13.07.2015 Views

evapo-rust rust remover

evapo-rust rust remover

evapo-rust rust remover

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Material Safety Data SheetE-Z Safe Solutions EVAPO-RUSTProduct Hazard: Health: 0 Fire: 0 Toxicity: 0 Reactivity: 0 Special: 0Hazard Rating:4 = Deadly 3 = Extreme 2 = Hazardous 1= Slight Hazard 0 = Normal1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING 01/03/07Product Name:EVAPO-RUSTManufacturer/Supplier:Orison Marketing, L.L.C. (Cage Code: 1GZV7)4801 South Danville DriveAbilene, TX 79602Emergency Telephone Number:(325) 692-1135 or 800-460-2403 (in the U.S.)2. INGREDIENTSContains no hazardous components under current OSHA definitions.*These chemicals are subject to reporting requirements off section 313 of the Emergency Planning and Right-To-Know Act of 1986 and of40 CFR 372.3. HAZARDS IDENTIFICATIONCarcinogen: NA NTP: NA IARC Monograph: NA OSHA: NAPrimary Routes of Entry: Eye – Yes Ingestion – Yes Inhalation – NA Skin - YesEffects of overexposure: Eye – none Ingestion – nausea Inhalation – none Skin - noneMost Important Hazards:Specific Hazards:NoneNone4. FIRST AID MEASURESGeneral Advice:Inhalation:Skin Contact:Eye Contact:Ingestion:5. FIRE-FIGHTING MEASURESSuitable Extinguishing Media:Special Fire Fighting Procedures:Specific Hazards:Flash Point:6. ACCIDENTAL RELEASE MEASURESPersonal Precautions:Environmental Precautions:Methods for Cleaning Up:Product exhibits no adverse effects.Non-reactive – No First Aid needed.Not a skin irritant, PDII = 0.9. Not dermally toxic, LD50> 2,000 mg/kg.Not an eye irritant, MMTS = 0.0.. Rinse thoroughly with plenty of water.Product is non-toxic. Evapo-Rust tested to be non-toxic when orally dosed at aconcentration of 5 g/kg in rats. If necessary, give victim two glasses of water andINDUCE VOMITING by using ipecac syrup or placing two fingers at the back of thethroat. Get immediate attention. Do not give anything by mouth to an unconsciousperson.Dry chemical, CO2Wear SCBA & all protective equipmentNoneNoneNone needed. Caution floor may be slippery.None needed; non-toxic, non-hazardous in neat form.Filter and reuse or dispose directly by flushing area with water into sewer.www.orisonllc.com * info@orisonllc.com * Cage Code: 1GZV7 * 800.460.2403


SAFETY DATA SHEET Page: 2 of 2PRODUCT: EVAPO-RUST Revision Date: 01/03/077. HANDLING AND STORAGECorrosivity:Non-corrosive.Technical Measures/Precautions:Normal ventilation is adequate.Safe Handling Advice:Avoid contact with eyes.Technical Measures/Storage Conditions:Incompatible Products:Packaging Material:8. EXPOSURE CONTROLS/PERSONAL PROTECTIONEngineering Measures:Control Parameters:Personal Protection EquipmentRespiratory:Eye:Hand:Hygiene Measures:Low temperature can cause handling problems. Viscosity of material will increase.No special restrictions on storage with other products.No restrictions.General room ventilation is satisfactory.None needed.None needed.Not an eye irritant, MMTS = 0.0. Safety glasses may be used.Not a skin irritant, PDII = 0.9. Not dermally toxic, LD50> 2,000 mg/kg. Gloves canhelp retain natural moisture.Employ good hygiene measures.9. PHYSICAL AND CHEMICAL PROPERTIESForm: Water viscous liquidColor: Light amber to yellowOdor: Slight/Pleasant odor pH: 5.7 – 6.3Boiling Point/Range: >200°FMelting Point/Range: Not ApplicableFreezing Point: 32°F/0°CViscosity @ 25°C: same as waterFlash Point: NoneExplosive Properties: None% Volatile by weight: >85% Water Solubility: CompleteVapor Pressure: NA Vapor Density: NA air =1Surface Tension: Not determined Specific Gravity: 1.036 – 1.042Evaporation Rate: >1 ether=1 (same as water) Volatile Organic Compounds: None known10. STABILITY AND REACTIVITYStability:Conditions to Avoid:Materials to Avoid:Hazardous Decomposition Products:Hazardous Polymerization:Normally StableHigh temperaturesAvoid contact with strong oxidizing agents or other reactive materials.Oxides of carbonWill not occur11. TOXICOLOGICAL INFORMATIONAcute Toxicity: Non-toxic. Evapo-Rust tested to be non-toxic when orally dosed at a concentration of 5 g/kg in rats. None of the testanimals showed any adverse affects to the test article. At the study’s completion, all rats were necropsied and each animalappeared normal for gross pathology.Local Effects:None.Specific Effects:None.12. ECOLOGICAL INFORMATIONNon-toxic, non-hazardous, safe for the environment.13. DISPOSAL CONSIDERATIONSWaste from Residues/Unused Products: Non-hazardous. Sewerable in neat form. Product container is recyclable.Contaminated Packaging: If recycling is not practicable, dispose of in compliance with the Environmental Protection (Duty of Care)Regulations 1991 if contaminated with hazardous materials. May be disposed of in neat form.14. TRANSPORTATION INFORMATIONNot classified as dangerous or hazardous in the meaning of transport regulations.15. REGULATORY INFORMATIONProduct complies with all known regulatory considerations and is unregulated and not listed as a Hazmat by any agency.16. OTHER INFORMATIONFor further information, contact the Headquarters of Orison Marketing, L.L.C.Recommended Use:Rust RemoverThe information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given isdesigned only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification.The information relates only to the specific material designated and is not valid for such material used in combination with any other materials or in any process, unlessspecified in the text.www.orisonllc.com * info@orisonllc.com * Cage Code: 1GZV7 * 800.460.2403

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!