15.3 Active Flow ControlThis is only needed for High Pressure, Off-Line Operation.Figure 15.5<strong>CMS</strong> flow actively regulated.A pressure compensated flow control valve is fitted to the <strong>CMS</strong> drainoutlet. This maintains a constant flow rate even with a varying inletpressure (provided this pressure stays above a minimum workingvalue). A suitable valve is the <strong>CMS</strong>-FC1 (see 2.1.2), but other onescan be used too.54 Hydraulic Connection