2.5.6 Image Enhancement<br />

2.5.6.1 Electronic Methods<br />

Some advantages can be gained by using electronic enhancement systems<br />

to improve the contrast and resolution at the edge <strong>of</strong> a specimen or internal<br />

feature. An iterative process is usually required. However, care must be taken<br />

to ensure that the results so obtained are meaningful by making frequent<br />

reference to image quality indicators or the dimensions <strong>of</strong> reference features<br />

within the radiograph.<br />

2.5.6.2 Optical Methods Improvements can be made by magnifing the image<br />

by optical projection. A magnification <strong>of</strong> up to 10x is recommended.<br />