13.07.2015 Views

FWBSeries

FWBSeries

FWBSeries

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GFWB SeriesHow to orderManifoldG F W B 2 1 Z 3 0 2C 1Manifold with masking plateG F W B 3 1 5 X D 2G 2 5 2Model no.HNB/GUSB/GFAB/GNo. of port(2 port valve)Working fluid(Water)A Size variationB Circuit structureGFWB21-Z-3-02C-1Model: GFWBNote on model no. selectionC OrificeD Station no.*1*2E Body, sealant combinationF Coil option*3*4A Size variation : 22 mmB Circuit structure : NC (normally closed) / common water supply typeC Orifice : 1D Station no. : 3 stationsE Body, sealant combinationG Voltage: Body - brass, sealant - NBR*5F Coil option : Grommet lead wireG Voltage : 100 VAC 50/60Hz, 110 VAC 60HzH I: No masking plate*1: For the number of manifold stations, select a number of stations from 2 to 10.*2: For the type with masking plate, designate the item (D) as "X", then designatethe number of (H) solenoid valves and (I) masking plates.*3: For GFWB21 item (F) 2G and 2HS, the compact terminal box (Pg9) is used.*4: For item (F) 2CS, the surge suppressor is built into the coil, and for 2HS and3RS, it is built into the terminal box.*5: Consult with CKD for other voltages that cannot be manufactured.*6: Solenoid valves are arranged from the right side facing the sub-plate A(independent) port.*7: Orders for only the masking plate and sub-plate are also available. ContactCKD for details.H Solenoidvalve quantity*6I MaskingSymbol DescriptionsA Size variation2 22 mm3 28 mm4 34 mm5 40 mmB Circuit structure1C OrificeZ23567F Coil option2C Standard2CS2G2HS2CG2CH3T3RS1234NC (normally closed) / common water supply typeD Station no.2 2 stationsto to10 10 stationsO Actuator onlyX With masking plateE Body, sealant combinationBody SealantO BrassNBRD Stainless steel NBROption123457G VoltageGrommet lead wireGrommet lead wire withsurge suppressorDIN terminal box (Pg11)DIN terminal box with lightand surge suppressor (Pg11)Conduit (CTC19)Conduit (G1/2)T type terminal box (G1/2)T type terminal box with lightand surge suppressor (G1/2)100 VAC 50/60Hz, 110 VAC 60Hz200 VAC 50/60Hz, 220 VAC 60Hz24 VDC12 VDCGFWB21GFWB31G GF FWBWB41 51For voltages other than the above, write in the voltage directly.H Solenoid valve quantityBlank No masking plate1 One solenoid valveto to9 Nine solenoid valvesI Masking plate quantityBlank No masking plate1 One masking plateto to9 Nine masking platesSelect from the combination of marks in the above table.85FGB/GFVBFWB/GFHBFLBABAGAP/ADAPK/ADKFordry airExplosionproofHVB/HVLSAB/SVBNP/NAP/NVPCHB/GMXB/GOther G.P.systemsPD/FAD/PJCVE/CVSECPE/CPDMedicalanalysisCustomorderSpecial purpose valve for waterDirect acting 2 port solenoid valve

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!