Appendix FHydraulic System TargetCleanliness LevelsWhere a hydraulic system user has been able to check cleanliness levels overa considerable period, the acceptability, or otherwise, of those levels can beverified. Thus if no failures have occurred, the average level measured maywell be one which could be made a bench mark. However, such a level mayhave to be modified if the conditions change, or if specific contaminant-sensitivecomponents are added to the system. The demand for greater reliabilitymay also necessitate an improved cleanliness level.The level of acceptability depends on three features:• the contamination sensitivity of the components• the operational conditions of the system• the required reliability and life expectancyHydraulic System Target Cleanliness Levels 71