of Uncertainty in EMC <strong>Measurement</strong>s, the best estimate of the uncertainty of anyradiation emissions measurement is + 3.0 dB.3.2 Standard ApplicableAccording to <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong> section 7.1.3, the effective radiated power shall not exceed the powerclass value given in following table:The power class is 8. In accordance with ERC/REC 70-03, the maximum allowable power is 10 mW e.i.r.pFor equipment with an integral antenna and no RF connector, measurements under extreme conditions are notrequired.3.3 Test Equipment List and DetailsDescription Manufacturer ModelSerialNumberCal. Date Due. DateEMI TestReceiverRohde & Schwarz ESI26 838786/013 2007-1-25 2008-1-24Signal Generator Rohde & Schwarz SMR20 100047 2007-1-25 2008-1-24Bilog Antenna Chase CBL6112B 2591 2007-1-25 2008-1-24Horn Antenna Schwarzbeck VUBA9117 115 2007-1-25 2008-1-243mSemi-anechoicchamberAlbatross Projects 9X6X6 ---- 2006-3-21 2008-3-203.4 Test ProcedureOn a test site, selected from annex A, the equipment shall be placed at the specified height on a support, asspecified in annex A, and in the position closest to normal use as declared by the manufacturer.REPORT NO.: STR07108045E-1 PAGE 7 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XThe test antenna shall be oriented initially for vertical polarization and shall be chosen to correspond to thefrequency of the transmitter.The output of the test antenna shall be connected to the measuring receiver.The transmitter shall be switched on, if possible, without modulation and the measuring receiver shall be tuned tothe frequency of the transmitter under test.In case of pulse modulation equipment where it is not possible to make the measurement in the absence ofmodulation, the measurement shall be carried out by the use of a measuring receiver with bandwidth as stated insubclause 6.6 and peak detector set in accordance with the specification of CISPR 16 [8] section one for the bandsC and D.The test antenna shall be raised and lowered through the specified range of height until a maximum signal level isdetected by the measuring receiver.The transmitter shall then be rotated through 360° in the horizontal plane, until the maximum signal level isdetected by the measuring receiver.The test antenna shall be raised and lowered again through the specified range of height until a maximum signallevel is detected by the measuring receiver.The maximum signal level detected by the measuring receiver shall be noted.The transmitter shall be replaced by a substitution antenna as defined in annex A, subclause A.1.5.The substitution antenna shall be orientated for vertical polarization and the length of the substitution antennashall be adjusted to correspond to the frequency of the transmitter.The substitution antenna shall be connected to a calibrated signal generator.If necessary, the input attenuator setting of the measuring receiver shall be adjusted in order to increase thesensitivity of the measuring receiver.The test antenna shall be raised and lowered through the specified range of height to ensure that the maximumsignal is received.The input signal to the substitution antenna shall be adjusted to the level that produces a level detected by themeasuring receiver, that is equal to the level noted while the transmitter radiated power was measured, correctedfor the change of input attenuator setting of the measuring receiver.The input level to the substitution antenna shall be recorded as power level, corrected for any change of inputattenuator setting of the measuring receiver.The measurement shall be repeated with the test antenna and the substitution antenna orientated for horizontalpolarization.The measure of the effective radiated power is the larger of the two levels recorded at the input to the substitutionREPORT NO.: STR07108045E-1 PAGE 8 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9Xantenna, corrected for gain of the substitution antenna if necessary.3.5 Environmental ConditionsTemperature: 18 °CRelative Humidity: 45%ATM Pressure:1019 mbar3.6 Summary of Test ResultsFrequencyIndicated Table Test AntennaMeterReadingSubstitutedS.G. readingAntenna Cable Absolute <strong>EN</strong><strong>300</strong> <strong>440</strong>Angle Height Polar Level Gain Loss Level LimitMHz dBuV/m Degree Meter H/V dBm dBi dB dBm dBm2402 88.6 45 1.0 V -19.05 9.8 1.95 -11.2 102402 81.8 60 1.0 H -25.65 9.8 1.95 -17.8 10REPORT NO.: STR07108045E-1 PAGE 9 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X4. Permitted Range of Operating Frequencies4.1 Applicable StandardTest is carried out according to <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong> section 7.2. and section 5.4 for test condition requirements.The frequency range of the equipment is determined by the lowest and highest frequencies occupied by the powerenvelope in accordance with CEPT/ERC Recommendation 74-01 [2].fH is the highest frequency of the power envelope, it is the frequency furthest above the frequency of maximumpowerwhere the output power drops below the level of –74,8 dBm/Hz spectral power density (-30 dBm if measured in a30 kHz reference bandwidth) eirp.fL is the lowest frequency of the power envelope; it is the frequency furthest below the frequency of maximumpowerwhere the output power drops below the level of –74,8 dBm/Hz spectral power density (-30 dBm if measured in a30 kHz reference bandwidth) eirp.For tests at extreme temperatures, measurements shall be made in accordance with the procedures specified inclause 5.4.1.1, at the upper and lower temperatures of one of the following ranges:- Category I (General): -20°C to +55°C;- Category II (Portable): -10°C to +55°C;- Category III (Equipment for normal indoor use): 0°C to +55°C.The extreme test voltages for equipment to be connected to an ac mains source shall be the nominal mains voltage±10 %.4.2 Test Equipment List and DetailsManufacturer Description ModelSerialNumberCal. Date Due. DateEMI TestReceiverRohde & Schwarz ESI26 838786/013 2007-01-25 2008-01-24GONGW<strong>EN</strong>Moisture TestChamberGDS-150 SEMT-0013 2007-06-30 2008-06-29LW DC Power Supply APR-<strong>300</strong>3 N/A 2007-06-30 2008-06-294.3 Test ProcedureTest is carried out according to <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong> section 7.2.2.REPORT NO.: STR07108045E-1 PAGE 10 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X4.4 Test Results/PlotsThe frequency range lies within the band 2,4 GHz to 2,4835 GHz (fL > 2,4 GHz and fH < 2,4835 GHz). Full fitthe standard requirements.Test ConditionsFrequency (MHz)At -30dBm/30KHz(eirp)FL at Low CH FH at High CH>2400MHz


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X5. Spurious Emissions5.1 <strong>Measurement</strong> UncertaintyBased on NIS 81, The Treatment of Uncertainty in EMC <strong>Measurement</strong>s, the best estimate of the uncertainty of aradiation emissions measurement is +3.0 dB.5.2 Limit of Spurious EmissionsState47MHz to 74MHz87.5 to 118MHz174MHz to 230MHz470MHz to 862MHzOther frequencies ≤1000MHzFrequencies >1000MHzOperating 4.0nW 250nW 1.0μWStandby 2nW 2nW 20nWFor equipment with an integral antenna and no RF connector, measurements under extreme conditions are notrequired.5.3 Test Equipment List and DetailsDescription Manufacturer ModelSerialNumberCal. Date Due. DateEMI TestReceiverRohde & Schwarz ESI26 838786/013 2007-1-25 2008-1-24Signal Generator Rohde & Schwarz SMR20 100047 2007-1-25 2008-1-24Bilog Antenna Chase CBL6112B 2591 2007-1-25 2008-1-24Horn Antenna Schwarzbeck VUBA9117 115 2007-1-25 2008-1-243mSemi-anechoicchamberAlbatross Projects 9X6X6 ---- 2006-3-21 2008-3-205.4 Test ProcedureTx was placed on a nonmetal table which is 1.5 meter above the grounded reference plane and set to work innormal operation mode. Details refer to <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong> subclause 7.3.5.The EUT was operating at transmitting mode to represent worst case during final qualification test.REPORT NO.: STR07108045E-1 PAGE 12 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X5.5 Environmental ConditionsTemperature: 18 °CRelative Humidity: 45%ATM Pressure:1013 mbar5.6 Summary of Test Results/PlotsFrequencySGReading Height Polar Cable lossAntennaGain Corrected Ampl.<strong>EN</strong><strong>300</strong><strong>440</strong>Limit<strong>EN</strong><strong>300</strong><strong>440</strong>MarginMHz dBm Meter H / V dB dB dBm dBm dBTransmitting (Above 1GHz)4804 -44.8 1.0 H 2.7 10.8 -36.7 -30 -6.74804 -42.0 1.2 V 2.7 10.8 -33.9 -30 -3.97206 -49.0 1.0 H 3.1 11.2 -40.9 -30 -10.97206 -47.0 1.0 V 3.1 11.2 -38.9 -30 -8.99608 -53.6 1.2 H 3.5 12.0 -45.1 -30 -15.19608 -52.7 1.2 V 3.5 12.0 -44.2 -30 -14.2Transmitting (30MHz to 1GHz)800.5 -61.8 1.2 V 3.3 0 -65.1 -54 -11.1146.8 -73.2 1.0 V 1.1 0 -74.3 -36 -38.3438.5 -68.9 1.0 V 2.2 0 -71.1 -36 -35.1147.3 -74.1 1.2 H 1.1 0 -75.2 -36 -39.2438.5 -66.6 1.0 H 2.2 0 -68.8 -36 -32.8196.2 -71.6 1.2 H 1.3 0 -72.9 -54 -18.9Note: Data is corrected with the higher level between 30MHz to 1GHz and above 1GHz, which Emissionsattenuated close to the noise base below the permissible value are not reported.REPORT NO.: STR07108045E-1 PAGE 13 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XSpurious Emission Above 1GHz:REPORT NO.: STR07108045E-1 PAGE 14 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XSpurious Emission Below 1GHz:REPORT NO.: STR07108045E-1 PAGE 15 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X6. Duty Cycle6.1 Applicable StandardTest is conducting under the description of <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong> Section 7.4. Where an acknowledgement isrequired, the additional transmitter on-time shall be included and declared by the manufacturer.6.2 Test Equipment List and DetailsManufacturer Description ModelSerialNumberCal. Date Due. DateAgilentSpectrumAnalyzerE<strong>440</strong>2B US41192821 2007-06-30 2008-06-29GONGW<strong>EN</strong>Moisture TestChamberGDS-150 SEMT-0013 2007-06-30 2008-06-29LW DC Power Supply APR-<strong>300</strong>3 N/A 2007-06-30 2008-06-296.3 Test ProcedureTest is conducting under the description of <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong> Section 7.4.2.6.4 Environmental ConditionsTemperature: 18 °CRelative Humidity: 45%ATM Pressure:1019 mbar6.5 Summary of Test Results/PlotsAs a manual operation device, the duty cycle class 4 up to 100% according to the <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong>section 7.4.2 declared by the manufacture, which the measure result is 24.06%.REPORT NO.: STR07108045E-1 PAGE 16 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XPlot(s) is presented hereinafter as reference:REPORT NO.: STR07108045E-1 PAGE 17 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9X7. Receiver Spurious Emissions7.1 <strong>Measurement</strong> UncertaintyBased on NIS 81, The Treatment of Uncertainty in EMC <strong>Measurement</strong>s, the best estimate of the uncertainty of aradiation emissions measurement is +3.0 dB.7.2 Limit of Spurious EmissionsThe power of any spurious emission shall not exceed 2 nW in the range 25 MHz to 1 GHz and shall not exceed 20nW on frequencies above 1 GHz.7.3 Test Equipment List and DetailsDescription Manufacturer ModelSerialNumberCal. Date Due. DateEMI TestReceiverRohde & Schwarz ESI26 838786/013 2007-1-25 2008-1-24Signal Generator Rohde & Schwarz SMR20 100047 2007-1-25 2008-1-24Bilog Antenna Chase CBL6112B 2591 2007-1-25 2008-1-24Horn Antenna Schwarzbeck VUBA9117 115 2007-1-25 2008-1-243mSemi-anechoicchamberAlbatross Projects 9X6X6 ---- 2006-3-21 2008-3-207.4 Test ProcedureTx was placed on a nonmetal table which is 1.5 meter above the grounded reference plane and set to work innormal operation mode. Details refer to <strong>ETSI</strong> <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>V1.3.1</strong> subclause 7.3.5.The receiver was operating at receiving mode to represent worst case during final qualification test.5.5 Environmental ConditionsTemperature: 18 °CRelative Humidity: 45%ATM Pressure:1013 mbar5.6 Test Results/DataREPORT NO.: STR07108045E-1 PAGE 18 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XFrequencySGReading Height Polar Cable lossAntennaGain Corrected Ampl.<strong>EN</strong><strong>300</strong><strong>440</strong>Limit<strong>EN</strong><strong>300</strong><strong>440</strong>MarginMHz dBm Meter H / V dB dB dBm dBm dBReceiving (Above 1GHz)4804 -70.7 1.5 H 2.7 10.8 -62.6 -57 -5.64804 -71.2 1.6 V 2.7 10.8 -63.1 -57 -6.17206 -72.4 1.5 H 3.1 11.2 -64.3 -57 -7.37206 -72.5 1.5 V 3.1 11.2 -64.4 -57 -7.4Receiving (30MHz to 1GHz)87.5 -64.2 1.6 V 0.9 0 -65.1 -57 -8.191.2 -65.4 1.5 H 0.9 0 -66.3 -57 -9.392.2 -67.5 1.7 V 0.9 0 -68.4 -57 -11.4452.0 -66.4 1.5 H 2.2 0 -68.6 -57 -11.6Note: Data is corrected with the higher level between 25MHz to 1GHz and above 1GHz, which Emissionsattenuated close to the noise base below the permissible value are not reported.REPORT NO.: STR07108045E-1 PAGE 19 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XEXHIBIT 1- PRODUCT LABELINGProposed CE Label FormatSpecifications: Text is Black in color and justified. Labels are printed in indelible ink on permanent adhesivebacking or silk-screened onto the EUT or shall be affixed at a conspicuous location on the EUT.Proposed Label Location on EUTCE Label LocationREPORT NO.: STR07108045E-1 PAGE 20 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XEXHIBIT 2 - EUT PHOTOGRAPHSEUT View 1EUT View 2REPORT NO.: STR07108045E-1 PAGE 21 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XEUT Housing and Board ViewSolder Board-Component View 1REPORT NO.: STR07108045E-1 PAGE 22 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XSolder Board-Component View 2EUT View 1 (Rx)REPORT NO.: STR07108045E-1 PAGE 23 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XEUT Housing and Board ViewSolder Board-Component View 1REPORT NO.: STR07108045E-1 PAGE 24 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XSolder Board-Component View 2Solder Board-Component View 3REPORT NO.: STR07108045E-1 PAGE 25 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XSolder Board-Component View 4REPORT NO.: STR07108045E-1 PAGE 26 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XEXHIBIT 3 - TEST SETUP PHOTOGRAPHSSpurious Emission Test Setup/E.I.R.P. Test SetupREPORT NO.: STR07108045E-1 PAGE 27 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XExtreme Condition Test SetupREPORT NO.: STR07108045E-1 PAGE 28 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2


DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.MODEL: FS-TH9XEXHIBIT 4 –SCHEMATICSEXHIBIT 5 –USERS MANUALREPORT NO.: STR07108045E-1 PAGE 29 OF 29 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-1 <strong>EN</strong> <strong>300</strong> <strong>440</strong>-2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!