Installation • Making the Necessary Connections •• Electrical Input RequirementsMaking the Necessary ConnectionsThe RoadRunner requires only two external facilities: electrical AC powerand standard shop pressurized air. The specific requirements are statedbelow as well as on labels inside the RoadRunner. Refer to Figure 2-29 forfacility connection locations.AssembleonACMSiemens 80F, S,HS Series,DSeries &Pansonic CM401,CM402, DT4012EEEEXLF modelSiemens 80F, S,HS Series, D SeriesEFuji QP242,QP351, IP3EFuji NXT & AIM,Panasonic MSF,MCF, MPA,Universal GSM,GenesisSIPLACE X-Series, MYDATAMY Series=AC Power ◦=Air Fitting E=Ethernet =CommunicationsFigure 2-29—RoadRunner Facilities Connection Points.For models where no Communication Connection is indicated, theconnection is on the far side (not visible here).Electrical Input RequirementsThe RoadRunner uses 100-240VAC, 50/60Hz, single phase power. Therequired power is supplied through a single connection on the RoadRunner’send panel. RoadRunner uses a standard IEC-320-C13 power cord. Thepower supply is self-regulating, and requires no special settings for regionalpower requirements.Data I/O • ProLINE-RoadRunner Owner’s Manual • 096-0240 [updated Mar2010] 2—25
Installation • Making the Necessary Connections •• Pneumatic Input RequirementsPower is applied to the internal systems of the RoadRunner when the powerswitch is ON. All power is removed when the power switch is OFF.2!WARNINGElectrical shock hazard. If the main power switch isON, power is applied to the electronic systems ofRoadRunner, regardless of the position of the Emergency-Stopbutton or safety shield. Always turn the mainpower switch OFF before working inside the machine.Pneumatic Input RequirementsRoadRunner requires a pressurized air source connected to theRoadRunner’s end panel. RoadRunner requires clean, dry, oil-free air, atapproximately 5.17 Bars (517 kPa) (75 psi) from an industrial grade compressor.The compressor tank should be of sufficient volume to maintainconstant air pressure at a minimum of 113 Liters/minute (4 cubic feet/minute).A 10 micron filter/separator/regulator must be installed betweenthe compressor and the RoadRunner to extract any contaminants andmoisture before the air enters the machine.Pneumatic Regulator KitProper operation of RoadRunner on SMT machines is accomplished byinstalling a Data I/O Regulator Kit. The kit ensures consistent air pressureand is required for proper RoadRunner operation.Check with Data I/O for your kit availability and installation instructions.The Regulator Kit Model Name (for ordering) for Assembleon Fuji, Panasonic,and Universal is RR-REGULATOR KIT-UF.Figure 2-30—Regulator Kit for Placement Machines(Instructions for RoadRunner/Siemens are listed below.)2—26 Data I/O • ProLINE-RoadRunner Owner’s Manual • 096-0240 [updated Mar2010]
- Page 5 and 6: 2 • InstallationUnpacking the Roa
- Page 7 and 8: Glossary • Glossary of TermsAlpha
- Page 9 and 10: 1Overview • RoadRunner is — •
- Page 11 and 12: 1Overview • Overall System Descri
- Page 14 and 15: Overview • Overall System Descrip
- Page 16 and 17: Overview • Overall System Descrip
- Page 18 and 19: Overview • TaskLink’s Handshake
- Page 20 and 21: Overview • Safety •• Safety F
- Page 22 and 23: Specifications [Assembleon]Overview
- Page 24 and 25: Specifications [Fuji NXT, AIM]Overv
- Page 26 and 27: Overview • Specifications [Panaso
- Page 28 and 29: Overview • Specifications [Panaso
- Page 30 and 31: Specifications [Universal GSM]Overv
- Page 32 and 33: Chapter22InstallationFor the Reject
- Page 34 and 35: Installation • Mounting the RoadR
- Page 36 and 37: Installation • Mounting the RoadR
- Page 39 and 40: Installation • Mounting the RoadR
- Page 41 and 42: Installation • Mounting the RoadR
- Page 43 and 44: Installation • Mounting the RoadR
- Page 45 and 46: Installation • Mounting the RoadR
- Page 47 and 48: Installation • Mounting the RoadR
- Page 49 and 50: Installation • Mounting the RoadR
- Page 51 and 52: Installation • Mounting the RoadR
- Page 53 and 54: Installation • Mounting the RoadR
- Page 55: Installation • Installing the Rej
- Page 59 and 60: Installation • Making the Necessa
- Page 61 and 62: Installation • Applying Power for
- Page 63 and 64: Installation • Configuring for Ne
- Page 65 and 66: Operation • Operator Functions
- Page 67 and 68: Operation • Operator Functions
- Page 69 and 70: Operation • Operator Functions
- Page 71 and 72: Operation • Operator Functions
- Page 73 and 74: Operation • Operator Functions
- Page 75 and 76: Operation • Operator Functions
- Page 77 and 78: Operation • Operator Functions
- Page 79 and 80: Operation • Operator Functions
- Page 81 and 82: Operation • Operator Functions
- Page 83 and 84: Operation • Operator Functions
- Page 85 and 86: Operation • Operator Functions
- Page 87 and 88: Operation • Supervisor Functions
- Page 89 and 90: Operation • Supervisor Functions
- Page 91 and 92: Operation • Supervisor Functions
- Page 93 and 94: Operation • Supervisor Functions
- Page 95 and 96: Operation • Supervisor Functions
- Page 97 and 98: Operation • Supervisor Functions
- Page 99 and 100: Operation • Supervisor Functions
- Page 101 and 102: Operation • Supervisor Functions
- Page 103 and 104: Operation • Supervisor Functions
- Page 105 and 106: Service information . . . •If you
Installation • Making the Necessary Connections •• Pneumatic Input RequirementsPower is applied to the internal systems of the <strong>RoadRunner</strong> when the powerswitch is ON. All power is removed when the power switch is OFF.2!WARNINGElectrical shock hazard. If the main power switch isON, power is applied to the electronic systems of<strong>RoadRunner</strong>, regardless of the position of the Emergency-Stopbutton or safety shield. Always turn the mainpower switch OFF before working inside the machine.Pneumatic Input Requirements<strong>RoadRunner</strong> requires a pressurized air source connected to the<strong>RoadRunner</strong>’s end panel. <strong>RoadRunner</strong> requires clean, dry, oil-free air, atapproximately 5.17 Bars (517 kPa) (75 psi) from an industrial grade compressor.The compressor tank should be of sufficient volume to maintainconstant air pressure at a minimum of 113 Liters/minute (4 cubic feet/minute).A 10 micron filter/separator/regulator must be installed betweenthe compressor and the <strong>RoadRunner</strong> to extract any contaminants andmoisture before the air enters the machine.Pneumatic Regulator KitProper operation of <strong>RoadRunner</strong> on SMT machines is accomplished byinstalling a <strong>Data</strong> I/O Regulator Kit. The kit ensures consistent air pressureand is required for proper <strong>RoadRunner</strong> operation.Check with <strong>Data</strong> I/O for your kit availability and installation instructions.The Regulator Kit Model Name (for ordering) for Assembleon Fuji, Panasonic,and Universal is RR-REGULATOR KIT-UF.Figure 2-30—Regulator Kit for Placement Machines(Instructions for <strong>RoadRunner</strong>/Siemens are listed below.)2—26 <strong>Data</strong> I/O • ProLINE-<strong>RoadRunner</strong> Owner’s <strong>Manual</strong> • 096-0240 [updated Mar2010]