DemonstrationTestAnalysisExamination/InspectionQualify by SimilarityGlobal Broadcast Service (GBS)Volume VI – Model Contract – Attachment 3<strong>SRD</strong> IDRequirement470004710047200The RBM to End User Interface shall allow the RBM to deliver various files andstreaming products to end users using standard internet protocols that include, but arenot limitedto: Hyper Text Transfer Protocol (HTTP), Hyper Text Transfer Protocol Secure(HTTPS), File Transfer Protocol (FTP), File Transfer Protocol over Secure SocketsLayer (FTPS), SSH File Transfer Protocol (SFTP), Real-Time Transport Protocol(RTP), Internet Group Management Protocol (IGMP), Session Description Protocol(SDP), Trivial File Transfer Protocol (TFTP), and Multicast. [<strong>SRD</strong> ID 47000]The RBM to End User Interface shall allow the End User access to the RBM by usingHTTPS. [<strong>SRD</strong> ID 47100]The RBM to SBM interface shall allow RBM feedback across the DISN using HTTPSwith DOD PKI certificates. [<strong>SRD</strong> ID 47200]xxx48000The GBS transport system shall provide capabilities that ensure that informationidentified as priority is delivered ahead of regular traffic 99% of the time. [<strong>SRD</strong> ID48000]x484004850048600487004880048900500005010150102Each LRU element of the GBS system shall include Built-In-Test (BIT) diagnosticsthat fault isolate using contractor supplied test equipment, 95% of the time. [<strong>SRD</strong> ID48400]The SBM Mean Time to Repair (unscheduled maintenance) shall be less than 90minutes. [<strong>SRD</strong> ID 48500]SBM operator level maintenance shall be limited to basic care, cleaning, andreplacement of expendables and Line Replaceable Units (LRU). [<strong>SRD</strong> ID 48600]SBM scheduled routine maintenance shall be performed without disruption to serviceoperations. [<strong>SRD</strong> ID 48700]SBM scheduled and routine maintenance time shall not exceed one maintenance hourper 24-hour period. [<strong>SRD</strong> ID 48800]The GBS system shall allow cryptographic equipment to be maintained and repaired inaccordance with COMSEC maintenance policies and procedures. [<strong>SRD</strong> ID 48900]The RBM Mean Time to Repair (unscheduled maintenance) shall be less than 90minutes. [<strong>SRD</strong> ID 50000]The SBM shall maintain an operational availability of 99.0% over a period of 480hours. [<strong>SRD</strong> ID 50101]The SBM shall maintain an operational availability of 99.99% over a period of 480hours. (Objective) [<strong>SRD</strong> ID 50102]xxxxxxxx50201Fixed Sites and Equipment exposed directly to an external environment shall operatein blowing sand, dust, and all precipitation environments during 45 mph sustainedwinds, gusts to 60 mph in -40°F to 120°F air temperatures plus solar loading at allhumidity levels. (Threshold) [<strong>SRD</strong> ID 50201]x5020250400Fixed Sites and Equipment exposed directly to an external environment shall operatein blowing sand, dust, and all precipitation environments during 45 mph sustainedwinds, gusts to 60 mph in -50°F to 150°F air temperatures plus solar loading at allhumidity levels. [<strong>SRD</strong> ID 50202]The broadcast segment shall be capable of operating at 120/220 VAC at 60/50 Hzpower. [<strong>SRD</strong> ID 50400]xx30 March 2009 • Contract Number: FA8726-09-C-0006Use or disclosure of data contained on this sheet is subject to the restriction on the title page of this proposalVolume VI-5.0-166

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!