16.07.2015 Views

KMWEEP-EA Final Report June 3 2008.pdf - kuidfc

KMWEEP-EA Final Report June 3 2008.pdf - kuidfc

KMWEEP-EA Final Report June 3 2008.pdf - kuidfc

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

KARNATAKA MUNICIPAL WATER PUMPING IMPROVEMENTS IN SIX TOWNSENVIRONMENTAL AUDIT AND PREPARING ENVIRONMENTAL MANAGEMENT PLANFINAL REPORTTable B-4: Summary of ImpactsImpactsMitigation MeasuresLocationNone potentiallysignificantTechnical recommendationNone potentiallysignificantImplementations/ ConstructionNone potentiallysignificantOperation and MaintenanceNoise and vibrationsleading to nuisances toworkers andneighboursGeneration of wasteand disposalHazards tohealth/safety ofworkmenProviding noise Personal ProtectiveEquipment (PPE) such as earmuffs toworkersResponsibilityPreliminary CostingN/a N/a N/aN/a N/a N/aN/a N/a N/aTwo rows of Tree planting/vegetation onthe periphery of the pumping stationsNoise measurements should be conductedRegular Health checkups for workersDifferent types of waste should besegregated and stored in differentcontainers to enhance reuse or recyclingof materials and their proper disposalRecords of wastes for type, amount ofwastes generated, recycled and disposedStorage and disposal of waste at predesignatedand approved location orwaste recycle dealers.Inclusion of Occupational Safety Plan inO&M guidelinesOccupational Safety Plan for workforcewhich will include:1. Protection against physical, electricaland fire hazards2. Adequate personal safety precautionmeasures like wearing of gloves, helmets,earplugs, safety shoes etc.,3.Training for workers on handlingpotential site emergencies, dangers,including potential health effectsMunicipalCorporation /KUWSDB/ O&MAgencyMunicipalCorporation/KUWSDB/ O&MAgencyMunicipalCorporation/KUWSDB/ O&MAgencyINR 2500/- for each PPE(earmuff)Minimum 4 (considering 4personnel in each shift ) foreach pumping stationINR 150/- per Sqm of vegetation(Appox. 100 Sqm or landavailable along the boundarywall at each pumping station)Annual maintenance INR10,000/- at each pumping stationNoise Monitoring At pumpingstation (INR 2500/-each location)Minimum two locations at eachpumping StationHealth check-up cost peroperator level employee INR1000/-per annum.(Considering10 employees per pumpingstation)No cost ImplicationsNo cost ImplicationsFire fighting equipments like fieextinguishers @ INR 3000/Unit(minimum 4 for each pumpingstation)Each set of personal safetyprecaution equipments INR2500/-(Minimum 4sets –considering 4 personnel in eachshift for each pumping station)First aid equipments andaccessories INR 2500/-OHS Training cost of INR10,000/- per session of 10workers annuallyThe cost of implementing above mitigation measures as capital costs for equipments works out toINR 2.0 lakhs (INR 0.50 lakhs for each pumping station).The training and maintenance is35 World Bank

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!