13.07.2015 Views

A.O.Smith Motor Catalog - Universal Electric Motors

A.O.Smith Motor Catalog - Universal Electric Motors

A.O.Smith Motor Catalog - Universal Electric Motors

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

NEMA C-Face 3-Phase Pump <strong>Motor</strong>sFeatures:• Ball Bearings • Continuous Duty • Internal Junction Box• Keyed and Stainless Steel Threaded Shafts • NEMA “56C” Mount• Open Dripproof • 40°C Ambient • 60 HzT3052NEMA C Face mounting bracket, and end frames are die-cast corrosion resistant aluminum, accurately machined for maximumconcentricity, and minimum runout. Stator assemblies are press fitted into rolled steel main frames. Double shielded ball bearings, selected forquiet operation, are lubricated for life with greases specifically chosen for moisture and heat resistant qualities.1/2” x 14 thread tapped opening is provided for conduit fitting. No external junction box required connections made under motor canopy. <strong>Motor</strong>sare supplied with horizontal canopy but are easily converted for vertical operation with the use of optional vertical canopy (call Customer Servicefor more information).Max. Service Stock Approx.HP RPM Volts Amps Factor Frame Number Shaft Protector “AG” Notes1/2 3450 208-230/460 2.7/1.35 1.6 56J T3052 Thrd None 8-5/83/4 3450 208-230/460 3.4/1.7 1.5 56C K3072 Key None 9-1/8208-230/460 3.4/1.7 1.5 56J T3072 Thrd None 9-1/81 3450 208-230/460 4.0/2.0 1.4 56C K3102 Key None 9-11/16208-230/460 4.0/2.0 1.4 56J T3102 Thrd None 9-11/161-1/2 3450 208-230/460 6.8/3.4 1.3 56C K3152 Key None 11-5/16208-230/460 6.8/3.4 1.3 56J T3152 Thrd None 11-5/162 3450 208-230/460 8.6/4.3 1.2 56C K3202 Key None 11-5/16208-230/460 8.6/4.3 1.2 56J T3202 Thrd None 11-5/16Important:1. Total output (HP x service factor) of replacement motormust equal or exceed motor being replaced.2. The pool motors on this page are NOT equipped with aSafety Vacuum Release System (SVRS). SVRS helpsprevent drowning due to body entrapment on underwaterdrains. In some pool configurations, if a person’s bodycovers the drain, the person can be trapped by suction.The SVRS turns off the pump if this occurs.Depending on your pool configuration,a SVRS may be required to meet local, state, and federalrequirements.212 www.aosmithmotors.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!