13.07.2015 Views

FWBSeries

FWBSeries

FWBSeries

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GFWG SeriesHow to orderManifoldG F W G 2 1 Z 5 0 2C 1Manifold with masking plateG F W G 3 1 4 X D 2G 2 3 6HNB/GUSB/GFAB/GNo. of port(3 port valve)Working fluid(Water)A Size variationB Circuit structureGFWG21-Z-5-02C-1Model: GFWGC OrificeD Station no.*1*2E Body, sealant combinationF Coil option*3*4A Size variation : 22 mmB Circuit structure: Common water supply / individual drain typeC Orifice : 1G VoltageD Station no. : 5 stations*5E Body, sealant combination: Body - brass, sealant - NBRF Coil option : Grommet lead wireG Voltage : 100 VAC 50/60Hz, 110 VAC 60HzH I: No masking plateNote on model no. selectionH Solenoidvalve quantity*6SymbolDescriptionsA Size variation2 22 mm3 28 mm4 34 mm5 40 mmB Circuit structure1 Common water supply / individual drain typeC OrificeD Station no.2 2 stationsto to10 10 stationsO Actuator onlyX With masking plateF Coil option2C Standard2CS2G2HS*1: For the number of manifold stations, select a number of stations from 2 to 10.*2: For the type with masking plate, designate the item (D) as "X", then designate the9 Nine solenoid valvesnumber of (H) solenoid valves and (I) masking plates.I Masking plate quantity*3: For GFWG21 item (F) 2G and 2HS, the compact terminal box (Pg9) is used. I Masking*4: For item (F) 2CS, the surge suppressor is built into the coil, and for 2HS and 3RS,Blank No masking plateplate quantityit is built into the terminal box.1 One masking plate*5: Consult with CKD for other voltages that cannot be manufactured.to to*6: Solenoid valves are arranged from the right side facing the sub-plate A (independent) port.*7: Orders for only the masking plate and sub-plate are also available. Contact CKD for details.9 Nine masking platesSelect from the combination of marks in the above table.EZO14Body, sealant combinationBodyBrassStainless steelOD2CG2CH3T3RSOption11.523Grommet lead wireGrommet lead wire withsurge suppressorDIN terminal box (Pg11)DIN terminal box with lightand surge suppressor (Pg11)Conduit (CTC19)Conduit (G1/2)T type terminal box (G1/2)T type terminal box with lightand surge suppressor (G1/2)H Solenoid valve quantityBlank No masking plate1 One solenoid valveto toSealantNBRNBRModel no.G G G GF F F FW W W WG G G G21 31 41 51G Voltage1 100 VAC 50/60Hz, 110 VAC 60Hz2 200 VAC 50/60Hz, 220 VAC 60Hz3 24 VDC4 12 VDCFor voltages other than the above, write in the voltage directly.95FGB/GFVBFWB/GFHBFLBABAGAP/ADAPK/ADKFordry airExplosionproofHVB/HVLSAB/SVBNP/NAP/NVPCHB/GMXB/GOther G.P.systemsPD/FAD/PJCVE/CVSECPE/CPDMedicalanalysisCustomorderSpecial purpose valve for waterDirect acting 3 port solenoid valve

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!