QUICKGUIDE TOSYSTEM 2ACCESS CONTROLINSTALLATION<strong>access</strong> <strong>control</strong><strong>system</strong>s


1 2 34 5 67 8 90 #1 2 34 5 67 8 90 #QUICKGUIDE TO ACCESS CONTROL INSTALLATION<strong>access</strong> <strong>control</strong><strong>system</strong>sSystem 2 - Model 2016One Door Control with Anti-PassbackModel 2016E16.5VAC40VAABA B C DPOWERSUPPLYCONTACTMAG LOCK**IN Keypadand/orIN Card ReaderOUT Keypadand/orOUT Card Reader<strong>Corby</strong> Card<strong>Corby</strong> CardPART NUMBERS AND WIRE SPECIFICATIONS(Part Numbers) are for WireSignalBOLD = Outdoor VersionDESCRIPTION WIRE TYPE PART #ACard Reader: Choose from Bar Code, Data Chip*, Magnetic Stripe, Proximityand 30 bit Wiegand. All readers have the necessary LEDs for visualfeedback. Only one card technology can be used at a time.Supports 26 and 30-bit Wiegand card formats.5 conduc<strong>to</strong>r, 22 gauge, shielded - 500 feet maximum. (67005)The wire length can be increased using an extender module.Bar Code: 4150Mag Stripe: 4073, 4075Wiegand: , , 404240444046Prox: , 4173-41744175-4176BKeypad: Choose from any one of seven indoor or outdoor keypads w/ LEDs.8 conduc<strong>to</strong>r, 22 gauge, shielded - 1000 feet maximum. (67007)4010, , 4014, 40124062 ,4063, , 40644066CMagnetic Door Lock or Door Strike2 conduc<strong>to</strong>r, 22 gauge, shielded - 1000 feet maximum. (95211)4252 Magnetic Lock4253 Door StrikeDMagnetic Contact: Use for Door Ajar / Forced Entry.A second contact can be used for zone moni<strong>to</strong>ring.2 conduc<strong>to</strong>r, 22 gauge, shielded - 1000 feet maximum. (95211)4255ETransformer: Supplied with the System 2. 16.5VAC 40VA2 conduc<strong>to</strong>r, 18 gauge, non-shileded. (93302)SUPPLIEDData Chip readers require a different conduc<strong>to</strong>r wire.5 conduc<strong>to</strong>r, 22 gauge, shielded - 100 feet maximum.4302-4307For further assistance, call (800) OK CORBY


1 2 34 5 67 8 90 #PUSH TO EXIT1 2 34 5 67 8 90 #PUSH TO EXITQUICKGUIDE TO ACCESS CONTROL INSTALLATION<strong>access</strong> <strong>control</strong><strong>system</strong>sSystem 2 - Model 2016Two Door ControlModel 2016EA B C DPOWERSUPPLY16.5VAC40VAA B C DPOWERSUPPLYCONTACTCONTACTMAG LOCKMAG LOCKDOOR 1DOOR 2**OUT RTEOUT RTEIN Keypadand/orIN Card ReaderIN Keypadand/orIN Card Reader<strong>Corby</strong> Card<strong>Corby</strong> CardIf using a door strike <strong>to</strong> secure the door, a Request-To-Exit but<strong>to</strong>n may not be necessary.PART NUMBERS AND WIRE SPECIFICATIONS(Part Numbers) are for WireSignalBOLD = Outdoor VersionDESCRIPTION WIRE TYPE PART #ACard Reader: Choose from Bar Code, Data Chip*, Magnetic Stripe, Proximityand 30 bit Wiegand. All readers have the necessary LEDs for visualfeedback. Only one card technology can be used at a time.Supports 26 and 30-bit Wiegand card formats.5 conduc<strong>to</strong>r, 22 gauge, shielded - 500 feet maximum. (67005)The wire length can be increased using an extender module.Bar Code: 4150Mag Stripe: 4073, 4075Wiegand: , , 404240444046Prox: , 4173-41744175-4176BKeypad: Choose from any one of seven indoor or outdoor keypads w/ LEDs.8 conduc<strong>to</strong>r, 22 gauge, shielded - 1000 feet maximum. (67007)4010, , 4014, 40124062 ,4063, , 40644066CRequest-To-Exit But<strong>to</strong>n: Choose from a heavy-duty or light duty version.The RTE But<strong>to</strong>n would be located on the opposite side of the door (interior).6 conduc<strong>to</strong>r, 22 gauge, shielded - 1000 feet maximum.4035 Heavy-Duty4135 Light- DutyDMagnetic Contact: Use for Door Ajar / Forced Entry.A second contact can be used for zone moni<strong>to</strong>ring.2 conduc<strong>to</strong>r, 22 gauge, shielded - 1000 feet maximum. (95211)4255ETransformer: Supplied with the System 2. 16.5VAC 40VA2 conduc<strong>to</strong>r, 18 gauge, non-shileded. (93302)SUPPLIEDData Chip readers require a different conduc<strong>to</strong>r wire.5 conduc<strong>to</strong>r, 22 gauge, shielded - 100 feet maximum.4302-4307For further assistance, call (800) OK CORBY


QUICKGUIDE TO ACCESS CONTROL INSTALLATION<strong>access</strong> <strong>control</strong><strong>system</strong>sSystem 2 - Model 2016Communication with a PCOn-Site CommunicationsModel 2016 Model 2016 Model 2016CAOPTIONAL LOCAL PARALLELPRINTER (CENTRONICS STYLE)CONNECT ONLY TO YOUR PCYOUR PC WITH STANDARD TERMINALEMULATOR SOFTWARE. CAPABLE OFVT-100 EMULATION.BBTO MORE 2016’sMaximum of 8 <strong>control</strong> panels (16 doors)Remote Communications1200 - 9600BAUD MODEMACYOUR PC WITH STANDARD TERMINALEMULATOR SOFTWARE. CAPABLE OFVT-100 EMULATION.OPTIONAL LOCAL PARALLELPRINTER (CENTRONICS STYLE)CONNECT ONLY TO YOUR PCA1200 - 9600BAUD MODEMModel 2016 Model 2016Model 2016BBTO MORE 2016’sMaximum of 8 <strong>control</strong> panels (16 doors)PART NUMBERS AND WIRE SPECIFICATIONS(Part Numbers) are for WireSignalDESCRIPTION WIRE TYPE PART #APC or Modem: PC runs using standard terminal emulation software. 5 conduc<strong>to</strong>r, 22 gauge, shielded - 100 feet maximum. (67005)4412 PC4100 Video Display TerminalBRS485: Communications loop for multiple System 2’s. Eight <strong>to</strong>tal (16 doors).2 conduc<strong>to</strong>r, 22 gauge, shielded, twisted pair.4000 feet maximum from first unit <strong>to</strong> last unit. (93302)4126CPrinter: Parallel (connects <strong>to</strong> PC). Serial (connects directly <strong>to</strong> panel). Standard parallel printer cable. N/AFor further assistance, call (800) OK CORBY


QUICKGUIDE TO ACCESS CONTROL INSTALLATION<strong>access</strong> <strong>control</strong><strong>system</strong>sEquipment ChecklistSYSTEM 2 PANELS2003Supports 1 Door, 280 Users with names - 485 withoutnames maximum, 256 Time/Holiday Cells, Full DuplexRS232, Generic 26-bit Wiegand Card Capability,Auxiliary Relay #1 and Voltage Output #1, ForcedEntry, & Door Ajar Inputs, Emergency Drop Input,Request-To-Exit Input, and One Zone Input. Includesheavy-duty steel Cabinet, 48 Character LCD,16.5 VAC Transformer, 12 V 4AH stand-by battery,Installation manualWiegand Readers (4060 mounting hardware kit recommended)4042Indoor/Outdoor swipe (beige)4044Indoor/Outdoor swipe (black)4046Indoor/Outdoor Insertion reader (black)(4052 mounting b racket recommended)Wiegand Cards4047Plain white, Pho<strong>to</strong> ID4048<strong>Corby</strong> logo Pho<strong>to</strong> ID4049Standard 30 bit card2016Same as 2003 but adds: Second Door, Anti-Passback,Temporary Users, One Zone Input, Auxiliary Relay #2,^One Voltage Output, Large RAM, RS485, eight (8)additional Time Schedules and code and schedulelinkage <strong>to</strong> auxiliary outputs.^Large RAM supports additional users.2020Upgrade Kit for P/N 2003: Adds Second Door,Anti-Passback, Temporary Users, One Zone Input,Auxiliary Relay #2, One Voltage Output, Large RAM,RS485, eight (8) additional Time Schedules and codeand schedule linkage <strong>to</strong> auxiliary outputs.OPTIONAL PROGRAMMING DEVICE4100Video Display TerminalKEYPADSIndoor4010Single-gang, flush mount with one green LED4014Hidden View with tamper switch, One Green and RedLED, Single-gang, surface mount4063Heavy-Duty, flush mount w/ one Green & Red LEDOutdoor4012Aluminum cover, surface mount w/ one Green & RedLED. Also includes 12VDC night light4062Cast metal Heavy-Duty mounted in a Lock-box and ona goose neck. Includes one Green and Red LED4064Cast metal Heavy-Duty mounted in a Lock-box.Includes one Green and Red LED4066Cast metal, flush mount, Heavy-Duty with one Greenand Red LEDREADERSData Chip Readers4302Single-gang, flush mount, with one Green LED4303Single-gang, flush mount, with one Green & Red LED4304Narrow, flush mount with one Green LED430 5Narrow, flush mount with one Green and Red LED4306Reader Head and one Green LED4307Narrow, (black) surface mount with bi-color LED,back-lit read head and mounting hardwareData Chips4320Chip assembled on a key-ring with <strong>Corby</strong> logo4321Chip Only - For use with badges, pho<strong>to</strong> ID cards etc.4323Roll of double stick tape (dots) for adhering Data Chip -100 pieces per roll (required for 4321)HID Proximity Readers4173Indoor/Outdoor, 10" - 27" read range4174Indoor/Outdoor, 1" - 9" read range4175Indoor/Outdoor, thinline 2" - 4" read range4176Indoor/Outdoor, mullion 2" - 5" read rangeHID Proximity Cards4170Keyfob, 26 bit4171Credit card size w/ badge slot, 26 bit4172Credit card size, graphics quality for pho<strong>to</strong> ID, 26 bitMagnetic Stripe Readers4073Indoor, surface mount, swipe (black)4075Indoor/Outdoor, surface mount, swipe, (beige)Magnetic Stripe Cards4074Credit card size, for use with 4073, 4075 readersBar Code Readers4150Indoor/Outdoor, surface mount, swipe, (black)Bar Code Cards4151Credit card sizeMODEMS4118Short haul up <strong>to</strong> 1 mile.4126Phone modem. Connect One at the circuit boardlocation and one <strong>to</strong> the VDT or PC12 VDC DOOR LOCKS (Require 4094 Power Supply)4252Magnetic Lock for doors that swing out.4253Door strike for metal or wood door framesEXIT DEVICES4035Heavy-duty exit but<strong>to</strong>n (LED illuminated)4135Light-duty exit but<strong>to</strong>nPOWER SUPPLIES40946-12 Volt with 6A lead acid battery and transformerMISCELLANEOUS2018Data Chip Programming Wand for faster and easierprogramming of Data Chips4056Line Extender Module. Increases distance 500 feet.4255Magnetic Door ContactFor further assistance, call (800) OK CORBY


QUICKGUIDE TO ACCESS CONTROL INSTALLATION<strong>access</strong> <strong>control</strong><strong>system</strong>sArchitectural SpecificationsSystem 2 - Model 2003The <strong>access</strong> <strong>control</strong> <strong>system</strong> will be a <strong>Corby</strong> Model 2003 “System 2" or approved equal. System will <strong>control</strong> one door. System will be housedin a metal cabinet measuring 15.5" x 11" x 4.5". Cabinet will have a hinged door with a lock <strong>to</strong> prevent unauthorized <strong>access</strong> <strong>to</strong> the wiring.Memory allocation for users, event s<strong>to</strong>rage and mode of operation will be user adjustable. System will support 527 maximum users and beprogrammable from a built-in keypad and 48 character LCD display. System will provide anRS-232 interface for optional programmingthrough a video display terminal, PC or the connection of a printer.System will provide built-in charging for an external lead acid battery <strong>to</strong> support full <strong>system</strong> operation upon loss of main AC power. Each twodoorunit will contain a lithium battery for backup of user, <strong>system</strong> and event data upon loss of main AC power and main battery backup.System supports a perpetual clock and calendar <strong>system</strong>, accurate <strong>to</strong> the year 2086.Eight time schedules will be provided for the <strong>control</strong> of users, doors and auxiliary functions. Each time schedule will consist of 32 cells eachfor a <strong>to</strong>tal of 256 time cells. Auxiliary relay outputs will be triggerable from twenty different <strong>system</strong> events.System will contain two direct inputs for each of the following: Keypad, Wiegand (including swipe, insert and Proximity), Bar code, MagneticStripe and Touch Memory readers, Door Ajar/Forced Entry, Request-To-Exit and Zone. An input will be provided for an emergency drthe main door relays. The <strong>system</strong> will accept BCD encoded keypad codes, a proprietary <strong>Corby</strong> 30 bit Wiegand code, generic 26code, Code-39 bar code, track-two magstripe code and Dallas Touch Memory device codes. System will provide 5 VDC @ 125ma. And 12VDC @ 250ma. for card readers. Resettable fuses will provide protection for five and 12 volt outputs, AC power and rechargeable battery.op ofbit WiegandSystem will contain two of the following outputs: Door relay consisting of form A and form C contacts rated 5 amps @ 30 VDC, Red andGreen LED indica<strong>to</strong>r. The following additional outputs will be provided for signaling, shunt and schedule <strong>control</strong>: Two form C relays rated fiveamps, 30VDC, and two voltage outputs rated -50 mA.SYSTEM 2 - Model 2016The <strong>access</strong> <strong>control</strong> <strong>system</strong> will be a <strong>Corby</strong> Model 2016 “System 2" or approved equal. System will <strong>control</strong> two doors. System will behoused in a metal cabinet measuring 15.5" x 11" x 4.5". Cabinet will have a hinged door with a lock <strong>to</strong> prevent unauthorized <strong>access</strong> <strong>to</strong> thewiring. Mem ory allocation for users, event s<strong>to</strong>rage and mode of operation will be adjustable. System will be programmable from a built-inkeypad and 48 character LCD display. System will provide an RS-232 interface for optional programming through a video display terminal,PC or the connection of a printer. System will provide an RS-485, two wire interface for connection <strong>to</strong> other System 2's in a network. Amaximum of eight <strong>system</strong>s will be networkable <strong>to</strong> provide <strong>control</strong> for 16 doors.System will provide b uilt-in charging for a lead acid battery <strong>to</strong> support full <strong>system</strong> operation upon loss of main AC power. System will containa lithium battery for backup of user, <strong>system</strong> and event data upon loss of main AC power and main battery backup. System will support aperpetual clock and calendar <strong>system</strong>, accurate <strong>to</strong> the year 2086.System will support 6000 users in two door, standalone mode and 4000 users in network mode. 16 time schedules will be provided for the<strong>control</strong> of users, doors and auxiliary func tions. Each time schedule will consist of 64 cells each for a <strong>to</strong>tal of 1024 time cells. System willallow hard and soft antipassback. Auxiliary relay outputs will be triggerable from twenty different <strong>system</strong> events.System will contain two direct wire inputs for each of the following: Keypad, Wiegand (including swipe, insert and Proximity), Bar code,Magnetic Stripe and Touch Memory readers, Door Ajar/Forced Entry, Request-To-Exit and Zone. An input will be provided for an emergencydrop of t he main door relays. The <strong>system</strong> will accept BCD encoded keypad codes, 26 bit standard Wiegand codes, a proprietary <strong>Corby</strong> 30bit Wiegand code, 26a Code-39 bit Wiegand bar codes, code, track-two magstripe codes and Dallas Touch Memory device codes. Systemwill provide 5 VDC @ 125 ma. and 12 VDC @ 250 ma. for card readers. Resettable fuses will provide protection for 5 and 12 volt outputs, ACpower and rechargeable battery.<strong>access</strong> <strong>control</strong><strong>system</strong>s<strong>Corby</strong> <strong>Industries</strong>, Inc.1501 E. Pennsylvania StreetAllen<strong>to</strong>wn, PA 18103Phone: (610) 433-1412 Toll Free: (800) 652-6729Fax: (610) 435-1963 http://www.corby.comP/N F9921 June 18, 1998 k:\corel\instruct\quickgde.cdr