13.07.2015 Views

Appendix D - BC Hydro - Transmission

Appendix D - BC Hydro - Transmission

Appendix D - BC Hydro - Transmission

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

time, request a progress report from the other Party. If, at any time, InterconnectionCustomer determines that the completion of <strong>Transmission</strong> Provider's InterconnectionFacilities will not be required until after the specified In-Service Date, InterconnectionCustomer will provide written notice to <strong>Transmission</strong> Provider of such later date uponwhich the completion of <strong>Transmission</strong> Provider's Interconnection Facilities will berequired.5.8 Information Exchange. As soon as reasonably practicable after the Effective Date, theParties shall exchange information regarding the design and compatibility of the Parties'Interconnection Facilities and compatibility of the Interconnection Facilities with<strong>Transmission</strong> Provider's <strong>Transmission</strong> System, and shall work diligently and in goodfaith to make any necessary design changes.5.9 Limited Operation. If any of <strong>Transmission</strong> Provider's Interconnection Facilities orNetwork Upgrades are not reasonably expected to be completed prior to the CommercialOperation Date of the Large Generating Facility, <strong>Transmission</strong> Provider shall, upon therequest and at the expense of Interconnection Customer, perform operating studies on atimely basis to determine the extent to which the Large Generating Facility andInterconnection Customer Interconnection Facilities may operate prior to the completionof <strong>Transmission</strong> Provider's Interconnection Facilities or Network Upgrades consistentwith Applicable Laws and Regulations, Applicable Reliability Standards, Good UtilityPractice, and this LGIASGIA. <strong>Transmission</strong> Provider shall permit InterconnectionCustomer to operate the Large Generating Facility and Interconnection CustomerInterconnection Facilities in accordance with the results of such studies.5.10 Interconnection Customer's Interconnection Facilities ('ICIF'). InterconnectionCustomer shall, at its expense, design, procure, construct, own and install the ICIF, as setforth in <strong>Appendix</strong> A, Interconnection Facilities, and Network Upgrades and DistributionUpgrades.5.10.1 Interconnection Customer’s Interconnection Facility Specifications.Interconnection Customer shall submit initial specifications for the ICIF,including System Protection Facilities, to <strong>Transmission</strong> Provider at least onehundred eighty (180) Calendar Days prior to the Initial Synchronization Date;and final specifications for review and comment at least ninety (90) CalendarDays prior to the Initial Synchronization Date. <strong>Transmission</strong> Provider shallreview such specifications to ensure that the ICIF are compatible with thetechnical specifications (including the Technical InterconnectionRequirements), operational control, and safety requirements of <strong>Transmission</strong>Provider and comment on such specifications within thirty (30) Calendar Daysof Interconnection Customer's submission. All specifications providedhereunder shall be deemed confidentialConfidential Information.5.10.2 <strong>Transmission</strong> Provider's Review. <strong>Transmission</strong> Provider's review ofInterconnection Customer's final specifications shall not be construed asconfirming, endorsing, or providing a warranty as to the design, fitness, safety,durability or reliability of the Large Generating Facility, or the ICIF.- 21 -DM_VAN/<strong>BC</strong>T0007-<strong>BC</strong>T00129/6206155.10

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!