30.07.2015 Views

Raised access floors - Butech

Raised access floors - Butech

Raised access floors - Butech

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installation of RAF for exteriorThe weft of ceramic tiles is determined by the position of the plots. The external RAF slabs rest on these placed on the four corners of the tile, at least, although other positions may beplaced depending on the format size. Plot consumption per m2 depends on the chosen format.The plots are fixed to the support using polyurethane adhesive (P-404). Similarly, and to avoid the tiles shaking, they are adhered to the plot.This system is adapted to the needs of each customer, so in that way and from the project data, butech adapts the external RAF to the particularities of each project.This position ensures good stability to the system and allows greater flexibility in the design of the ceramic weft, and it can design placements with catch joint.The plots are to be placed on a solid support and a maximum gradient of 2%. For indoors, the support must be covered by a waterproof sheet, while outdoors, where no waterproofingsystem is required, the plots may rest directly on the support, if it is solid and stable, with the flap fitted directed toward the drain.This type of pavement in terraces avoids the need of cement mortar screeds for subsequent placement of cement-based tile adhesive. This system avoids the disadvantages of terraces thatmay arise from the traditional placement of direct adhesion. The problems arising from variations in temperature, structural settlements or poor performance of the flooring are eliminated.It also allows obtaining additional benefits as a convenient <strong>access</strong>ibility at any time, allowing correct possible defects in the existing waterproofing and easy start work without theneed for highly specialized, reduced noise transmission and thermal protection of the room beneath the system due to the creation of an air chamber that is in constant ventilation andthe joints between tile and tile 4 mm left open for drainage of water.ReferencesKEA SAP Description HeightB80305010 100005802 basic plot 10 10 mmB80305011 100005803 basic plot 15 15 mmB80305020 100005804 normal plot 50/70 50 - 70 mmB80305021 100005805 normal plot 70/100 70 - 100 mmB80305001 100005794 ultra plot 65/100 65 - 100 mmB80305004 100005797 ultr aplot 100/130 100 - 130 mmB80305003 100005796 ultra plot 130/220 130 - 220 mmB80305005 100005798 ultra plot 220/310 220 - 310 mmB80305006 100005799 ultra plot 310/400 310 - 400 mmB80305007 100005800 ultra plot 400/490 400 - 490 mmB80305008 100005801 ultra plot 490/580 490 - 580 mmAsk for higher heights4243

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!