Installation • Making the Necessary Connections •• Electrical Input RequirementsMaking the Necessary ConnectionsThe RoadRunner requires only two external facilities: electrical AC powerand standard shop pressurized air. The specific requirements are statedbelow as well as on labels inside the RoadRunner. Refer to Figure 2-29 forfacility connection locations.AssembleonACMSiemens 80F, S,HS Series,DSeries &Pansonic CM401,CM402, DT4012EEEEXLF modelSiemens 80F, S,HS Series, D SeriesEFuji QP242,QP351, IP3EFuji NXT & AIM,Panasonic MSF,MCF, MPA,Universal GSM,GenesisSIPLACE X-Series, MYDATAMY Series=AC Power ◦=Air Fitting E=Ethernet =CommunicationsFigure 2-29—RoadRunner Facilities Connection Points.For models where no Communication Connection is indicated, theconnection is on the far side (not visible here).Electrical Input RequirementsThe RoadRunner uses 100-240VAC, 50/60Hz, single phase power. Therequired power is supplied through a single connection on the RoadRunner’send panel. RoadRunner uses a standard IEC-320-C13 power cord. Thepower supply is self-regulating, and requires no special settings for regionalpower requirements.Data I/O • ProLINE-RoadRunner Owner’s Manual • 096-0240 [updated Mar2010] 2—25

Installation • Making the Necessary Connections •• Pneumatic Input RequirementsPower is applied to the internal systems of the RoadRunner when the powerswitch is ON. All power is removed when the power switch is OFF.2!WARNINGElectrical shock hazard. If the main power switch isON, power is applied to the electronic systems ofRoadRunner, regardless of the position of the Emergency-Stopbutton or safety shield. Always turn the mainpower switch OFF before working inside the machine.Pneumatic Input RequirementsRoadRunner requires a pressurized air source connected to theRoadRunner’s end panel. RoadRunner requires clean, dry, oil-free air, atapproximately 5.17 Bars (517 kPa) (75 psi) from an industrial grade compressor.The compressor tank should be of sufficient volume to maintainconstant air pressure at a minimum of 113 Liters/minute (4 cubic feet/minute).A 10 micron filter/separator/regulator must be installed betweenthe compressor and the RoadRunner to extract any contaminants andmoisture before the air enters the machine.Pneumatic Regulator KitProper operation of RoadRunner on SMT machines is accomplished byinstalling a Data I/O Regulator Kit. The kit ensures consistent air pressureand is required for proper RoadRunner operation.Check with Data I/O for your kit availability and installation instructions.The Regulator Kit Model Name (for ordering) for Assembleon Fuji, Panasonic,and Universal is RR-REGULATOR KIT-UF.Figure 2-30—Regulator Kit for Placement Machines(Instructions for RoadRunner/Siemens are listed below.)2—26 Data I/O • ProLINE-RoadRunner Owner’s Manual • 096-0240 [updated Mar2010]

Installation • Making the Necessary Connections •• Pneumatic Input RequirementsPower is applied to the internal systems of the <strong>RoadRunner</strong> when the powerswitch is ON. All power is removed when the power switch is OFF.2!WARNINGElectrical shock hazard. If the main power switch isON, power is applied to the electronic systems of<strong>RoadRunner</strong>, regardless of the position of the Emergency-Stopbutton or safety shield. Always turn the mainpower switch OFF before working inside the machine.Pneumatic Input Requirements<strong>RoadRunner</strong> requires a pressurized air source connected to the<strong>RoadRunner</strong>’s end panel. <strong>RoadRunner</strong> requires clean, dry, oil-free air, atapproximately 5.17 Bars (517 kPa) (75 psi) from an industrial grade compressor.The compressor tank should be of sufficient volume to maintainconstant air pressure at a minimum of 113 Liters/minute (4 cubic feet/minute).A 10 micron filter/separator/regulator must be installed betweenthe compressor and the <strong>RoadRunner</strong> to extract any contaminants andmoisture before the air enters the machine.Pneumatic Regulator KitProper operation of <strong>RoadRunner</strong> on SMT machines is accomplished byinstalling a <strong>Data</strong> I/O Regulator Kit. The kit ensures consistent air pressureand is required for proper <strong>RoadRunner</strong> operation.Check with <strong>Data</strong> I/O for your kit availability and installation instructions.The Regulator Kit Model Name (for ordering) for Assembleon Fuji, Panasonic,and Universal is RR-REGULATOR KIT-UF.Figure 2-30—Regulator Kit for Placement Machines(Instructions for <strong>RoadRunner</strong>/Siemens are listed below.)2—26 <strong>Data</strong> I/O • ProLINE-<strong>RoadRunner</strong> Owner’s <strong>Manual</strong> • 096-0240 [updated Mar2010]

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!