13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

W<strong>or</strong>k in the Vicinity <str<strong>on</strong>g>of</str<strong>on</strong>g> Electrical Apparatusmobile plant, precauti<strong>on</strong>s shall be taken to protectthe operat<strong>or</strong> from hazardous step and touchpotentials. No pers<strong>on</strong> other than the mobile plantoperat<strong>or</strong> shall touch the mobile plant whilst inoperati<strong>on</strong>.Where mobile plant e.g. EWP is <strong>on</strong>ly partiallyinsulated, the following permanent sign shall befixed at each operat<strong>or</strong>’s stati<strong>on</strong>:DANGER – BEWARE OF POWER LINESThis appliance is not fully insulated. Do notpermit any uninsulated part <str<strong>on</strong>g>of</str<strong>on</strong>g> this appliance tobe in close proximity to live c<strong>on</strong>duct<strong>or</strong>s.Insulated mobile plant shall be tested at specificintervals as per <strong>or</strong>ganisati<strong>on</strong>al procedures andmarked to show the date <str<strong>on</strong>g>of</str<strong>on</strong>g> the next routine test.5.5 WORK BY ORDINARY PERSONSWhere <strong>or</strong>dinary pers<strong>on</strong>s are required to <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> in thevicinity <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus, the <strong>or</strong>dinary pers<strong>on</strong>per<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>ming the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>, the pers<strong>on</strong> in charge <str<strong>on</strong>g>of</str<strong>on</strong>g> the<str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> and the pers<strong>on</strong> in charge <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>electrical</str<strong>on</strong>g>apparatus shall all cooperate to ensure that the<str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> is per<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>med safely, and that specificprecauti<strong>on</strong>s are taken.Blue Book – December 2005 Page 47 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!