<strong>SMIQ</strong>SOURce:PHASe Subsystem3.5.14.18 SOURce:PHASe SubsystemCommand Parameter DefaultUnitRemark[:SOURce]:PHASe[:ADJust]:REFerence-360 deg to +360 deg radNo query[:SOURce]:PHASe[:ADJust] -360 deg to +360 degThe command indicates the phase between output signal and reference oscillator signal. Thissetting is only accepted using SOURce:PHASe:REFerence (cf. below). An indication in RADianis possible.Example: :SOUR:PHAS:ADJ 2DEG:SOUR:PHAS:ADJ 0.1RAD*RST value is 0.0 DEG[:SOURce]:PHASe:REFerenceThe command accepts the phase set using SOURce:PHASe:ADJust as a new reference phase.The command has no *RST value.Example: :SOUR:PHAS:REF1125.5555.03 3.133 E-9