large particles in the system. When selected, two successive "clean’’results are needed before testing halts.12.7 AlarmsThe <strong>CMS</strong> has two switched "alarm’’ outputs that can be used to signalexternal equipment in various ways, according to the test resultsand the alarm settings. There is also a multi- colour front panel lightwhich indicates how the result compares to the set alarm thresholds.The alarm settings are comprehensive and flexible, allowing the<strong>CMS</strong> to be used in many different scenarios.12.7.1 Alarm LEDThe front panel LED also indicates these alarm states to the operator(see section 4).12.7.2 Alarm LevelsThe various alarm thresholds are set in the Contamination Code Target/ Alarm Levels area of the dialogue.Figure 12.2ISO4406:1999 Alarm LevelsAlarms can be set on combinations of cleanliness codes, water contentand temperature. The available codes, and their interpretation,34 Settings