<strong>Vogel</strong> Pumpen<strong>Vogel</strong> Pumpen<strong>Vogel</strong> - <strong>Submersible</strong> <strong>Pumps</strong>Design TVSizes 10“ to 12“1


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TVSizes:●●●101-105 TV, 10“ to 12“ wells121-123 TV, 12“ to 14“ wellsFor 8“ pump sizes refer to model TVS, List 3300.1.BPerformance Range:● Max. capacity 580 m 3 /h (2550 USgpm)● Max. head up 450 m (1480 feet)● Max. water temperature to 25 o C (77 o F)(Up to 60 o C - 150 o F upon request)●●Motor power up to 400 kW (540 HP)3 phase power supply 400 V, 50 Hz/460 V, 60 HzOther voltages or frequencies upon requestHandled liquid:●●Clear, non aggressive waterOptions for sea and thermal waterApplications:●●●●●●●<strong>Water</strong> supplyBooster systemsTurf and irrigationLowering of the ground water levelDraining and water level controlIndustrial cooling water supply,flush water systemsFire fighting, sprinkler systemsInstallation:●Vertical and horizontalwith or without check valveDesigned and developed in accordance with internationalstandards to fit customers requirements.2


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TVPeformance Range 50 HzFörderhöhe -Hauteur manométrique totale H [m]Total head H [feet]Förderstrom - Débit - Capacity Q [m 3 /h]Performance Range 60 HzFörderhöhe -Hauteur manométrique totale H [m]Total head H [feet]Förderstrom - Débit - Capacity Q [m 3 /h]3


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TV<strong>Submersible</strong> Motors Technology:VOGEL <strong>Submersible</strong> Motors in semi wet designFor this design the pre-filled motor space ishermetically seperated from the try winding.The winding itself is protected by resin.Design HF - 6“ <strong>Submersible</strong> Motors,Performance Range 4-45 kWDesign KF - 8“ <strong>Submersible</strong> Motors,Performance Range 30-150 kWDesign features:●Motor connection acc. NEMA standard.●Replaceable motor cable with water proof plugconnection.●Shaft sealing by mechanical seal and additionalsand protection on the shaft.●Radial bearing water lubricated slide bearingtype.●Motor space with water filling. The waterfilledmotor space is hermetically seperated from thestator with casing tube.●Winding cast resin embedded.●Thrust pad bearing design to take the axialforces of the pump rotor.●Rubber diaphragm to balance volume variationsof the motor liquid.Starting: Direct or star-delta, softstarter.Speed control via frequency inverters optional.5


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TV<strong>Submersible</strong> Motors Technology:VOGEL <strong>Submersible</strong> Motors in wet designMotor entirely filled with water.Motors with wet windings are rewindableDesign HFR, L6W - 6“ <strong>Submersible</strong> Motors,Performance Range 4-37 kWDesign KFR, L8W - 8“ <strong>Submersible</strong> Motors,Performance Range 37-92 kWDesign NFR, L10W - 10“ <strong>Submersible</strong> Motors,Performance Range 92-185 kWDesign L12W - 12“ <strong>Submersible</strong> Motors,Performance Range 185-300 kWDesign RP - 14“ <strong>Submersible</strong> Motors,Performance Range 280-400 kWDesign features:●6“ und 8“ motor connection (with motor shaft)according to NEMA standard.10“-14“ motor with shaft for keyed connection.●●●●●●●<strong>Water</strong>proof cable connection.Shaft sealing by double radial shaft seals,optional design with mechanical seal.Additional sand protection on the shaft.Radial bearing water lubricated slide bearingtype.Motor entirely filled with water.Winding specially isolated and renewable.Thrust pad bearing design to take the axialforces of the pump rotor.Rubber diaphragm to balance volumnevariations of the motor liquid.Starting: Direct or star-delta, soft starter.Speed control via frequency inverters optional.6


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TVMaterials:SizeVersionImpellersCasingWearringsStagecasingShaftBearingsleevesBearingbushes101-123NCast iron0.6025Cast iron0.6025_Cast iron0.60251 .4021 _ Rubber101-123SNBronzeCast iron0.6025_Cast iron0.60251 .4021 _ Rubber101-123SSBronzeBronze1.4462Bronze1 .4462_ RubberOther material combinations upon requestDesign features for long time performance:●●●●Heavy duty cast designShort bearing distances; low friction bearing designProoven motor technologyMaterial action dependent upon applicationDesigned for reliability and availability.Low maintainance.7


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TVApplications:Vertical installation in a well (borehole)pump directly arranged on discharge pipe.<strong>Pumps</strong> in horizontal filter well.Typical applications:●●●<strong>Water</strong> supplyIrrigation<strong>Water</strong> supplyin industryVertical installation in water reservoir(pump sump).Pump with cooling shroud assembled ondischarge pipe.Horizontal installation in water reservoir(pump sump).Pump with cooling shroud mounted onbrackets at basin bottom.Typical applications:●●●<strong>Water</strong> supplyIrrigation<strong>Water</strong> supply in industryTypical applications:●●●<strong>Water</strong> supplyIrrigation<strong>Water</strong> supply in industry8


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TVApplications:Vertical installation in pressure shroud asbooster pump in dry mounting.Horizontal installation in pressure shroudas booster pump in dry mounting.Typical applications:● <strong>Water</strong> supply ● Booster pumpingTypical applications:● <strong>Water</strong> supply ● Booster pumpingVertical installation in cavern.Horizontal installation in open sumps orbasins.Typical applications:●FountainsTypical applications:●Dewatering in mining9


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TVApplications with HYDROVAR:Hydrovar - pump control system that reduceslife cycle costs and improves reliability.Hydrovar for mounting on the wall – the solutionfor varying the speed of clear water submersiblepumps.By optimising the pump performance to match thesystem requirements, significant advantages aregained● Energy savings up to 50%● Low installation costs, since control valves, bypasspipework, switch and control panels canbe omitted● Soft start & stop to limit current peaks andprevent water hammers● Built in pump protection (dry run, overvoltage,undervoltage, overload, phase loss)● Fixed minimum speed to ensure the lubricationof the bearings● Adjustable switching frequency between2,5 and 8 kHz● Multi-pump management - up to 4 units can beconnected to one system● Patented pump control to stop the pump atzero demand immediately● Hydrovar units are available from 2,2 kW up to45 kW for mounting directly on the wall● Higher power ratings can be covered by usingthe HYDROVAR Smart controller in combinationwith any standard frequency converter -Hydrovar functionality without power limitation● Wide range of applications (water supply,irrigation, filter systems)Constant Pressure Constant Flow System Curve Actuator Mode10


<strong>Vogel</strong> PumpenVOGEL <strong>Submersible</strong> <strong>Pumps</strong>, Design TVApplications:Pump regulation according to pressure with automatic switch off at zero consumptionlevel (<strong>Vogel</strong> Patent).Constant pressurecontrolPressure control, along a systemcurve (automatic compensationof pipe losses)1 Pressure sensor2 Level switchApplication:Drinking water- and irrigation installations,where constant system pressure is requiredat highly fluctuating consumption.Advantages:Energy saving compared with throttlecontrols or bypass regulator in part loadoperation up to 70%.Constant flow control2 Level switch3 Flow sensor(metering orifice plate or IDM)Application:All filter system versions for constant filterloads, regardless to different pressure andcontamination levels.11Advantages:Prevention of excess flow rates andcavitation and energy savings comparedwith throttle controls up to 50%.


<strong>Vogel</strong> PumpenPumpenfabrik ERNST VOGEL GmbHA-2000 StockerauErnst <strong>Vogel</strong>-Straße 2Telefon: ..43-2266-604Telefax: ..43-2266-65311E-Mail: vogelpumpen.info@itt.comwww.vogel-pumpen.comLiability of manufacturer and/or supplierThe mentioned limits of operation and/or application are only ageneral information and may not be applied for every case. Thepermitted range of operation and/or application for the specific caseis to be obtained from our acknowledgement of order and/or theinstructions for installation, operation and maintenance, sent withthe goods.Liste 3200.1.B12/2007-e12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!