13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

W<strong>or</strong>k in the Vicinity <str<strong>on</strong>g>of</str<strong>on</strong>g> Electrical Apparatus5.3 ERECTION OR DISMANTLING OFOVERHEAD CONDUCTORSWhen overhead lines (other than insulated low<strong>voltage</strong> service lines) are being erected,dismantled, <strong>or</strong> replaced and there is any possibility<str<strong>on</strong>g>of</str<strong>on</strong>g> c<strong>on</strong>tact with, <strong>or</strong> inducti<strong>on</strong> from, adjacent livec<strong>on</strong>duct<strong>or</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> any descripti<strong>on</strong>, such c<strong>on</strong>duct<strong>or</strong>sbeing moved shall be earthed by an approveddevice be<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>e <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> is commenced and shall remai<strong>near</strong>thed until the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> is completed. A c<strong>on</strong>duct<strong>or</strong>being so erected shall be earthed be<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>e it is liftedfrom the ground.C<strong>on</strong>siderati<strong>on</strong> shall be given to the use <str<strong>on</strong>g>of</str<strong>on</strong>g>appropriate restraining devices to c<strong>on</strong>trol suchc<strong>on</strong>duct<strong>or</strong>s when they are being moved.5.4 USE OF MOBILE PLANTMobile plant shall <strong>on</strong>ly be used in the vicinity <str<strong>on</strong>g>of</str<strong>on</strong>g> livec<strong>on</strong>duct<strong>or</strong>s and/<strong>or</strong> <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus afterprecauti<strong>on</strong>s appropriate to the particularcircumstances have been c<strong>on</strong>sidered and acti<strong>on</strong>taken to c<strong>on</strong>trol the associated hazards and risks.The c<strong>on</strong>trol measures to be c<strong>on</strong>sidered within a riskassessment should include:Blue Book – December 2005 Page 45 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!