Use Scenario Receptor Level <strong>of</strong> Risk (with existingcontrols in place)Proposed Additional Contol- unrestricted entry into buildings treated at ratesabove 0.05 g a.i. / m 3 , up to 0.15 g a.i. / m 3 <strong>for</strong>o<strong>the</strong>r tasks is permitted after at least 120 hoursafter commencement <strong>of</strong> ventilation.Introduce minimum PPE/RPE requirements <strong>for</strong> entryinto treated buildings <strong>for</strong> ventilation tasks:RPE:- half-face respirator with minimum specification<strong>of</strong> A1P2;Introduce a maximum exposure time <strong>for</strong> entry intotreated area:- <strong>for</strong> ventilation tasks, < 30 minute/ day.Modified Level <strong>of</strong>Risk19 Operator exposure(mixing, loading,application)Non-negligible(> AOEL)Introduce maximum treated area <strong>of</strong> 3750 m 3 peroperator per day;Restrict number <strong>of</strong> cylinder changes to 1 per operatorper day.Negligible.Prescribe minimum levels <strong>of</strong> PPE/RPE:Connection / disconnection <strong>of</strong> cylindersPPE:- glovesRPE:- full-face respirator, with minimum specification<strong>of</strong> A1P2.Dichlorvos reassessment – application Page 93 <strong>of</strong> 436