160 mmD Installation GB Installation F Installation E Instalación I InstallazioneP instalação NL installatie FIN Asennus SE Installation N Installasjon12328mm86 mm 47 mm4<strong>P2</strong><strong>T3</strong>5 6<strong>P1</strong><strong>T2</strong><strong>T1</strong>230 VAC50HzPPL IMP 1700 A


1<strong>T1</strong><strong>T3</strong><strong>P2</strong><strong>P1</strong><strong>T2</strong>


Parameter Nr 4 =GefrierschutzGefrierschutz ausgeschaltet (Werkseinstellung)Montage und BedienungsanleitungBasic Solar Control LED<strong>T1</strong>Vorgabe von t°C zur Schutzeinschaltung (Einstellung von -5 bis 5 °C)Parameter Nr 5 = ÜberhitzungsschutzÜberhitzungsschutz ausgeschaltet (Werkseinstellung)Zusatzfunktionen:1 Zusatz-Wärmeregler1 Sensor<strong>T3</strong><strong>P2</strong>Überhitzungsschutz eingeschaltet<strong>P1</strong>Parameter Nr 6 = Höchsttemperatur des KollektorsWert zur Einschaltung des Überhitzungsschutzes (Werkseinstellung 140°C)Einstellung von 100°C (10) bis 200°C (20)Parameter Nr 7 = RöhrenkollektorDas System wird mit einem Flachkollektor betrieben (Werkseinstellung)Das System wird mit einem Röhrenkollektor betrieben (Vakuumkollektor)Alle 30 min schaltet sich die Pumpe für 30 sec ein, um den richtigen Temperaturwert beimKollektor zu messen und einen kurzen Beladungszyklus zu verhindern.Parameter Nr 8 = Zusatzfunktion für <strong>P2</strong> (nur in Betrieb, wenn der Sensor <strong>T3</strong> montiert ist)Anschluss <strong>P2</strong> wird zur Steuerung der Nachheizung benutzt (Werkseinstellung).Anschluss <strong>P2</strong> wird zur Kühlung des Hauptbehälters benutzt.(Lagerung der Überschussenergie in einem anderen Speicher (z.B. Schwimmbad, Tank)Parameter Nr <strong>P1</strong> = Test Hauptpumpe (Werkseinstellung <strong>P1</strong>:A)TECHNISCHE DATENBetriebstemperatur 0°C - 50°CTemperatur-Einstellbereich:Dt (Temperaturdifferenz zw. Kollektor <strong>T1</strong> und Behälter <strong>T2</strong>)4°C - 30°C (39°F - 86°F)Wassertemperatur (gewünschte maximale t°C im Behälter <strong>T2</strong>) 30°C - 90°C (86°F - 194°F)Nachheizung (Vorgabe Einstelllevel <strong>P2</strong>)0°C - 85°C (0°F – 185°F)Elektrische SchutzartIP42Elektrischer Anschluss230Vac +/- 10% 50HzAnschlüsse:<strong>P1</strong> (Hauptpumpe):<strong>P2</strong> (Nachheizung):Sensoren:<strong>T1</strong> (Kollektor):<strong>T2</strong> (Behälter):<strong>T3</strong> (Zusatzsensor für Steuerung <strong>P2</strong>):Software-VersionDISPLAY<strong>T2</strong>Relais 8A 250VAC.Relais 8A 250VACPT 1000 (1,5 m, max. 180°C)PT 1000 (3 m, max. 105°C)PT 1000 (3 m, max. 105°C)Version wird beim Start U 1._angezeigtAutomatik-Betrieb: Die Pumpe läuft gemäß “dt”- Wert.Manuell-Betrieb: Die Pumpe läuft 4 Stunden und geht danach automatisch zum Automatik-Betrieb zurück.Manuell-Betrieb: Pumpe ausgeschaltet.Parameter Nr <strong>P2</strong> = Test Nachheizung(in Betrieb nur, wenn Sensor <strong>T3</strong> montiert ist)Manuell-Betrieb: Nachheizung eingeschaltet.Manuell-Betrieb:Nachheizungausgeschaltet.1: Anzeige für die Temperatur am Behälterboden(Display “7” zeigt die gemessene t°C).2: Anzeige Pumpe (blinkt bei Betrieb)3: Anzeige Nachheizung ( blinkt bei Betrieb)4: Max.t°C im Behälter (Einstellung)5: dt Temperaturdifferenz zwischen Kollektor”6” und Behälter ”1”. (Einstellung)6: Anzeige t°C Kollektor (Display “7” zeigt diegemessene Temperatur). 57: Display (rot).4 3A: Minus-Taste (zur Wertreduzierung)B: Menü-Taste (zur Änderung des angezeigten Wertesu. der Parameternummer)C: Plus-Taste (zur Werterhöhung)26 71A B CPPL IMP 1705


FUNKTION UND BESCHREIBUNGFunktion der Hauptpumpe (<strong>P1</strong>):Die Pumpe läuft:- wenn die Kollektortemperatur (<strong>T1</strong>) höher als die im Behälter ist (<strong>T2</strong>) + dt, welche vom Parameter-Menü geregelt wird(Nr 1 => Werkseinstellung 8°C)- 15 sec, wenn die Pumpe 5 Tage nicht in Betrieb war (Funktion Ausschalten gegen Blockierung).Die Pumpe schaltet sich aus:- wenn die Kollektortemperatur (<strong>T1</strong>) unter die des Behälters sinkt (<strong>T2</strong>) + dt/2.Beispiel:dt-Wertdt-Wert / 2dt = <strong>T1</strong> - <strong>T2</strong>Zusatzfunktion Nachheizung (<strong>P2</strong>):Um diese Funktion zu benutzen, muss man den Zusatzsensor <strong>T3</strong> montieren.Dieser Anschluss wird gewöhnlich zur Steuerung der Nachheizung des Behälters (elektrischen Heizelementes oderWarmwasserbereiters…) benutztEinschaltung:- Wenn die Wassertemperatur (<strong>T3</strong>) im Behälter unter den vorgegebenen Wert sinkt, der von dem Parameter-Menügeregelt wird (Nr 3 => Werkswert 50°C)Ausschaltung:- Wenn die Wassertemperatur (<strong>T3</strong>) um 5°C über dem vorgegebenen Wert liegt.Beispiel:Wert Т 3 + 5°CWert <strong>T3</strong>Wassertemperatur im Behälter<strong>T3</strong> (°C)Kollektor- und Systemschutz:Gefrier- und SchneeschutzDiese Funktion hält die Temperatur des Kollektors <strong>T1</strong> über der vorgegebenen Gefriertemperatur (wird vondem Parameter-Menü Nr 4 geregelt), indem sie die Pumpe <strong>P1</strong> einschaltet.Diese Funktion schützt vor Schneeansammlung auf dem Kollektor und erhöht die Effektivität tagsüber unddient zur Verhinderung von Beschädigungen der Solarflüssigkeit.ACHTUNG: Empfehlenswert ist diese Funktion in sehr kalten Regionen nicht zu benutzen, damit nicht einzu hoher Anteil der im Behälter gelagerten Energie verbraucht wird.Überhitzungsschutz des KollektorsDiese Funktion dient zum Schutz der Kollektorflüssigkeit.Sie schaltet die Pumpe ein, wenn die Kollektortemperatur <strong>T1</strong> den im Parameter Nr 6 vorgegebenen Wert(werksmäßig 140°C) übersteigt, selbst beim Erreichen der Höchsttemperatur. (Die Pumpe wirdausgeschaltet, wenn die Wassertemperatur im Behälter 95°C erreicht).Überhitzungsschutz des SystemsWenn die Behältertemperatur 95°C beträgt (zulässige Höchsttemperatur), und die Kollektortemperatur <strong>T1</strong>um 5°C niedriger ist, wird die Pumpe eingeschaltet, um den Behälter bis auf die vorgegebene Temperaturabzukühlen. Diese Funktion lässt sich von dem Parameter-Menü ausschalten (Nr 5, werksmäßigausgeschaltet).Sensorenfehler:Kollektor Sensor (<strong>T1</strong>): Pumpe <strong>P1</strong> läuft nicht (Err 1 und die jeweilige Leuchtdiode blinkt).Behälter Sensor (<strong>T2</strong>): Pumpe <strong>P1</strong> läuft nicht (Err2 und die jeweilige Leuchtdiode blinkt).Zusatzsensor (<strong>T3</strong>): Der Zusatzerhitzer ist ausgeschaltet. (Err 3)Entsprechender Wert für Sensor P<strong>T1</strong>000: (wird mittels Ohmmeter überprüft)-10°C0°C10°C20°C30°C40°C50°C960 Ω1000 Ω1039 Ω1077 Ω1116 Ω1155 Ω1194 ΩPARAMETER MENÜ60°C70°C80°C90°C100°C120°C140°C1232 Ω1271 Ω1309 Ω1347 Ω1385 Ω1461 Ω1535 ΩDrücken Sie und für 2 sec, um sich in das Parameter-Menü einzuloggen.Zusatzfunktion Kühlung (<strong>P2</strong>):Die Funktion Kühlung wird gewöhnlich zur Kühlung des Haupt-Solarbehälters bei starker Sonnenstrahlung benutzt .Diese Funktion ermöglicht die Lagerung der Überschussenergie in einem anderen Behälter (Schwimmbecken, Tank u.a.)Einschaltung:- Wenn die Wassertemperatur (<strong>T3</strong>) im Behälter die Obergrenze des vorgegebenen Wertes übersteigt, der von demParameter-Menü geregelt wird (Nr 3 => Werkswert 50°C)Ausschaltung:- Wenn die Wassertemperatur (<strong>T3</strong>) um 5°C unter dem vorgegebenen Wert liegt.Beispiel:Wassertemperatur im Behälter Т3 (°C)Danach drücken Sie , um einen Parameter zu wählen, den Sie mit oder ändern.Parameter Nr 1 = dtDifferenz zw.der Kollektortemperatur (<strong>T1</strong>) und der des Behälters (<strong>T2</strong>) zum Starten derHauptpumpe (Werkswert 8°C).Parameter Nr 2 =HöchsttemperaturGewünschte Höchsttemperatur des Behälters (werksmäßig 90°C)Wert <strong>T3</strong>Wert <strong>T3</strong> – 5 °CParameter Nr 3 = Vorgabe eines Wertes für einen ZusatzerhitzerVorgabe eines Wertes zur Einschaltung eines Zusatzerhitzers (werksmäßig 50°C)In Betrieb nur, wenn Sensor <strong>T3</strong> eingeschaltet ist


Parameter N°4 = Anti-freeze protectionThe anti-freeze protection is deactivated. (default value)USER GUIDEBasic Solar control<strong>T1</strong>Setting level to start the anti freeze protection. (adjustable -5 to 5°C)Parameter N°5 = Overheat protectionThe overheat protection is deactivated. (default value)The overheat protection is activated.<strong>P1</strong>Extra Funtion:1 Additional heat control1 sensor<strong>T3</strong><strong>P2</strong>Parameter N°6 = Collector Maximum temperatureSetting level to start the overheat protection. (default value 140°C)Adjustable 100°C (10) to 200°C (20)Parameter N°7 = Tubes collectorThe system works with a standard panel collector. (default value)The system works with a tubes collector (Vaccum tubes collector).Each 30 minutes the pump will be activated 30 seconds to measure the correct value on thecollector to avoid short charge cycle.Parameter N°8 = Extra function for <strong>P2</strong> (Effective only if <strong>T3</strong> sensor is connected)<strong>P2</strong> output is used to control an additional heat. (default value)<strong>P2</strong> output is used to cool the primary tank on another heat storage.Parameter N°<strong>P1</strong> = Main pump test (Default value is <strong>P1</strong>:A)TECHNICAL CHARACTERISTICSOperating temperature 0°C - 50°CSetting temperature range:Dt (Temperature difference between Collector <strong>T1</strong> & Tank <strong>T2</strong>) 4°C - 30°C (39°F - 86°F)Water temperature (Max desired Temperature in tank <strong>T2</strong>)30°C - 90°C (86°F - 194°F)Additional heat (Setting level to control <strong>P2</strong>)0°C - 85°C (0°F – 185°F)Electrical ProtectionIP42Power supply230Vac +/- 10% 50HzOutputs:<strong>P1</strong> (Main Pump):<strong>P2</strong> (Extra function):Sensors:<strong>T1</strong> (Collector):<strong>T2</strong> (Tank):<strong>T3</strong> (Additional sensor to control <strong>P2</strong>):Software versionDISPLAY<strong>T2</strong>Relay 8A 250VAC.Relay 8A 250VACPT 1000 (1,5 Meter, Max 180°C)PT 1000 (3 Meters, Max 105°C)PT 1000 (3 Meters, Max 105°C)The version is displayed duringthe init. U 1._Automatic mode: The pump is running in accordance with the “dt” value.Manual mode: The pump is running during 4 hours and return automatically in Automaticmode after this time.Manual mode: The pump is switch off.Parameter N°<strong>P2</strong> = Extra output test (Effective only if <strong>T3</strong> sensor is connected)Manual mode: The additional heat is switch on.Manual mode: The additional heat is switch off.1: Tank bottom temperature indicator (The display“7” shows the measured temperature).2: Pump indicator (Blinks when operating)3: Additional heat indicator (Blinks when operating)4: Max Temperature in the tank (setting level).5: dt Difference temperature between the Collector”6” & Tank ”1”. (setting level)6: Collector temperature indicator (The display “7”shows the measured temperature). 57: Display (Red).4 3A: Minus key (to decrease the current value)B: Menu key (to change the displayed value andparameter number)C: Plus key (to increase the current value)26 71A B CPPL IMP 1705


FUNCTION and DESCRIPTIONMain Pump (<strong>P1</strong>) function:The pump is running:- when the collector temperature (<strong>T1</strong>) is above the Tank temperature (<strong>T2</strong>) + dt, adjustable on the parameter menu(N°1=>default value 8°C)- during 15 seconds if the pump doesn’t work during 5 days. (Antilock braking function)The pump is turned off:- when the collector temperature (<strong>T1</strong>) decrease under the Tank temperature (<strong>T2</strong>) + dt/2.Example:dt Settingdt Setting / 2dt = <strong>T1</strong>- <strong>T2</strong>P 1Additional heat (<strong>P2</strong>) Extra function:dt (°C)To use this option you must connect the extra sensor <strong>T3</strong>.This output is generally used to control an additional heat on your tank (Electrical résistance or boiler…)Switch on:- When the water temperature (<strong>T3</strong>) inside the tank decrease under the setting level, adjustable on the parametermenu (N°3 =>default value 50°C)Switch off:- When the water temperature (<strong>T3</strong>) is 5°C above the setting level.Example:<strong>T3</strong> setting + 5°C<strong>T3</strong> settingWater temperature in tank <strong>T3</strong> (°C)P3Cooling (<strong>P2</strong>) Extra function:The cooling function is generally used for cooling down the primary solar tank at high solar irradiation. With this functionyou could cumulate excess energy on another heat storage. (Swimming pool, tank …)Switch on:- When the water temperature (<strong>T3</strong>) inside the tank increase upper the setting level, adjustable on the parameter menu(N°3 =>default value 50°C)Switch off:- When the water temperature (<strong>T3</strong>) is 5°C below the setting level.Example:Water temperature in tank <strong>T3</strong> (°C)Panel and system protections:Freeze and snow protectionThis option will keep the solar panel temperature <strong>T1</strong> above the Freeze setting (adjustable on theparameters menu N°4) by activating the pump <strong>P1</strong>.This option could be used to reduce snow accumulation on the panel and increases the efficiency duringthe day or to avoid the solar liquid damages.Be Careful: it is preferable not to use this function in the too cold regions in order not to use too much theenergy stored in the tank.Panel overheat protectionThis option is used to protect the collector liquid.It consists to activate the pump if temperature on the collector <strong>T1</strong> exceeds the value of parameter N°6(default value 140°C), even if the max temperature is reach. (The pump will be stopped when the watertemperature in the tank will reach 95°C).System overheat protectionIf the temperature in the tank is 95°C (Max admissible temperature) and the collector temperature <strong>T1</strong> is 5°Cbelow. The pump will be activated to cool the tank until the adjusted value (parameter n°2).You can deactivate this function on the parameters menu (N°5 = default value off)Sensors error:Collector sensor (<strong>T1</strong>): The pump <strong>P1</strong> is stopped (Err 1 and concerning LED blinks).Tank sensor (<strong>T2</strong>):The pump <strong>P1</strong> is stopped (Err 2 and concerning LED blinks).Extra sensor (<strong>T3</strong>): The additional heat is stopped. (Err 3)Corresponding value for sensor P<strong>T1</strong>000: (To be check with an Ohmmeter)-10°C0°C960 ohms1000 ohms60°C70°C1232 ohms1271 ohms10°C20°C30°C1039 ohms1077 ohms1116 ohms80°C90°C100°C1309 ohms1347 ohms1385 ohms40°C 1155 ohms 120°C 1461 ohms50°C 1194 ohms 140°C 1535 ohmsPARAMETERS MENUPress and during 2 seconds to enter on the parameters menu.After, Press to select the parameter to modify with or .Parameter N°1 = dtDifference between collector temperature (<strong>T1</strong>) and Tank temperature (<strong>T2</strong>) to start the mainpump. (Default value 8°C)Parameter N°2 = Max temperature<strong>T3</strong> setting<strong>T3</strong> setting – 5°CP3Max desired water temperature on the Tank. (Default value is 90°C)Parameter N°3 = Set Level for Additional HeatSetting level to start the additional heat. (Default value 50°C)Effective only if <strong>T3</strong> sensor is connected


Parametr N°4 = Zabezpieczenie przeciwzamrożenioweZabezpieczenie przeciwzamrożeniowe jest nieaktywne. (nastawa fabryczna)InstrukcjaSterownik Basic Solar control<strong>T1</strong>Zmiana nastawy aktywuje zabezpieczenie. (zakres nastawy:od -5 do 5°C)Parametr N°5 = Zabezpieczenie przed przegrzewem instalacjiZabezpieczenie przed przegrzewem jest nieaktywne. (nastawa fabryczna)Zabezpieczenie jest aktywne.Parametrr N°6 = Maksymalna temperatura kolektora<strong>P1</strong>Funkcja dodatkowa:-kontrola dodatkowegoźródła ciepła,- sensor <strong>T3</strong><strong>T3</strong><strong>P2</strong>Zmiana nastawy aktywuje zabezpieczenie przed przegrzewemkolektora (wartość fabryczna 140°C) . Zakres nastawy od 100°C(10)do 200°C (20)Parameter N°7 = Definiowanie orurowania kolektoraSystem pracuje z zastosowaniem standardowego kolektora panelowego. (nastawafabryczna)System pracuje z zastosowaniem kolektora rurowego (Próżniowy kolektor rurowy).W interwałach 30 minutowych uruchomiona zostaje pompa na okres 30 s. w celuwyrównania temperatur i uzyskania prawidłowego pomiaru. Ten cykl pracy chroni systemprzed krótkotrwałymi załączeniami i pulsacyjnymi doładowaniami zasobnika.Parametr N°8 = Dodatkowa funkcja dla pompy <strong>P2</strong> (działa tylko jeśli czujnik <strong>T3</strong> jest podłączony )Wyjście <strong>P2</strong> jest stosowane do kontroli ciepła dostarczanego ze źródła dodatkowego.(nastawa domyślna - wyłączone)Wyjście <strong>P2</strong> jest stosowane do chłodzenia zasobnika lub innego akumulatora ciepła.Parametr N°<strong>P1</strong> = Test pompy głównej (Nastawa fabryczna <strong>P1</strong>:A)<strong>T2</strong>CHARAKTERYSTYKA TECHNICZNAZakres temperatur pracy 0°C - 50°CZakres nastaw temperatury:Dt (Różnica temp. - kolektor <strong>T1</strong>/ zasobnik <strong>T2</strong>)4°C - 30°C (39°F - 86°F)Temperatura wody ( temperatura w zasobniku <strong>T2</strong>)30°C - 90°C (86°F - 194°F)Temp. dodatkowego źródła (Nastawa dla <strong>P2</strong>)0°C - 85°C (0°F – 185°F)Klasa obudowyIP42Zasilanie230Vac +/- 10% 50HzWyjścia:<strong>P1</strong> (Pompa główna):<strong>P2</strong> (Funkcja dodatkowa):Czujnik:<strong>T1</strong> (Kolektor):<strong>T2</strong> (Zbiornik/Zasobnik):<strong>T3</strong> (Dodatkowy czujnik do sterowania <strong>P2</strong>):Wersja oprogramowaniaWYŚWIETLACZPrzekaźnik 8A 250VAC.Przekaźnik 8A 250VACPT 1000 (1,5 metra, Max 180°C)PT 1000 (3 metry, Max 105°C)PT 1000 (3 metry, Max 105°C)Wersja jest wyświetlana w trakcieuruchamiania U 1._Tryb automatyczny: Pompa pracuje zgodnie z wartością “dt” value.Tryb ręczny: Pompa pracuje przez 4 godziny i po tym okresie wraca do Trybuautomatycznego.Tryb ręczny: Pompa wyłączona.Parametr N°<strong>P2</strong> = Test wyjścia dodatkowego (działa jeśli <strong>T3</strong> jest podłączony)Tryb ręczny: Dodatkowe żródło ciepła jest załączone.Tryb ręczny: Dodatkowe żródło ciepła jest wyłączone.1: Wskaźnik temperatury na dnie zbiornika(Wyświetlacz “7” pokazuje mierzoną temp.).2: Wskaźnik stanu pompy(pulsuje w trakcie pracy)3: Wskaźnik stan dodatkowego źródła(pulsuje w trakcie pracy)4: Max temperatura w zbiorniku (nastawa).5: dt różnica temperatur pomiędzy kolektorem ”6” izbiornikiem ”1”. (nastawa)6: Wskaźnik temperatury w kolektorze (Wyświetlacz “7”pokazuje mierzoną wartość). 57: Wyświetlacz(czerwony).4 3A: Minus (zmniejszanie wartości)B: Menu (zmiana wskazania i numeruparametru)C: Plus (zwiększanie wartości)26 71A B CPPL IMP 1705


ALGORYTM PRACY STEROWNIKAFunkcje pompy głównej (<strong>P1</strong>):Pompa pracuje:- gdy temperatura kolektora (<strong>T1</strong>) jest wyższa od temperatury zbiornika (<strong>T2</strong>) + wartość dt - ustawialny parametr wmenu (N°1=>wartość fabryczna 8°C)- gdy nastąpił przestój 5 dniowy. Pompa uruchamiana jest na 15 sekund. (Ochrona przed zablokowaniem pompy)Pompa jest wyłączona :- gdy temperatura kolektora(<strong>T1</strong>) spada poniżej temperatury zbiornika (<strong>T2</strong>) + wartość dt/2.Przykład:dt / 2dtdt = <strong>T1</strong>- <strong>T2</strong>P 1dt (°C)Funkcja dodatkowa (<strong>P2</strong>) – dodatkowe źródło ciepła:Funkcja jest aktywna po podłączeniu czujnika <strong>T3</strong>.To wyjście służy do sterowania pracą dodatkowego źródła ciepła (np.grzałka elektryczna , kocioł na paliwastałe…)Wyjście załączone:- Gdy temperatura wody (<strong>T3</strong>) wewnątrz zbiornika spada poniżej nastawy, która jest nastawiana w menuparametrów (N°3 =>wartość domyślna 50°C)Wyjście wyłączone:- Gdy temperatura wody (<strong>T3</strong>) jest o 5°C powyżej nastawy.Przykład:nastawa<strong>T3</strong>+5°Cnastawa<strong>T3</strong>Temperatura wody <strong>T3</strong> (°C)P3Funkcja dodatkowa (<strong>P2</strong>) - Chłodzenie:W przypadkach wysokiego nasłonecznienia skutkującego wysokimi temperaturami w pierwotnym obiegu solarnymzachodzi potrzeba chłodzenia układu. Dodatkowe ciepło odebrane w tym procesie może zostać przekazane dokolejnego akumulatora ciepła lub wykorzystane do dodatkowego ogrzewania . ( np. podgrzewanie wody basenowej)Wyjście załączone:- Gdy temperatura wody (<strong>T3</strong>) wewnątrz zbiornika wzrasta powyżej nastawy , która jest ustawiana w menu parametrów(N°3 =>wartość domyślna 50°C)Wyjście wyłączone:- Gdy temperatura wody (<strong>T3</strong>) jest o 5°C poniżej nastawy.Przykład:Nastawa <strong>T3</strong>Temperatura wody w zbiorniku <strong>T3</strong> (°C)Zabezpieczenia instalacji:Odtajanie i ochrona przeciwzamrożeniowaTa funkcja umożliwia utrzymywanie temperatury panela solarnego <strong>T1</strong> powyżej nastawyprzeciwzamrożeniowej (ustawianej parametrem N°4) dzięki załączeniu pompy <strong>P1</strong>.Stosuje się ją w celu stopienia śniegu zgromadzonego na panelu oraz w celu ochrony przedpotencjalnymi zniszczeniami spowodowanymi przez płyn roboczy.Uwaga:Stosowanie tej funkcji w zimnych strefach klimatycznych znacząco wpływa na zużycie energiicieplnej zgromadzonej w zbiorniku.Ochrona panela przed przegrzaniemFunkcja stosowana w celu zabezpieczenia płynu roboczego w panelu solarnym.Jeśli temperatura kolektora <strong>T1</strong> przekracza wartość nastawy parametru N°6 (wartość domyślna140°C),to uruchamiana jest pompa , nawet jeśli temperatura wody w zbiorniku została osiągnięta(pompa będzie pracowała do osiągnięcia temperatury 95°C w zbiorniku).Ochrona instalacji przed przegrzaniemJeśli temperatura w zbiorniku osiągnie 95°C (Max dopuszczalna temp.) a temperature kolektora <strong>T1</strong> jest o 5°Cniższa to nastąpi uruchomienie pompy w celu wychłodzenia zbiornika do wartości nastawianej w menuparametrów (parametr n°2).Funkcja może zostać wyłączona w menu parametrów (N°5 = wartość domyślna -wyłączone)Błędy czujników:Czujnik kolektora (<strong>T1</strong>): Pompa <strong>P1</strong> zatrzymana (Err 1 oraz migająca dioda LED ).Czujnik zbiornika (<strong>T2</strong>): Pompa <strong>P1</strong> zatrzymana (Err 2 oraz migająca dioda LED).Czujnik dodatkowy (<strong>T3</strong>): Dodatkowe żródło ciepła wyłączone. (Err 3)Wartości oporu dla czujnika P<strong>T1</strong>000: (Sprawdzić miernikiem oporu)-10°C0°C960 Ω1000 Ω60°C70°C1232 Ω1271 Ω10°C20°C30°C1039 Ω1077 Ω1116 Ω80°C90°C100°C1309 Ω1347 Ω1385 Ω40°C 1155 Ω 120°C 1461 Ω50°C 1194 Ω 140°C 1535 ΩMENU PARAMETRÓWNaciśnij i przez 2 sekundy aby wejść do menu parametrów.Nacisnąć aby wybrać parametr; zmiana wartości lub .Parametr N°1 = dtRóżnica pomiędzy temperaturą kolektora (<strong>T1</strong>) a temperaturą zbiornika (<strong>T2</strong>) umożliwiającauruchomienie pompy. (Wartość domyślna 8°C)Parametr N°2 = Maksymalna temperaturaMaksymalna temperatura wody w zbiorniku. (Domyślnie 90°C)Parametr N°3 = Temperatura uruchomienia dodatkowego źródła ciepłaNastawa<strong>T3</strong> – 5°CP3Nastawa załączająca dodatkowe źródło ciepła. (Domyślnie50°C). Funkcja aktywna jeśli czujnik <strong>T3</strong> jest podłączony