13.07.2015 Views

Appendix D - BC Hydro - Transmission

Appendix D - BC Hydro - Transmission

Appendix D - BC Hydro - Transmission

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Article 5Article 5. . Interconnection Facilities Engineering, Procurement,Procurementsand Construction5.1 OptionsConstruction Timing. Unless otherwise mutually agreed to between the Parties,Interconnection Customer shall select the In-Service Date, Initial Synchronization Date,and Commercial Operation Date; and either Standard Option or Alternate Option set forthbelow for completion of <strong>Transmission</strong> Provider's Interconnection Facilities and NetworkUpgrades as set forth in <strong>Appendix</strong> A, Interconnection Facilities and Network Upgrades,and such dates and selected option. Such dates shall be set forth in <strong>Appendix</strong> B,Milestones.5.1.1 Reserved.5.1.2 Agreement on Dates.5.1.2.1 5.1.1 Standard Option. If the dates designated by InterconnectionCustomer are acceptable to <strong>Transmission</strong> Provider, <strong>Transmission</strong>Provider shall so notify Interconnection Customer within thirty (30)Calendar Days, and <strong>Transmission</strong> Provider shall design, procure,and construct <strong>Transmission</strong> Provider's Interconnection Facilities andNetwork Upgrades, using Reasonable Efforts to complete<strong>Transmission</strong> Provider's Interconnection Facilities and NetworkUpgrades by the dates set forth in <strong>Appendix</strong> B, Milestones.<strong>Transmission</strong> Provider shall not be required to undertake any actionwhich is inconsistent with its standard safety practices, its materialand equipment specifications, its design criteria and constructionprocedures, its laborlabour agreements, and Applicable Laws andRegulations. In the event <strong>Transmission</strong> Provider reasonably expectsthat it will not be able to complete <strong>Transmission</strong> Provider'sInterconnection Facilities and Network Upgrades by the specifieddates, <strong>Transmission</strong> Provider shall promptly provide written noticeto Interconnection Customer and shall undertake Reasonable Effortsto meet the earliest dates thereafter.5.1.2 Alternate Option. If the dates designated by Interconnection Customer areacceptable to <strong>Transmission</strong> Provider, <strong>Transmission</strong> Provider shall so notifyInterconnection Customer within thirty (30) Calendar Days, and shall assumeresponsibility for the design, procurement and construction of <strong>Transmission</strong>Provider’s Interconnection Facilities by the designated dates.If <strong>Transmission</strong> Provider subsequently fails to complete <strong>Transmission</strong>Provider's Interconnection Facilities by the In-Service Date, to the extentnecessary to provide back feed power; or fails to complete Network Upgradesby the Initial Synchronization Date to the extent necessary to allow for TrialOperation at full power output, unless other arrangements are made by theParties for such Trial Operation; or fails to complete the Network Upgrades bythe Commercial Operation Date, as such dates are reflected in <strong>Appendix</strong> B,- 16 -DM_VAN/<strong>BC</strong>T0007-<strong>BC</strong>T00129/6206155.10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!