Compact Filters HXLHigh Capacity, High Efficiency Barrier for Rotating MachinerySpecification:Maximum operating temperature 70 °CMediaCell sides and headerSeparatorsFaceguardsGasketHigh efficiency, water resistant glass fibrePolystyrene and ABSHot meltPlastic faceguards on air leaving sideGasket on air leaving side as standardTechnical Data:Type C6MAA C7MAA C8MAA C9MAA C10MAANorminal cell size (inch) 24x24x17 24x24x17 24x24x17 24x24x17 24x24x17Actual size (mm) 592x592x440 592x592x440 592x592x440 592x592x440 592x592x440Initial resistance Pa in WG Pa in WG Pa in WG Pa in WG Pa in WGat 5100 m³/h 3000 CFM 110 0.44 115 0.46 120 0.48 145 0.58 190 0.76at 4250 m³/h 2500 CFM 80 0.32 91 0.36 100 0.40 115 0.46 145 0.58at 3400 m³/h 3400 CFM 55 0.22 70 0.28 75 0.30 80 0.32 110 0.44Final Resistance²) 635 2.5 635 2.5 635 2.5 635 2.5 635 2.5Burst pressure 7600 30 7600 30 7600 30 7600 30 7600 30Media area m²/ft² 28.1 / 302 28.1 / 302 28.1 / 302 28.1 / 302 28.1 / 302Filter class EN779 /EN1822¹)M6 F7 F8 F9 H10Average efficiency EN779 60-65 80-90 90-95 >95 >99Average arrestanceOn AC Fine test Dust (%)100 100 100 100 100Filter class ASHRAE 52.2¹) MERV13 MERV14 MERV15 MERV16 MERV16Notes¹) All performance data based on EN779 / EN1822 and ASHRAE 52.2²) Recommended maximum value. Filters can be operated to a lower or higher final resistance without materially affecting filter efficiency³) Standard Compact Filter HXL filters have 25 mm header; suffix “A” denotes 20mm header as option19

Cassette Filters VXL HEPAHigh Efficiency Barrier for Rotating MachineryApplications• Classification H10, H11, H12, and H13 to EN1822• Long life service• High media area; low pressure drop• Lightweight and easy to install• Full polymer construction• Fully incinerable; free of halogensClassification acc. to EN1822• Filter class H10 – H1320

Compact Filters HXLHigh Capacity, High Efficiency Barrier for Rotating MachinerySpecification:Maximum operating temperature 70 °CMediaCell sides and headerSeparatorsFaceguardsGasketHigh efficiency, water resistant glass fibrePolystyrene and ABSHot meltPlastic faceguards on air leaving sideGasket on air leaving side as standardTechnical Data:Type C6MAA C7MAA C8MAA C9MAA C10MAANorminal cell size (inch) 24x24x17 24x24x17 24x24x17 24x24x17 24x24x17Actual size (mm) 592x592x440 592x592x440 592x592x440 592x592x440 592x592x440Initial resistance Pa in WG Pa in WG Pa in WG Pa in WG Pa in WGat 5100 m³/h 3000 CFM 110 0.44 115 0.46 120 0.48 145 0.58 190 0.76at 4250 m³/h 2500 CFM 80 0.32 91 0.36 100 0.40 115 0.46 145 0.58at 3400 m³/h 3400 CFM 55 0.22 70 0.28 75 0.30 80 0.32 110 0.44Final Resistance²) 635 2.5 635 2.5 635 2.5 635 2.5 635 2.5Burst pressure 7600 30 7600 30 7600 30 7600 30 7600 30Media area m²/ft² 28.1 / 302 28.1 / 302 28.1 / 302 28.1 / 302 28.1 / 302Filter class EN779 /EN1822¹)M6 F7 F8 F9 H10Average efficiency EN779 60-65 80-90 90-95 >95 >99Average arrestanceOn AC Fine test <strong>Dust</strong> (%)100 100 100 100 100Filter class ASHRAE 52.2¹) MERV13 MERV14 MERV15 MERV16 MERV16Notes¹) All performance data based on EN779 / EN1822 and ASHRAE 52.2²) Recommended maximum value. Filters can be operated to a lower or higher final resistance without materially affecting filter efficiency³) Standard Compact Filter HXL filters have 25 mm header; suffix “A” denotes 20mm header as option19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!