RDE 92003-01-R/05.99ÜberprüfungshinweiseInspection notesReparaturanleitung A4VGRepair Instructions A4VG62 Alle Lager erneuern.Replace all bearings.63 Kontrolle!1. Verzahnung, ausgeschlagen, Passungsrost.2. Lauffläche.3. Einlaufrillen vom Wellendichtring.Check!1. Splines for damage or fretting.2. Running surfaces.3. Groove cut by shaft seal.64 Stellkolbenlaufbüchse (1) riefenfrei, nicht ausgelaufen.Check that the control piston guide bush (1) isfree of grooves and has not worn out.65 Kontrolle!Stellkolben (1) riefenfrei.Check!Control piston (1) is not scored.22 Brueninghaus Hydromatik244 TX51-19M-1-SM 01-29-02 <strong>57.4400.0100</strong>