Bulletin HY14-2597-B1/USPerformance Curves<strong>Proportional</strong> <strong>Directional</strong> <strong>Control</strong> <strong>Valves</strong>Series D*FWFlowGPM5.34.0LPM20152.6 101.3 5atD1FW Flow Characteristicsp = 5 Bar (72.5 PSI) / metering edgeFlowCode HFlowCode FFlowCode CFlowGPM LPM15.9 6013.2 5010.6 407.9 305.3 20atD3FW Flow Characteristicsp = 5 Bar (72.5 PSI) / metering edgeP A : B T; or P B : A TFlowCode SFlowCode MFlowCode H00 20 40 60 80 100Command Signal (%)2.6 1000 20 40 60 80 100Command Signal (%)GPM LPM14 53Flow1210864245383023158FlowCode FFlowCode CD1FW Operating Limitsat 100% Nominal CurrentP A : B T; or P B : A TFlowCode HFlowGPM LPM50 18945 17040 15135 13330 11425 9520 7615 5710 385 19D3FW Operating Limitsat 100% Nominal CurrentP A : B T; or P B : A TFlowCode MFlowCode HFlowCode S0Bar0PSI691000138 2072000 3000Pressure Drop27640000Bar0PSI691000138 2072000 3000Pressure Drop27640002597-b1.p65, dd, bmHydraulics 2Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA