31.07.2015 Views

ETSI EN 301 489-1 V1.6.1 ETSI EN 301 489-3 V1.4.1 Measurement ...

ETSI EN 301 489-1 V1.6.1 ETSI EN 301 489-3 V1.4.1 Measurement ...

ETSI EN 301 489-1 V1.6.1 ETSI EN 301 489-3 V1.4.1 Measurement ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

DONGGUAN CITY FLYSKY REMOTE MODEL CO., LTD.Model: FS-TH9X5. Radiated RF-Electromagnetic Field Immunity5.1 Test Equipment List and DetailsDescription Manufacturer ModelSerialNumberCal. Date Due. DateSignal Generator Rohde & Schwarz SMT03 100059 2007-1-26 2008-1-25Voltage Probe Rohde & Schwarz URV5-Z2 100013 2007-1-26 2008-1-25Power Amplifier AR 150W1000 300999 2007-1-26 2008-1-25Power Amplifier AR 25S1G4AM1 305993 2006-3-12 2008-3-11Bilog Antenna Chase CBL6111C 2576 2007-2-26 2008-2-25Anechoic Albatross Projects MCDCchamber---- 2006-3-22 2008-3-215.2 Test ProcedureTest is conducting under the description of IEC 61000-4-3.Test PerformanceTest PerformanceEnvironmental ConditionsTemperature: 24 °CRelative Humidity: 48%ATM Pressure:1010 mbar5.3 <strong>EN</strong>61000-4-3: Continuous Radiated Disturbances Test Data (Transmitter & Receiver)FrequencyRange (MHz)80-1000Front (3 V/m) Rear (3 V/m) Left Side (3 V/m) Right Side (3 V/m)VERT HORI VERT HORI VERT HORI VERT HORIA A A A A A A A1400-2000 A A A A A A A ATest Result: PassREPORT NO.: STR07108045E-2 PAGE 12 OF 22 <strong>EN</strong> <strong>301</strong> <strong>489</strong>-1 <strong>EN</strong> <strong>301</strong> <strong>489</strong>-3