The following provisions shall apply to any interruption or reduction permittedunder this Article 9.7.2:9.7.2.1 The interruption or reduction shall continue only for so long asreasonably necessary under Good Utility Practice;9.7.2.2 Any such interruption or reduction shall be made on an equitable,non-discriminatory basis with respect to all generating facilitiesdirectly connected to the <strong>Transmission</strong> System;9.7.2.3 When the interruption or reduction must be made undercircumstances which do not allow for advance notice, <strong>Transmission</strong>Provider shall notify Interconnection Customer by telephone as soonas practicable of the reasons for the curtailment, interruption, orreduction, and, if known, its expected duration. Telephonenotification shall be followed by written notification as soon aspracticable;9.7.2.4 Except during the existence of an Emergency Condition, when theinterruption or reduction can be scheduled without advance notice,<strong>Transmission</strong> Provider shall notify Interconnection Customer inadvance regarding the timing of such scheduling and further notifyInterconnection Customer of the expected duration. <strong>Transmission</strong>Provider shall coordinate with Interconnection Customer usingGood Utility Practice to schedule the interruption or reductionduring periods of least impact to Interconnection Customer and<strong>Transmission</strong> Provider;9.7.2.5 The Parties shall cooperate and coordinate with each other to theextent necessary in order to restore the Large Generating Facility,Interconnection Facilities, and the <strong>Transmission</strong> System to theirnormal operating state, consistent with system conditions and GoodUtility Practice.9.7.3 Under-Frequency and Over Frequency Conditions. The <strong>Transmission</strong>System is designed to automatically activate a load-shed program as requiredby the Applicable Reliability Council in the event of an under-frequencysystem disturbance. Interconnection Customer shall implement underfrequencyand over-frequency relay set points for the Large GeneratingFacility as required by the Applicable Reliability Council to ensure "ridethrough" capability of the <strong>Transmission</strong> System. Large Generating Facilityresponse to frequency deviations of pre-determined magnitudes, both underfrequencyand over-frequency deviations, shall be studied and coordinatedwith <strong>Transmission</strong> Provider in accordance with Good Utility Practice. Theterm "ride through" as used herein shall mean the ability of a GeneratingFacility to stay connected to and synchronized with the <strong>Transmission</strong> System- 37 -DM_VAN/<strong>BC</strong>T0007-<strong>BC</strong>T00129/6206155.10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!