operating, maintaining, repairing, and replacing Interconnection Customer'sInterconnection Facilities; and (2) operation, maintenance, repair and replacement of<strong>Transmission</strong> Provider's Interconnection Facilities.Article 11Article 11. . Performance Obligation11.1 Interconnection Customer Interconnection Facilities. Interconnection Customer shalldesign, procure, construct, install, own and/or control Interconnection CustomerInterconnection Facilities described in <strong>Appendix</strong> A, Interconnection Facilities, andNetwork Upgrades and Distribution Upgrades, at its sole expense.11.2 <strong>Transmission</strong> Provider's Interconnection Facilities. <strong>Transmission</strong> Provider or<strong>Transmission</strong> Owner shall design, procure, construct, install, own and/or control the<strong>Transmission</strong> Provider's Interconnection Facilities described in <strong>Appendix</strong> A,Interconnection Facilities, and Network Upgrades and Distribution Upgrades, at the soleexpense of the Interconnection Customer.11.3 Network Upgrades and Distribution Upgrades. <strong>Transmission</strong> Provider or<strong>Transmission</strong> Owner shall design, procure, construct, install, and own the NetworkUpgrades and Distribution Upgrades described in <strong>Appendix</strong> A, Interconnection Facilities,Network Upgrades and Distribution Upgrades. The Interconnection Customer shall beresponsible for all costs related to Distribution and Network Upgrades. Unless<strong>Transmission</strong> Provider or <strong>Transmission</strong> Owner elects to fund the capital for the NetworkUpgrades, they shall be solely funded by Interconnection Customer.11.3.1 On the Commercial Operation Date, Interconnection Customer shall also fundany amounts that <strong>Transmission</strong> Provider is obligated to pay to third parties inaccordance with provisions in other Standard Generator InterconnectionAgreements similar to Section 11.4.2 of this Agreement as a result of theGenerating Facility’s use of network upgrades funded by such third parties.11.4 <strong>Transmission</strong> Credits and Repayments.11.4.1 Repayment of Amounts Advanced for Network Upgrades. InterconnectionCustomer shall be entitled to a cash repayment or credits against the non-usagesensitive portion of transmission charges, equal to the total amount paid to<strong>Transmission</strong> Provider and Affected System Operator, if any, for the NetworkUpgrades, including any tax gross-up or other tax-related payments associatedwith Network Upgrades, and not refunded toNetwork Upgrades and pursuantto Section 11.3.1, but less any amounts received by Interconnection Customerpursuant to Article 5.17.8 or otherwise, to be paid to Interconnection Customeron a dollar-for-dollar basis for the non-usage sensitive portion of transmissioncharges, as payments are made under <strong>Transmission</strong> Provider's Tariff andAffected System's Tariff for transmission services with respect to the LargeGenerating Facility. Any repayment shall include interest calculated inaccordance with the methodology set forth in FERC's regulations at 18 C.F.R.§35.19a(a)(2)(ii) from the date of any payment for Network Upgrades through- 41 -DM_VAN/<strong>BC</strong>T0007-<strong>BC</strong>T00129/6206155.10
the date on which the Interconnection Customer receives a repayment of suchpayment pursuant to this subparagraph. Interconnection Customer may assignsuch repayment rights to any person.Section 11.4.2, in accordance withAttachment K of the Tariff.Notwithstanding the foregoing, Interconnection Customer, <strong>Transmission</strong>Provider, and Affected System Operator may adopt any alternative paymentschedule that is mutually [agreeable so long as <strong>Transmission</strong> Provider andAffected System Operator take one of the following actions no later than fiveyears from the Commercial Operation Date: (1) return to InterconnectionCustomer any amounts advanced for Network Upgrades not previously repaid,or (2) declare in writing that <strong>Transmission</strong> Provider or Affected SystemOperator will continue to provide payments to Interconnection Customerpursuant to this subparagraph until all amounts advanced for NetworkUpgrades have been repaid.11.4.2 Repayment on Failure to Achieve Commercial Operation. If the LargeGenerating Facility fails to achieve commercial operation, but it or anotherGenerating Facility is later constructed andCommercial Operation, thisAgreement is terminated, and another generating facility subsequently makesuse of the Network Upgrades constructed pursuant to this Agreement,<strong>Transmission</strong> Provider and Affected System Operator shall at that timereimburse Interconnection Customer for the amounts advanced byInterconnection Customer for the those Network Upgrades. used by the othergenerating facility, as reasonably determined by <strong>BC</strong>TC. This Section 11.4.2shall survive the termination of this Agreement.11.4.2 Special Provisions for Affected Systems. Unless <strong>Transmission</strong> Providerprovides, under the LGIA, for the repayment of amounts advanced to AffectedSystem Operator for Network Upgrades, Interconnection Customer andAffected System Operator shall enter into an agreement that provides for suchrepayment. The agreement shall specify the terms governing payments to bemade by Interconnection Customer to the Affected System Operator as well asthe repayment by the Affected System Operator.11.4.3 Deferral Credits. Where Interconnection Customer satisfies the eligibilitycriteria set out in Attachment N to the Tariff, Interconnection Customer shall,in addition to any payments and credits provided for in Sections 11.4.1 and11.4.2, be entitled to Deferral Credits against the non-usage sensitive portionof transmission charges as provided for in Attachment N to the Tariff.11.4.4 11.4.3 Other Rights. Notwithstanding any other provision of this LGIASGIA,nothing herein shall be construed as relinquishing or foreclosing any rights,including but not limited to firm transmission rights, capacity rights,transmission congestion rights, or transmission credits, that InterconnectionCustomer, shall be entitled to, now or in the future under any other agreementor tariff as a result of, or otherwise associated with, the transmission capacity,- 42 -DM_VAN/<strong>BC</strong>T0007-<strong>BC</strong>T00129/6206155.10
- Page 4 and 5:
TABLE OF CONTENTS(continued)PageSec
- Page 7 and 8:
TABLE OF CONTENTSPageSection 1.Defi
- Page 9 and 10:
Effective Date shall mean the date
- Page 11 and 12:
Provider's Transmission System. Int
- Page 13 and 14:
sale to third parties or otherwise
- Page 16 and 17:
2.3 Base Case Data.Transmission Pro
- Page 18 and 19:
3.3 Valid Interconnection Request.L
- Page 20 and 21:
Interconnection Requests that have
- Page 22 and 23:
4.2 Clustering.At Transmission Prov
- Page 24 and 25:
4.4.1 Permitted Modifications Befor
- Page 26 and 27:
as of the effective date of this LG
- Page 28 and 29:
6.3 Interconnection Feasibility Stu
- Page 30 and 31:
case of Clustering, the Interconnec
- Page 32 and 33:
Transmission Provider may invoice I
- Page 34 and 35:
interconnection, which cannot be mi
- Page 36 and 37:
11.2 Negotiation.Notwithstanding Se
- Page 38 and 39:
completion of Network Upgrades that
- Page 40 and 41:
ecomes, publicly known, through no
- Page 42 and 43:
a state regulatory body conducting
- Page 44 and 45:
of such third party study. Such thi
- Page 46 and 47:
Unless otherwise provided in these
- Page 48 and 49:
6. Applicable deposit amount as spe
- Page 50 and 51:
FIELD TIME CONSTANT DATA (SEC)Open
- Page 52 and 53:
GENERATOR STEP-UP TRANSFORMER DATA
- Page 54 and 55:
TABLE OF CONTENTSPageINDUCTION GENE
- Page 56 and 57:
Request pursuant to Section 4.4, th
- Page 58 and 59:
ASSUMPTIONS USED IN CONDUCTING THEI
- Page 60 and 61:
3.0 The scope of the Interconnectio
- Page 62 and 63:
IN WITNESS THEREOF, the Parties hav
- Page 64 and 65:
NOW, THEREFORE, in consideration of
- Page 66 and 67:
Attachment B To Appendix 3Combined
- Page 68 and 69:
Bus length from generation to inter
- Page 70 and 71:
may be required to provide transmis
- Page 72 and 73: Document comparison done by DeltaVi
- Page 74 and 75: TABLE OF CONTENTSPageTABLE OF CONTE
- Page 76 and 77: TABLE OF CONTENTS(continued)Page- i
- Page 78 and 79: TABLE OF CONTENTS(continued)PageART
- Page 80 and 81: TABLE OF CONTENTS(continued)Page28.
- Page 82 and 83: STANDARD LARGE GENERATOR INTERCONNE
- Page 84 and 85: Confidential Information shall mean
- Page 86 and 87: taxing authority or power; provided
- Page 88 and 89: Joint Operating Committee shall be
- Page 90 and 91: usiness relationship between Interc
- Page 92 and 93: 2.3.4 2.3.3 Notwithstanding Article
- Page 94 and 95: 4.1.1.2 Transmission Delivery Servi
- Page 96 and 97: Customer's Large Generating Facilit
- Page 98 and 99: Milestones; Transmission Provider s
- Page 100 and 101: (11) Interconnection Customer shall
- Page 102 and 103: time, request a progress report fro
- Page 104 and 105: normal operation of the Granting Pa
- Page 106 and 107: epresentation in clause (iii), abov
- Page 108 and 109: service, (i) Interconnection Custom
- Page 110 and 111: 5.17.9 Taxes Other Than Income Taxe
- Page 112 and 113: 6.3 Right to Observe Testing. Each
- Page 114 and 115: 8.2 Remote Terminal Unit. Prior to
- Page 116 and 117: 9.6.2.1 Governors and Regulators. W
- Page 118 and 119: The following provisions shall appl
- Page 120 and 121: with the protective requirements of
- Page 124 and 125: if any, created by the Network Upgr
- Page 126 and 127: esolution of such dispute. If Inter
- Page 128 and 129: 13.6 Interconnection Customer Autho
- Page 130 and 131: Breach, the non-breaching Party sha
- Page 132 and 133: 18.3.1 Employers' Liability and Wor
- Page 134 and 135: Customer shall have the right to as
- Page 136 and 137: waiver by either Party or any other
- Page 138 and 139: Article 23Article 23. . Environment
- Page 140 and 141: with the provisions of this LGIASGI
- Page 142 and 143: usiness or financial relationships
- Page 144 and 145: 29.1.5 Ensure that information is b
- Page 146 and 147: LGIA shall limit the rights of the
- Page 148 and 149: Appendix B to LGIASGIAMilestones- 6
- Page 150 and 151: Appendix D to LGIASGIASecurity Arra
- Page 152 and 153: Appendix FE to LGIASGIAAddresses fo
- Page 154 and 155: Section IV of Annex A thereof, and,
- Page 156 and 157: Appendix G to SGIADispute Resolutio
- Page 158 and 159: Appendix H to SGIATransmission Owne
- Page 160: Document comparison done by DeltaVi