taxing authority or power; provided, however, that such term does not include InterconnectionCustomer, <strong>Transmission</strong> Provider, or any Affiliate thereof.Hazardous Substances shall mean any chemicals, materials or substances defined as orincluded in the definition of “hazardous substances,” “hazardous wastes,” “hazardous materials,”“hazardous constituents,” “restricted hazardous materials,” “extremely hazardous substances,”“toxic substances,” “radioactive substances,” “contaminants,” “pollutants,” “toxic pollutants” orwords of similar meaning and regulatory effect under any applicable Environmental Law, or anyother chemical, material or substance, exposure to which is prohibited, limited or regulated byany applicable Environmental Law.Holiday shall mean a statutory holiday in British Columbia.Initial Synchronization Date shall mean the date upon which the Generating Facility is initiallysynchronized and upon which Trial Operation begins.In-Service Date shall mean the date upon which the Interconnection Customer reasonablyexpects it will be ready to begin use of the <strong>Transmission</strong> Provider’s Interconnection Facilities toobtain back feed power.Interconnection Customer shall mean any entity, including the <strong>Transmission</strong> Provider,<strong>Transmission</strong> Owner or any of the Affiliates or subsidiaries of either, that proposes tointerconnect its Generating Facility with the <strong>Transmission</strong> Provider’s <strong>Transmission</strong> System.Interconnection Customer’s Interconnection Facilities shall mean all facilities and equipment,as identified in <strong>Appendix</strong> A of thethis Standard Large Generator Interconnection Agreement, thatare located between the Generating Facility and the Point of Change of Ownership, includingany modification, addition, or upgrades to such facilities and equipment necessary to physicallyand electrically interconnect the Generating Facility to the <strong>Transmission</strong> Provider’s <strong>Transmission</strong>System. Interconnection Customer’s Interconnection Facilities are sole use facilities.Interconnection Facilities shall mean the <strong>Transmission</strong> Provider’s Interconnection Facilitiesand the Interconnection Customer’s Interconnection Facilities. Collectively, InterconnectionFacilities include all facilities and equipment between the Generating Facility and the Point ofInterconnection, including any modification, additions or upgrades that are necessary tophysically and electrically interconnect the Generating Facility to the <strong>Transmission</strong> Provider’s<strong>Transmission</strong> System. Interconnection Facilities are sole use facilities and shall not includeDistribution Upgrades, Stand Alone Network Upgrades or Network Upgrades.Interconnection Facilities Study shall mean a study conducted by the <strong>Transmission</strong> Provider ora third party consultant for the Interconnection Customer to determine a list of facilities(including <strong>Transmission</strong> Provider’sthe Interconnection Facilities and Network Upgrades asidentified in the Interconnection System Impact Study), the cost of those facilities, and the timerequired to interconnect the Generating Facility with the <strong>Transmission</strong> Provider’s <strong>Transmission</strong>System. The scope of the study is defined in Section 8 of the Standard Large GeneratorInterconnection Procedures.Interconnection Facilities Study Agreement shall mean the formof agreement contained in <strong>Appendix</strong> 4 of the Standard Large Generator Interconnection- 5 -DM_VAN/<strong>BC</strong>T0007-<strong>BC</strong>T00129/6206155.10
Procedures for conducting the Interconnection Facilities StudyStudy dated in respect of theGenerating Facility.Interconnection Feasibility Study shall mean a preliminary evaluation of the system impactand cost of interconnecting the Generating Facility to the <strong>Transmission</strong> Provider’s <strong>Transmission</strong>System, the scope of which is described in Section 6 of the Standard Large GeneratorInterconnection Procedures.Interconnection Feasibility Study Agreement shall mean the formof agreement contained in <strong>Appendix</strong> 2 of the Standard Large Generator InterconnectionProcedures for conducting the Interconnection Feasibility Study.the Interconnection FeasibilityStudy dated in respect of the Generating Facility.Interconnection Request shall mean an Interconnection Customer’s request, in the form of<strong>Appendix</strong> 1 to the Standard Large Generator Interconnection Procedures, in accordance with theTariff, to interconnect a new Generating Facility, or to increase the capacity of, or make aMaterial Modification to the operating characteristics of, an existing Generating Facility that isinterconnected with the <strong>Transmission</strong> Provider’s <strong>Transmission</strong> Systemin respect of theGenerating Facility.Interconnection Service shall mean the service provided by the <strong>Transmission</strong> Providerassociated with interconnecting the Interconnection Customer’s Generating Facility to the<strong>Transmission</strong> Provider’s <strong>Transmission</strong> System and enabling it to receive electric energy andcapacity from the Generating Facility at the Point of Interconnection, pursuant to the terms ofthethis Standard Large Generator Interconnection Agreement and, if applicable, the<strong>Transmission</strong> Provider’s Tariff.Interconnection Study shall mean any of the following studies: the Interconnection FeasibilityStudy, the Interconnection System Impact Study, and the Interconnection Facilities Studydescribed in the Standard Large Generator Interconnection Procedures.Interconnection System Impact Study shall mean an engineering study that evaluates theimpact of the proposed interconnection on the safety and reliability of <strong>Transmission</strong> Provider’s<strong>Transmission</strong> System and, if applicable, an Affected System. The study shall identify and detailthe system impacts that would result if the Generating Facility were interconnected withoutproject modifications or system modifications, focusing on the Adverse System Impactsidentified in the Interconnection Feasibility Study, or to study potential impacts, including butnot limited to those identified in the Scoping Meeting as described in the Standard LargeGenerator Interconnection Procedures.Interconnection System Impact Study Agreement shall mean the form of agreement containedin <strong>Appendix</strong> 3 of the Standard Large Generator Interconnection Procedures for conducting theInterconnection System Impact Study.IRS shall mean the Internal Revenue Service.Interest means interest calculated in accordance with Attachment K of the Tariff.- 6 -DM_VAN/<strong>BC</strong>T0007-<strong>BC</strong>T00129/6206155.10
- Page 4 and 5:
TABLE OF CONTENTS(continued)PageSec
- Page 7 and 8:
TABLE OF CONTENTSPageSection 1.Defi
- Page 9 and 10:
Effective Date shall mean the date
- Page 11 and 12:
Provider's Transmission System. Int
- Page 13 and 14:
sale to third parties or otherwise
- Page 16 and 17:
2.3 Base Case Data.Transmission Pro
- Page 18 and 19:
3.3 Valid Interconnection Request.L
- Page 20 and 21:
Interconnection Requests that have
- Page 22 and 23:
4.2 Clustering.At Transmission Prov
- Page 24 and 25:
4.4.1 Permitted Modifications Befor
- Page 26 and 27:
as of the effective date of this LG
- Page 28 and 29:
6.3 Interconnection Feasibility Stu
- Page 30 and 31:
case of Clustering, the Interconnec
- Page 32 and 33:
Transmission Provider may invoice I
- Page 34 and 35:
interconnection, which cannot be mi
- Page 36 and 37: 11.2 Negotiation.Notwithstanding Se
- Page 38 and 39: completion of Network Upgrades that
- Page 40 and 41: ecomes, publicly known, through no
- Page 42 and 43: a state regulatory body conducting
- Page 44 and 45: of such third party study. Such thi
- Page 46 and 47: Unless otherwise provided in these
- Page 48 and 49: 6. Applicable deposit amount as spe
- Page 50 and 51: FIELD TIME CONSTANT DATA (SEC)Open
- Page 52 and 53: GENERATOR STEP-UP TRANSFORMER DATA
- Page 54 and 55: TABLE OF CONTENTSPageINDUCTION GENE
- Page 56 and 57: Request pursuant to Section 4.4, th
- Page 58 and 59: ASSUMPTIONS USED IN CONDUCTING THEI
- Page 60 and 61: 3.0 The scope of the Interconnectio
- Page 62 and 63: IN WITNESS THEREOF, the Parties hav
- Page 64 and 65: NOW, THEREFORE, in consideration of
- Page 66 and 67: Attachment B To Appendix 3Combined
- Page 68 and 69: Bus length from generation to inter
- Page 70 and 71: may be required to provide transmis
- Page 72 and 73: Document comparison done by DeltaVi
- Page 74 and 75: TABLE OF CONTENTSPageTABLE OF CONTE
- Page 76 and 77: TABLE OF CONTENTS(continued)Page- i
- Page 78 and 79: TABLE OF CONTENTS(continued)PageART
- Page 80 and 81: TABLE OF CONTENTS(continued)Page28.
- Page 82 and 83: STANDARD LARGE GENERATOR INTERCONNE
- Page 84 and 85: Confidential Information shall mean
- Page 88 and 89: Joint Operating Committee shall be
- Page 90 and 91: usiness relationship between Interc
- Page 92 and 93: 2.3.4 2.3.3 Notwithstanding Article
- Page 94 and 95: 4.1.1.2 Transmission Delivery Servi
- Page 96 and 97: Customer's Large Generating Facilit
- Page 98 and 99: Milestones; Transmission Provider s
- Page 100 and 101: (11) Interconnection Customer shall
- Page 102 and 103: time, request a progress report fro
- Page 104 and 105: normal operation of the Granting Pa
- Page 106 and 107: epresentation in clause (iii), abov
- Page 108 and 109: service, (i) Interconnection Custom
- Page 110 and 111: 5.17.9 Taxes Other Than Income Taxe
- Page 112 and 113: 6.3 Right to Observe Testing. Each
- Page 114 and 115: 8.2 Remote Terminal Unit. Prior to
- Page 116 and 117: 9.6.2.1 Governors and Regulators. W
- Page 118 and 119: The following provisions shall appl
- Page 120 and 121: with the protective requirements of
- Page 122 and 123: operating, maintaining, repairing,
- Page 124 and 125: if any, created by the Network Upgr
- Page 126 and 127: esolution of such dispute. If Inter
- Page 128 and 129: 13.6 Interconnection Customer Autho
- Page 130 and 131: Breach, the non-breaching Party sha
- Page 132 and 133: 18.3.1 Employers' Liability and Wor
- Page 134 and 135: Customer shall have the right to as
- Page 136 and 137:
waiver by either Party or any other
- Page 138 and 139:
Article 23Article 23. . Environment
- Page 140 and 141:
with the provisions of this LGIASGI
- Page 142 and 143:
usiness or financial relationships
- Page 144 and 145:
29.1.5 Ensure that information is b
- Page 146 and 147:
LGIA shall limit the rights of the
- Page 148 and 149:
Appendix B to LGIASGIAMilestones- 6
- Page 150 and 151:
Appendix D to LGIASGIASecurity Arra
- Page 152 and 153:
Appendix FE to LGIASGIAAddresses fo
- Page 154 and 155:
Section IV of Annex A thereof, and,
- Page 156 and 157:
Appendix G to SGIADispute Resolutio
- Page 158 and 159:
Appendix H to SGIATransmission Owne
- Page 160:
Document comparison done by DeltaVi