INSTRUCTION MANUAL<strong>TMS2000</strong>WIRE SPLICE AND SEAL INSTRUCTIONS - 2 CONDUCTOR PAIRS KIT 10585-2LWARNING: USE CONNECTORS ONLY FOR THEIR DESIGNATED PURPOSE. DO NOT USE FOR AC WIRING.1BREAK APART 2 STRIP WIRESFIELD CABLE *(2) "V" SLOTS1.25".75"OUTERSLEEVEUSE TO SEAL MP45xPROBE CABLE SPLICESINNERSLEEVEMP45x PROBECABLE* PROBE FIELD CABLE SHIELD WIRE HAS NO CONNECTION1.25".75"SPLICE SEAL WIRE CONNECTOR PROVIDED BY PNEUMERCATOR34STRIP GREEN WIRE AS NEEDED TOCONNECT TO JUNCTION BOX GROUND STUDGREENGROUND WIREBEND OVERGROUND WIREAS SHOWN5TWIST WIRES (EXCEPT FOR GND WIRE)6INSERTSNAP ON OUTER SLEEVEDO NOT REUSEPULL ONE TWISTED LEAD PAIRTHROUGH EACH "V" AND BEND OVERCONNECT GND WIRETO JUNCTION BOXGND STUDPNEUMERCATORBulletin 181 Rev. B (02/09/05)Liquid Level Control SystemsPage 1 of 12/9/2005 6:02:06 PM, 1:1, © COPYRIGHT 2005 PNEUMERCATOR COMPANY, INC.Figure 3-5 - MP45xS Splice Kit Instructions<strong>TMS2000</strong> Installation.doc 07-11-05PAGE 28