16.07.2015 Views

TMS2000 - OEC Fluid Handling, Inc.

TMS2000 - OEC Fluid Handling, Inc.

TMS2000 - OEC Fluid Handling, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INSTRUCTION MANUAL<strong>TMS2000</strong>SECTION 2 – INSTALLATION DETAILS2.1 INSTALLATION CHECKLISTWARNINGDo NOT apply power to the <strong>TMS2000</strong> until its installation has been checked andfound to be in accordance with these instructions; National Electric Code;Federal, State and Local codes; and other applicable safety codes. FAILURE TOCOMPLY MAY RESULT IN PERSONAL INJURY, PROPERTY LOSS ANDEQUIPMENT DAMAGE.The following points should be reviewed in preparation for installation, and again when installationis complete.1. Review Figure 3-1 to ensure that all of the safety/wiring requirements have been met.2. Check that all equipment at job site matches the DESIGN DRAWING SPECIFICATIONS for thetank sizes and control features required.3. The console should be located as close as possible to the demarcation point of the hazardousarea. Never mount inside the hazardous area.4. POWER to the console should be properly wired to a DEDICATED 120/240 VAC CIRCUITBREAKER. No other equipment can be powered from the same circuit breaker as the TMS.5. System cannot be connected to equipment that uses or generates more than 250 volts withrespect to earth.6. All TMS grounds must be terminated at the GND BUSS BAR in the same service panel as TMSpower. A grounding rod, coldwater pipe or other connection should not be used. Refer to Figure3-3 for illustrated details.7. The magnetostrictive probe inputs and the sensor inputs are two different intrinsically safecircuits and must be installed in separate cables or in one cable which has suitable insulation.Refer to NEC Article 504-30 (b) or CEC Appendix F6.3 for additional information.8. Do not drill or modify enclosure. Use only knockouts provided. Failure to comply will voidwarranty and may present a safety hazard.9. I.S. cabling should be selected from the Cable Selection Chart in Figure 3-2. Each probe orsensor wire/cable run SHOULD NOT EXCEED THE MAXIMUM DISTANCE RATING ON THECABLE SELECTION CHART. Color-coding or numbering is highly recommended.10. WATERPROOFING FIELD WIRE SPLICES using factory supplied splice kits is required forproper system operation.<strong>TMS2000</strong> Installation.doc 07-11-05PAGE 8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!