<strong>HX8218</strong>-<strong>C01</strong>960CH TFT LCD Source Driver with TCON5.8 Power ON/OFF sequenceDATA SHEET V04To prevent the device damage from latch up, the power ON/OFF sequence shownbelow must be followed.Power ON: VCC, GND VDD, VSS V1 to V8Power OFF: V1 to V8 VDD, VSS VCC, GND5.9 Power ON Control<strong>HX8218</strong>-<strong>C01</strong> has a power ON sequence control function. There are two kinds of themode. One is Auto mode, and another is Manual Mode.Auto Mode: When power is ON, black data is outputted for 20-frames (default value)first, from the falling edge of the following Vsync signal.It can be defined in Register R3 A_TIME1(bit5) and A_TIME0(bit4) whenAUTO_DP(bit7) = ”H”Figure 5. 5 Power on control for Auto ModeManual Mode: When power is ON, you should set the Register R3 AUTO_DP(bit7)= ”L” to stay at the manual mode. Black data is outputted until the DISP_ON(bit 6) = Hthen display the normal image.Figure 5. 6 Power on control for Manual ModeHimax ConfidentialThis information contained herein is the exclusive property of Himax and shall not be distributed, reproduced, or disclosedin whole or in part without prior written permission of Himax. Subject to change without notice.-P.20-October 2006